Issue 15, 2022

Impact of physical and chemical parameters on square wave anodic stripping voltammetry for trace Pb2+ detection in water

Abstract

Exposure to lead, a toxic heavy metal, in drinking water is a worldwide problem. Lead leaching from lead service lines, the main contamination source, and other plumbing materials is controlled by the plumbosolvency of water. Square wave anodic stripping voltammetry (SWASV) has been greatly explored as a rapid and portable technique for the detection of trace Pb2+ ions in drinking water. However, the impact of water quality parameters (WQP) on the SWASV technique is not well understood. Herein, SWASV was employed to detect 10 μg L−1 Pb2+ and determine trends in the stripping peak changes in simulated water samples while individually varying the pH, conductivity, alkalinity, free chlorine, temperature, and copper levels. The pH and conductivity were controlled using the buffer 3-(N-morpholino)propanesulfonic acid (MOPS), and NaNO3, respectively and kept at pH = 7.0 and conductivity = 500 μS cm−1 when exploring other WQPs. The working electrode, a gold-nanoparticle-modified carbon nanotube fiber cross-section (AuNP-CNTf-CS) electrode provided sufficiently sharp and prominent peaks for 10 μg L−1 Pb2+ detection as well as good reproducibility, with a relative error of 5.9% in simulated water. We found that conductivity, and temperature had a proportional relationship to the peak height, and pH, alkalinity, free chlorine, and copper had an inverse relationship. In addition, increasing the copper concentration caused broadening and shifting of the Pb2+ stripping peak. At extremely low conductivities (<100 μS cm−1), the voltammograms became difficult to interpret owing to the formation of inverted and distorted peaks. These trends were then also observed within a local drinking water sample in order to validate the results.

Graphical abstract: Impact of physical and chemical parameters on square wave anodic stripping voltammetry for trace Pb2+ detection in water

Supplementary files

Article information

Article type
Paper
Submitted
27 Apr 2022
Accepted
21 Jun 2022
First published
30 Jun 2022

Analyst, 2022,147, 3542-3557

Author version available

Impact of physical and chemical parameters on square wave anodic stripping voltammetry for trace Pb2+ detection in water

C. E. Rahm, P. Gupta, V. K. Gupta, A. Huseinov, B. Griesmer and N. T. Alvarez, Analyst, 2022, 147, 3542 DOI: 10.1039/D2AN00724J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements