Purification of Mg from extremely low-Mg felsic rocks for isotopic ratio determination by MC-ICP-MS

Abstract

Magnesium isotopes are powerful tracers in various geological processes. The high precision determination of Mg isotopes has however been hampered by difficulties in purifying Mg from extremely low-Mg rocks due to their high matrix/Mg ratios. Here, we present an improved and easily operated column procedure to separate Mg from extremely low-Mg (MgO down to 0.05 wt%) felsic rocks. The purification was carried out in three-step chromatographic procedure using a single column filled with AG50W-X8 resin. Matrix elements with high equilibrium distribution coefficient, such as Fe, Al, and Ca, were eluted with 1.5 M HNO3 quantitatively after step I. Then, K, Na, Ti, Al, Ca and Mn were efficiently removed in 1 M HNO3 by duplicate column procedures (step II and step III). Given that the high cation-resin ratio q for extremely low-Mg samples can drift the Mg peak to an earlier elution, a wide Mg cut is set for step II to avoid Mg loss. The total yield of Mg through the three-step procedure is >99.5% for the extremely low-Mg samples. Magnesium isotopic compositions of synthetic standards and well-studied geological reference materials (GSP-2, GSR-1, RGM-2, GBW07113) were measured using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The long-term reproducibility is ±0.06‰, and the δ26Mg values are consistent with theoretical and previously reported values within errors. Notably, we observed negative Mg isotopic deviation when the amount of Mg purified was ≤5 μg, thus ≥10 μg Mg mass is recommended for loading on the columns. The δ26Mg values of the extremely low-Mg rock standards JR-1 (−0.22 ± 0.03‰, 2SD, N = 9) and JR-3 (−0.08 ± 0.05‰, 2SD, N = 10) are reported for the first time, which can be used to calibrate the inter-laboratory bias in future studies on extremely low-Mg igneous rocks.

Graphical abstract: Purification of Mg from extremely low-Mg felsic rocks for isotopic ratio determination by MC-ICP-MS

Supplementary files

Article information

Article type
Technical Note
Submitted
18 Oct 2021
Accepted
25 Jan 2022
First published
26 Jan 2022

J. Anal. At. Spectrom., 2022,37, 497-507

Purification of Mg from extremely low-Mg felsic rocks for isotopic ratio determination by MC-ICP-MS

Y. Wang, Y. Zhang, X. Li, S. Ke, A. Sun, R. Yang, W. Yang and Y. He, J. Anal. At. Spectrom., 2022, 37, 497 DOI: 10.1039/D1JA00359C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements