Issue 109, 2015

Study of mean diameter and drop size distribution of emulsion drops in a modified rotating disc contactor for an emulsion liquid membrane system

Abstract

To improve the dispersity of the emulsion phase in an emulsion liquid membrane (ELM) system, a modified rotating disc contactor (MRDC) was developed. Then, the Sauter mean diameter (d32) of emulsion drops and their drop size distribution were measured by photographic method and analyzed by an image processing program in MATLAB. The effects of rotating speed, flow ratio, total flow, stirring paddle width and surfactant concentration on the drop size and its distribution were studied. The results show that, with the increase in the rotating speed and the paddle width, the degree of turbulence was enhanced which led to the reduction in the drop size. Meanwhile, membrane breakage increased with the turbulent fluctuation, which resulted in the leakage of the internal phase. Fortunately, the membrane breakage could be prevented by a suitable increase in the surfactant concentration. In addition, the drop size decreased with the increase in the surfactant concentration. Besides, the increase in the emulsion phase flow obviously increased the drop size, whereas the increase in the continuous phase flow induced the entrainment of small drops. An empirical correlation for the prediction of the d32 was established with an average absolute relative error (AARE) of 4.1%. The drop size distribution based on the drop volume was accurately fitted with a normal distribution, and its probability density function parameters (α and β) were well predicted by the dimensionless correlations, with the AAREs of 4.2% and 5.9%, respectively.

Graphical abstract: Study of mean diameter and drop size distribution of emulsion drops in a modified rotating disc contactor for an emulsion liquid membrane system

Article information

Article type
Paper
Submitted
12 Aug 2015
Accepted
15 Oct 2015
First published
15 Oct 2015

RSC Adv., 2015,5, 89959-89970

Author version available

Study of mean diameter and drop size distribution of emulsion drops in a modified rotating disc contactor for an emulsion liquid membrane system

L. Zeng, Y. Zhang, C. Bukirwa, W. Li and Y. Yang, RSC Adv., 2015, 5, 89959 DOI: 10.1039/C5RA16267J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements