Issue 25, 2016

Response surface methodology based on central composite design as a chemometric tool for optimizing dispersive liquid–liquid microextraction for determining ultra-trace amounts of zinc in oil and water samples

Abstract

The reliable and rapid dispersive liquid–liquid microextraction (DLLME) was applied to highly selective preconcentration and extraction of ultra-trace Zn2+ levels as a prior step to its determination by graphite furnace atomic absorption spectrometry (GFAAS). In this method, N,N-phenylenebis (salicylideaminato) (L) was used as a Zn2+ selective complexing agent. A mixture containing a dispersing solvent (methanol), extraction solvent (chloroform), and proper levels of the chelating agent was rapidly injected into the 5 mL aqueous sample containing 2.5% (w/v) sodium chloride and Zn2+, which resulted in a cloudy solution. After 5 min of centrifuging at 5500 rpm, the fine droplets of extraction solvent were sedimented at the bottom of the conical test tube. The variables of interest in the DLLME method, such as extraction and dispersion solvent types and volumes, sample solution pH, extraction time, chelating agent concentration, and ionic strength, were investigated and optimized using a chemometrics approach. Then, after the preliminary experiment, the factors presenting significant positive effects on the analytical response (pH, salt effect, extraction solvent, and ligand concentration) were considered in a further response surface methodology based on central composite design to optimize the operational conditions for DLLME. It was found that extraction time and common interfering ions had no significant effect on the extraction recovery. Under the selected conditions, the linear range was 0.2–100 ng mL−1 and limit of detection was 0.05 ng mL−1 for most of the analytes. The relative standard deviation (R.S.D) for 2 ng mL−1 Zn2+ was 4.87% (n = 15) and the enrichment factor was 167 from 5 mL of the aqueous sample. In the optimum conditions, the present method was successfully applied to the preconcentration and Zn2+ determination in different natural oil and water samples.

Graphical abstract: Response surface methodology based on central composite design as a chemometric tool for optimizing dispersive liquid–liquid microextraction for determining ultra-trace amounts of zinc in oil and water samples

Article information

Article type
Paper
Submitted
11 Apr 2016
Accepted
28 May 2016
First published
15 Jun 2016

Anal. Methods, 2016,8, 5101-5110

Response surface methodology based on central composite design as a chemometric tool for optimizing dispersive liquid–liquid microextraction for determining ultra-trace amounts of zinc in oil and water samples

E. Khazaeli, H. Haddadi, B. Zargar and A. Hatamie, Anal. Methods, 2016, 8, 5101 DOI: 10.1039/C6AY01068G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.