Issue 16, 2018

A rapid and eco-friendly isothermal amplification microdevice for multiplex detection of foodborne pathogens

Abstract

In this study, a plastic microdevice based on loop-mediated isothermal amplification (LAMP) was fabricated for the amplification and on-chip fluorescence detection of multiple pathogens. Papers infused with LAMP reagents and specific primers were embedded inside the multiple reaction chambers of the microdevice. A solution containing the target pathogens was injected into the sample chamber, located in the center of the microdevice, and evenly distributed to the reaction chambers simultaneously via centrifugal force. For detection, fisetin, a plant-derived fluorophore, was used as the DNA-intercalating dye. Purified DNAs of Escherichia coli O157:H7 (E. coli O157:H7), Salmonella spp., Staphylococcus aureus (S. aureus), and Cochlodinium polykrikoides were successfully amplified and directly detected on the microdevice, where as low as 0.13 and 0.12 ng μL−1 of the DNA of E. coli O157:H7 and S. aureus, respectively, were identified. In addition, the potential of this microdevice for point-of-care testing was further examined by incorporating on-chip sample purification module and testing using a real sample – milk spiked with Salmonella spp. The thermally lysed milk sample was filtered using polydopamine-coated paper embedded inside a sample chamber and seamlessly transported into the reaction chambers by centrifugal force for subsequent LAMP followed by direct on-chip detection inside the reaction chambers in which fisetin-soaked papers were embedded. The limit of detection for Salmonella spp. was determined to be approximately 1.7 × 102 CFU mL−1 using the microdevice. This microdevice is safe, easy to use, selective, and sensitive enough for point-of-care testing to identify foodborne pathogens as well as environmentally harmful microorganisms.

Graphical abstract: A rapid and eco-friendly isothermal amplification microdevice for multiplex detection of foodborne pathogens

Supplementary files

Article information

Article type
Paper
Submitted
23 Apr 2018
Accepted
11 Jun 2018
First published
11 Jun 2018

Lab Chip, 2018,18, 2369-2377

A rapid and eco-friendly isothermal amplification microdevice for multiplex detection of foodborne pathogens

T. N. D. Trinh and N. Y. Lee, Lab Chip, 2018, 18, 2369 DOI: 10.1039/C8LC00424B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.