Issue 7, 2018

Compound parabolic collector solar disinfection system for the treatment of harvested rainwater

Abstract

A cost-effective solar disinfection (SODIS) system fitted with a compound parabolic collector (CPC) (SODIS-CPC) was designed for the treatment of rainwater. One system (SODIS-CPC-1) was installed next to a 2000 L rainwater harvesting tank without pre-treatment (Tank 1) and a second system (SODIS-CPC-2) was installed next to a 2000 L tank connected to a pre-filtration first flush (FF) diverter [Tank 2 (FF)]. To analyse the efficiency of the SODIS-CPC systems, roof-harvested rainwater was exposed to direct sunlight in a borosilicate glass reactor for eight hours. Hereafter various physicochemical (e.g. pH, turbidity), chemical (e.g. anions, cations) and microbial (indicator counts using culture-based analysis) parameters were investigated in the untreated and SODIS treated rainwater. The anion and cation concentrations analysed in all the samples were within drinking water guidelines as stipulated by various national and international water associations. The Escherichia coli (E. coli) counts were reduced to below the detection limit in all the samples collected from SODIS-CPC-1 and SODIS-CPC-2 (FF), while the HPC were reduced to within the drinking water guideline of <1.0 × 104 CFU per 100 mL. During the first four sampling sessions, the total coliform counts were reduced to below the detection limit (<1 CFU per 100 mL) after SODIS treatment; however, during the last three sampling sessions, counts with a mean ranging from 1 to 75 CFU per 100 mL were still recorded in the SODIS treated rainwater. For both systems, ethidium monoazide bromide quantitative polymerase chain reaction (EMA-qPCR) analysis revealed a mean reduction of 99.5% in viable Legionella copy numbers when a maximum mean ambient UV-A radiation of 29.5 W m−2 was observed. Similarly, EMA-qPCR analysis revealed a mean reduction of 99.8% in viable Pseudomonas copy numbers when the rainwater temperatures were ≥52 °C in the SODIS treated samples (after eight hours) and a maximum mean ambient UV-A radiation of 20.5 W m−2 was recorded on the sampling day. Thus, while the SODIS-CPC systems improved the quality of harvested rainwater, based on the presence of viable Legionella and Pseudomonas spp. after SODIS treatment, it is recommended that the treated rainwater is utilised for domestic purposes.

Graphical abstract: Compound parabolic collector solar disinfection system for the treatment of harvested rainwater

Supplementary files

Article information

Article type
Paper
Submitted
12 Mar 2018
Accepted
06 May 2018
First published
16 May 2018

Environ. Sci.: Water Res. Technol., 2018,4, 976-991

Compound parabolic collector solar disinfection system for the treatment of harvested rainwater

A. Strauss, B. Reyneke, M. Waso and W. Khan, Environ. Sci.: Water Res. Technol., 2018, 4, 976 DOI: 10.1039/C8EW00152A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements