Issue 7, 2017

A microfluidic detection system for quantitation of copper incorporating a wavelength-ratiometric fluorescent quantum dot pair

Abstract

Described is a new approach to building a microfluidic quantum dot wavelength-ratiometric sensor system for quantifying copper in water and biological samples. This simple-to-use, low-cost, sensitive analytical method has great utility as an indicator and quantitative tool, and we have applied it here with copper as the target analyte. CdTe quantum dots of two different sizes, emitting green and red light, are utilized as fluorophores. The green dot is used as a constant emitter and is encapsulated in a silica shell. The red dot, which is immobilized on the silica surface, is quenched in the presence of copper. The dual emission of the quantum dot wavelength-ratiometric sensor results in a fluorescence color change from red to green, identified visually, corresponding to the absence or the presence of copper. The wavelength-ratiometric sensor is mixed with microcrystalline cellulose and dropcast on a microfluidic chip, made of poly(methyl methacrylate) and assembled using polycaprolactone. Red and green intensity values from the RGB system are used as analytical signals for the calibration curve. Copper in water samples is quantitatively determined by constructing a Stern–Volmer plot in the range of 1–30 mg L−1. For serum samples, absolute values of red and green intensity were plotted to mitigate non-linearity in the Stern–Volmer plot. The microfluidic format of this quantum dot wavelength-ratiometric sensor makes rapid, low-cost testing feasible and convenient for copper detection, directly addressing a diagnostic goal.

Graphical abstract: A microfluidic detection system for quantitation of copper incorporating a wavelength-ratiometric fluorescent quantum dot pair

Supplementary files

Article information

Article type
Paper
Submitted
29 Sep 2016
Accepted
24 Jan 2017
First published
24 Jan 2017

Anal. Methods, 2017,9, 1125-1132

A microfluidic detection system for quantitation of copper incorporating a wavelength-ratiometric fluorescent quantum dot pair

S. Pengpumkiat, Y. Wu, A. Boonloed, G. C. Bandara and V. T. Remcho, Anal. Methods, 2017, 9, 1125 DOI: 10.1039/C6AY02718K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements