Issue 6, 2020

Tracking copper, chlorine, and occupancy in a new, multi-story, institutional green building

Abstract

Water quality deterioration in buildings poses risks to human health and infrastructure. As such, this research tracked the concentrations of copper and chlorine in the tap water of a new, multi-story, LEED Platinum building over its first six months of occupancy to gain new insights into the building water quality. The building is typical of a university research building, which contains laboratory, office, and common spaces, and is representative of commercial and institutional (CI) buildings in general. Twice weekly, first and second draw grab samples of domestic cold water were collected from breakroom faucets on each floor of the five-story building. Grab samples were analyzed for dissolved copper (Cu) and free chlorine. Building occupancy was approximated using Wi-Fi access point connections that provided hourly counts of wireless devices on each floor. The access point counts showed occupancy patterns typical of university buildings, such as higher counts on weekdays than on Saturday and Sunday, and higher counts during the workday compared to other times. Overall building occupancy was low during the first 3 months of the study and then increased during the second 3 months. The total building occupancy over the study duration ranked by floor was 1st > 3rd > 2nd > 4th > 5th, which followed move-in schedules for the building. The 1st, 3rd, 4th, and 5th floors showed statistically significant difference from each other except for the relationship between the 2nd and 4th and the 2nd and 5th floors. Maximum copper concentrations were in the range of 1.2–1.7 mg L−1 and occurred during the first three months of the study. Cu concentrations decreased on all floors over the six months and showed a moderately strong negative correlation with occupancy by floor. Although building occupancy was increasing throughout the study, chlorine was almost never detectable in all samples over the six months.

Graphical abstract: Tracking copper, chlorine, and occupancy in a new, multi-story, institutional green building

Supplementary files

Article information

Article type
Paper
Submitted
07 Feb 2020
Accepted
19 Apr 2020
First published
20 Apr 2020

Environ. Sci.: Water Res. Technol., 2020,6, 1672-1680

Tracking copper, chlorine, and occupancy in a new, multi-story, institutional green building

R. Richard, K. A. Hamilton, P. Westerhoff and T. H. Boyer, Environ. Sci.: Water Res. Technol., 2020, 6, 1672 DOI: 10.1039/D0EW00105H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.