Issue 7, 2015

Transient signal isotope analysis using multicollection of ion beams with Faraday cups equipped with 1012 Ω and 1011 Ω feedback resistors

Abstract

To improve the precision of isotope analyses of low ion intensities using the Faraday detection system, amplifiers equipped with 1012 Ω resistors (hereafter 1012 Ω amplifiers) have been developed. While the behavior of these amplifiers for steady signals has been well investigated, there is no ample evidence regarding the use of 1012 Ω amplifiers for transient signal acquisition. In this work, we investigated the simultaneous use of amplifiers equipped with 1012 Ω and 1011 Ω resistors for transient signal acquisition. Using the equation describing the relationship between the input ion current and the output voltage in the amplifiers, we showed how the transient signal duration influences the accuracy of the isotope ratio measurements. In particular, lead transient signals were investigated using a Neptune Plus MC-ICPMS and 204Pb and 206Pb isotopes were measured using 1012 Ω and 1011 Ω amplifiers, respectively. The 204Pb/206Pb isotope ratio showed an important drift due to a large time lag between 1012 Ω and 1011 Ω amplifiers. The time lag was quantified (0.175(3) s) and the isotopic drift was corrected using a method of internal signal synchronization. The 204Pb/206Pb drift corrected data obtained from the 1012–1011 Ω amplifier configuration were compared to the data obtained from 1011–1011 Ω amplifiers. Our results point out that for low transient signal intensities (<10−13 A), the use of 1012–1011 Ω amplifiers is more beneficial in terms of isotope ratio uncertainty, repeatability and trueness, compared to the 1011–1011 Ω amplifier configuration.

Graphical abstract: Transient signal isotope analysis using multicollection of ion beams with Faraday cups equipped with 1012 Ω and 1011 Ω feedback resistors

Article information

Article type
Paper
Submitted
20 Mar 2015
Accepted
21 Apr 2015
First published
21 Apr 2015

J. Anal. At. Spectrom., 2015,30, 1582-1589

Author version available

Transient signal isotope analysis using multicollection of ion beams with Faraday cups equipped with 1012 Ω and 1011 Ω feedback resistors

A. Gourgiotis, G. Manhès, P. Louvat, J. Moureau and J. Gaillardet, J. Anal. At. Spectrom., 2015, 30, 1582 DOI: 10.1039/C5JA00094G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.