Issue 4, 2015

Malaria detection using inertial microfluidics

Abstract

Diagnosis of malaria at the early stage of infection is challenging due to the difficulty in detecting low abundance parasites from blood. Molecular methods such as real-time polymerase chain reaction (qPCR) can be especially useful for detecting low parasitemia levels due to their high sensitivity and their ability to recognize different malarial species and strains. Unfortunately, the accuracy of qPCR-based malaria detection can be compromised by many factors, including the limited specificity of primers, presence of PCR inhibitors in blood serum and DNA contamination from nucleated blood cells. Here, we use a label-free, shear-modulated inertial microfluidic system to enrich malaria parasites from blood so as to facilitate a more reliable and specific PCR-based malaria detection. This technique capitalizes on cell focusing behaviors in high aspect ratio microchannels coupled with pinched flow dynamics to isolate ring-stage malaria parasites from lysed blood containing white blood cells (WBCs). In this high aspect ratio (ratio of the channel height to the width) platform, the high shear rate along the channel width causes the dispersed WBCs at the inlet to migrate and align into two streams near the channel sidewalls while the malaria parasites remain unfocused. Sensitive detection of parasites at spiked densities ranging from 103 to 104Plasmodium falciparum parasites per mL (~2–10 per μL) has been demonstrated; they have also been quantified in whole blood using qPCR. This is approximately 100-fold more sensitive than the gold standard conventional microscopy analysis of thick blood smears. The simplicity of this device makes it ideal for integration with an automatic system for ultra-fast and accurate detection despite low levels of parasitemia. It can also help in malaria screening and elimination efforts.

Graphical abstract: Malaria detection using inertial microfluidics

Supplementary files

Article information

Article type
Paper
Submitted
09 Sep 2014
Accepted
02 Dec 2014
First published
05 Dec 2014

Lab Chip, 2015,15, 1101-1109

Author version available

Malaria detection using inertial microfluidics

M. E. Warkiani, A. K. P. Tay, B. L. Khoo, X. Xiaofeng, J. Han and C. T. Lim, Lab Chip, 2015, 15, 1101 DOI: 10.1039/C4LC01058B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements