Issue 2, 2017, Issue in Progress

Transient alternating current electroosmotic flow of a Jeffrey fluid through a polyelectrolyte-grafted nanochannel

Abstract

The purpose of this study is to investigate the flow of viscoelastic fluid through a slit polyelectrolyte-grafted (PE-grafted) nanochannel under applied alternating current (AC) electric field. The PE-grafted nanochannel (also called a soft nanochannel) is represented by a rigid surface coated by a polyelectrolyte layer (PEL) in a brush-like configuration. By solving linearized Poisson–Boltzmann equations and momentum equations, analytical solutions regarding electrical potentials and transient electroosmotic flow (EOF) velocities are derived under appropriate boundary conditions in the decoupled regime of the PE-grafted nanochannel, where the thickness of the PEL is independent of the electrostatic effects triggered by polyelectrolyte charges. We compare the distributions of EOF velocities between PE-grafted and rigid nanochannels. A good agreement with each other is found when the thickness of the PEL is very small. However, the velocity for PE-grafted nanochannels is larger than that for rigid ones. The influences of pertinent dimensionless parameters on the EOF velocities in PE-grafted nanochannels are discussed in detail. The results indicate that the EOF velocity amplitude for PE-grafted nanochannels increases with the thickness of the PEL. Increasing the relaxation time enhances the oscillation of the EOF velocity profiles, yet increasing the retardation time dampens the oscillation. Furthermore, increasing the oscillating Reynolds number Re results in a more obvious oscillating phenomenon of the EOF velocity, together with a weakening amplitude of oscillation. The conclusions have theoretical significance for biofluid-based microfluidic transport systems.

Graphical abstract: Transient alternating current electroosmotic flow of a Jeffrey fluid through a polyelectrolyte-grafted nanochannel

Article information

Article type
Paper
Submitted
09 Oct 2016
Accepted
15 Nov 2016
First published
03 Jan 2017
This article is Open Access
Creative Commons BY-NC license

RSC Adv., 2017,7, 782-790

Transient alternating current electroosmotic flow of a Jeffrey fluid through a polyelectrolyte-grafted nanochannel

F. Li, Y. Jian, Z. Xie, Y. Liu and Q. Liu, RSC Adv., 2017, 7, 782 DOI: 10.1039/C6RA24930B

This article is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported Licence. You can use material from this article in other publications, without requesting further permission from the RSC, provided that the correct acknowledgement is given and it is not used for commercial purposes.

To request permission to reproduce material from this article in a commercial publication, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party commercial publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements