Issue 3, 2016

Real-time monitoring of contractile properties of H9C2 cardiomyoblasts by using a quartz crystal microbalance

Abstract

Conventional cardiac physiology experiments investigate in vitro beat frequency using cells isolated from adult or neonatal rat hearts. Recently, there is an increased interest in measuring the mechanical properties of cardiomyocytes including their contraction force and viscoelasticity. In this study, we used a quartz crystal microbalance (QCM) to study the viscoelasticity of populations of H9C2 cardiomyoblasts under different stimuli. First, we observed the effects of osmotic pressure and found that H9C2 cardiomyoblasts became stiffer under hypertonic conditions and softer under hypotonic conditions. Then we compared the effects of two inotropic cardiovascular drugs, and found that the positive inotropic drug, isoprenaline (ISO), made H9C2 cells stiffer and the negative inotropic drug, verapamil (VRP), made cells softer. For the dosage ranges tested for ISO (12.5–125 nM) and VRP (12.5–250 nM), we also observed that the higher the ISO concentration, the stiffer were the cells; and the higher the VRP concentration, the softer were the cells. Although H9C2 cardiomyoblasts do not have the beating function, our results showed that they still have the ability to contract and expand. Moreover, they are homogeneous and immortal, making them a potentially suitable cell model for the study of contraction and relaxation characteristics of cardiomyocytes, and for pre-assessment and toxicity testing of cardiovascular drugs where high-throughput and repetitions are required. In addition, we demonstrated that the QCM is a potentially useful tool for assessing the contractility of populations of cardiomyocytes.

Graphical abstract: Real-time monitoring of contractile properties of H9C2 cardiomyoblasts by using a quartz crystal microbalance

Article information

Article type
Paper
Submitted
27 Oct 2015
Accepted
25 Nov 2015
First published
02 Dec 2015

Anal. Methods, 2016,8, 488-495

Real-time monitoring of contractile properties of H9C2 cardiomyoblasts by using a quartz crystal microbalance

T. Zhou, Z. Zhou, S. Zhou and F. Huang, Anal. Methods, 2016, 8, 488 DOI: 10.1039/C5AY02835C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements