Issue 6, 2022

Dynamic in vivo monitoring of fracture healing process in response to magnesium implant with multimodal imaging: pilot longitudinal study in a rat external fixation model

Abstract

Rodent models are commonly used in pre-clinical research of magnesium (Mg)-based and other types of biomaterials for fracture treatment. Most studies selected unstable fixation methods, and there is a lack of multimodal longitudinal in vivo monitoring of bone healing. The purpose of this study is to develop a rat femoral fracture model stabilized by external fixation with intra-medullary Mg implant, and to investigate the dynamic bone union process with several imaging techniques offering complementing insights into the process. Pure Mg pins were prepared, followed by an in vitro degradation test. Male Sprague-Dawley rats in the experimental group underwent femoral osteotomy stabilized by external fixators with intra-medullary implantation of Mg pins, and the control group underwent external fixation without intra-medullary implants. Post-operative radiograph, micro-CT and B-mode ultrasonography were acquired directly after surgery, and re-examined at week 4, 8 and 12. Bone tissue volume, in vivo implant degradation, histological staining and MRI images were analyzed using ex vivo samples. Both groups achieved fracture union at week 12, and the dynamic healing process was illustrated by in vivo radiograph, micro-CT and ultrasonography. Bilateral whole femur ex vivo analysis further demonstrated increased ratio of bone tissue volume in the surgical femur with Mg implants, and in vivo degradation of Mg pins was slower than in vitro results. Titanium screws rather than intra-medullary Mg pins were the source of artifact in MRI. This pilot study showed the rat fracture model with external fixation and intra-medullary Mg implantation to be an effective method for dynamic in vivo monitoring of the bone healing process. Future application of the animal model may facilitate pre-clinical translational research of biodegradable orthopaedic implant materials for fracture treatment.

Graphical abstract: Dynamic in vivo monitoring of fracture healing process in response to magnesium implant with multimodal imaging: pilot longitudinal study in a rat external fixation model

Supplementary files

Article information

Article type
Paper
Submitted
11 Jan 2022
Accepted
09 Feb 2022
First published
10 Feb 2022

Biomater. Sci., 2022,10, 1532-1543

Dynamic in vivo monitoring of fracture healing process in response to magnesium implant with multimodal imaging: pilot longitudinal study in a rat external fixation model

Y. Sun, H. Helmholz, O. Will, T. Damm, B. Wiese, M. Luczak, E. Peschke, B. Luthringer-Feyerabend, T. Ebel, J. Hövener, C. Glüer and R. Willumeit-Römer, Biomater. Sci., 2022, 10, 1532 DOI: 10.1039/D2BM00051B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements