Issue 21, 2019

Robust chemical bonding of PMMA microfluidic devices to porous PETE membranes for reliable cytotoxicity testing of drugs

Abstract

Here, we report a simple yet reliable method for bonding poly(methyl methacrylate) (PMMA) to polyethylene terephthalate (PETE) track-etched membranes using (3-glycidyloxypropyl)trimethoxysilane (GLYMO), which enables reliable cytotoxicity tests in a microfluidic device impermeable to small molecules, such as anti-cancer drugs. The porous PETE membranes treated with 5% GLYMO were assembled with microfluidic channel-engraved PMMA substrates after air plasma treatment for 1 minute, followed by heating at 100 °C for 2 minutes, which permits irreversible and complete bonding to be achieved within 1 h. The bonding strength between the two substrates (1.97 × 107 kg m−2) was robust enough to flow culture medium through the device without leakage even at a gauge pressure of above 135 kPa. For validation of its utility in drugs testing, we successfully demonstrated that human lung adenocarcinoma cells cultured in the PMMA devices show more reliable cytotoxicity results for vincristine in comparison to conventional polydimethylsiloxane (PDMS) devices due to the inherent property of PMMA of it being impervious to small molecules. Given that the current organ-on-a-chip fabrication methods mostly rely on PDMS, this bonding strategy will expand simple fabrication capability using various thermoplastics and porous track-etched membranes, and allow us to create 3D-micro-constructs that more precisely mimic organ-level physiological conditions.

Graphical abstract: Robust chemical bonding of PMMA microfluidic devices to porous PETE membranes for reliable cytotoxicity testing of drugs

Supplementary files

Article information

Article type
Paper
Submitted
10 Apr 2019
Accepted
18 Sep 2019
First published
18 Sep 2019

Lab Chip, 2019,19, 3706-3713

Robust chemical bonding of PMMA microfluidic devices to porous PETE membranes for reliable cytotoxicity testing of drugs

T. Nguyen, S. H. Jung, M. S. Lee, T. Park, S. Ahn and J. H. Kang, Lab Chip, 2019, 19, 3706 DOI: 10.1039/C9LC00338J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.