Electrochemical genosensor based on gold nanostars for the detection of Escherichia coli O157:H7 DNA

Abstract

Escherichia coli O157:H7 (E. coli O157:H7) is an enterohemorrhagic E. coli (EHEC), which has been issued as a major threat to public health worldwide due to fatal contamination of water and food. Thus, its rapid and accurate detection has tremendous importance in environmental monitoring and human health. In this regard, we report a simple and sensitive electrochemical DNA biosensor by targeting Z3276 as a genetic marker in river water. The surface of the designed gold electrode was functionalized with gold nanostars and an aminated specific sensing probe of E. coli O157:H7 to fabricate the genosensor. Cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques were applied for electrochemical characterization and detection. The synthesized gold nanostars were characterized using different characterization techniques. The fabricated DNA-based sensor exhibited a high selective ability for one, two, and three-base mismatched sequences. Regeneration, stability, selectivity, and kinetics of the bioassay were investigated. Under optimal conditions, the fabricated genosensor exhibited a linear response range of 10−5 to 10−17 μM in the standard sample and 7.3 to 1 × 10−17 μM in water samples with a low limit of quantification of 0.01 zM in water samples. The detection strategy based on silver plated gold nanostars and DNA hybridization improved the sensitivity and specificity of the assay for E. coli O157:H7 detection in real water samples without filtration. The detection assay has the advantages of high selectivity, sensitivity, low amounts of reagents, short analysis time, commercialization, and potential application for the determination of other pathogenic bacteria.

Graphical abstract: Electrochemical genosensor based on gold nanostars for the detection of Escherichia coli O157:H7 DNA

Supplementary files

Article information

Article type
Paper
Submitted
12 Jan 2022
Accepted
09 Mar 2022
First published
11 Mar 2022
This article is Open Access
Creative Commons BY license

Anal. Methods, 2022,14, 1562-1570

Electrochemical genosensor based on gold nanostars for the detection of Escherichia coli O157:H7 DNA

N. Razmi, M. Hasanzadeh, M. Willander and O. Nur, Anal. Methods, 2022, 14, 1562 DOI: 10.1039/D2AY00056C

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements