Cerebrospinal fluid elemental analysis by using a total sample consumption system operated at high temperature adapted to inductively coupled plasma mass spectrometry

Abstract

A total consumption low sample introduction system has been applied for the first time to the multielement analysis of non-diluted cerebrospinal fluids (CSFs) by means of inductively coupled plasma mass spectrometry (ICP-MS). A 2.5 μL sample volume has been injected into an air carrier stream in agreement with the air-segmented injection principle. The sample plug has been turned into an aerosol by means of a high efficiency nebulizer (HEN) and further introduced into the so-called high temperature torch integrated sample introduction system (hTISIS). A transient signal has been thus obtained. For spiked CSF real samples it has been verified that the higher the temperature, the greater the sensitivity. Under optimized conditions, the hTISIS provides peak areas around four times higher than those provided by the spectrometer default device (i.e., a double pass spray chamber). Additional advantages provided by the former system include limits of detection up to 6 times lower and narrower peaks as compared to those reported for the double pass spray chamber. Furthermore, the use of the hTISIS is not detrimental from the point of view oxide production and doubly charged ion generation. Regarding the extent of non-spectral interference caused by the CSF matrix, it has been verified that, with the hTISIS, recoveries for spiked real samples were close to 100% for a set of 14 different elements (V, Cr, Mn, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Ba, Tl and Pb). Meanwhile, in segmented flow injection mode, the reference system provided recoveries from 200 to 500%, depending on the element and the sample, thus demonstrating the occurrence of matrix effects.

Graphical abstract: Cerebrospinal fluid elemental analysis by using a total sample consumption system operated at high temperature adapted to inductively coupled plasma mass spectrometry

Article information

Article type
Paper
Submitted
12 Jun 2017
Accepted
20 Jul 2017
First published
20 Jul 2017

J. Anal. At. Spectrom., 2017,32, 1916-1924

Cerebrospinal fluid elemental analysis by using a total sample consumption system operated at high temperature adapted to inductively coupled plasma mass spectrometry

Á. Cañabate, E. García-Ruiz, M. Resano and J. Todolí, J. Anal. At. Spectrom., 2017, 32, 1916 DOI: 10.1039/C7JA00210F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements