A digital microfluidic platform coupled with colorimetric loop-mediated isothermal amplification for on-site visual diagnosis of multiple diseases

Abstract

Traditional diagnosis of infectious diseases relies on advanced analyzers in central hospitals, which is not sufficient for rapid control of epidemics, especially in resource-limited areas, raising the importance of the development of diagnostic systems for point-of-care testing (POCT). Here, we developed a simple and cost-effective digital microfluidic (DMF) platform in combination with colorimetric loop-mediated isothermal amplification (LAMP) for simple on-site diagnosis of diseases by the naked eye. The DMF chip contained four parallel units for the simultaneous detection of multiple genes and samples at a time. After amplification, the results were visualized by endpoint detection with concentrated dry neutral red on the chip. The whole process could be completed within 45 min and the on-chip LAMP reaction was shortened to 20 min. The analytical performance of this platform was evaluated by the detection of Enterocytozoon hepatopenaei, infectious hypodermal and hematopoietic necrosis virus, and white spot syndrome virus genes of shrimp. The DMF-LAMP assay showed a detection limit of 101 copies per μl for each target, exhibiting comparable sensitivity to the conventional LAMP assay but was more efficient. The sensitivity was also competitive with that of microfluidic-based LAMP assays using other POCT devices such as centrifugal discs regarding the detection of the same targets. Moreover, the proposed device possessed a simple chip structure and high flexibility to integrate multiplex analysis, which was beneficial for further widespread use in POCT. The practicability of the DMF-LAMP assay was verified by the testing of field shrimp. The result of the DMF-LAMP assay indicated a good agreement with the qPCR method, with Cohen's kappa values ranging from 0.91 to 1.00 depending on different targets. For the first time, an image processing method was established based on RGB analysis under different lighting conditions, and a universally adaptable positive threshold was determined regardless of lighting conditions. Paired with a smartphone, the objective analytical method was facile to implement in the field. Moreover, the DMF-LAMP system is easy to extend for a broad range of bioassays, with the advantages of low-cost, rapid detection, ease of use, good sensitivity, and easy readout.

Graphical abstract: A digital microfluidic platform coupled with colorimetric loop-mediated isothermal amplification for on-site visual diagnosis of multiple diseases

Supplementary files

Article information

Article type
Paper
Submitted
19 Dec 2022
Accepted
05 May 2023
First published
06 May 2023

Lab Chip, 2023,23, 2778-2788

A digital microfluidic platform coupled with colorimetric loop-mediated isothermal amplification for on-site visual diagnosis of multiple diseases

M. Xie, T. Chen, Z. Cai, B. Lei and C. Dong, Lab Chip, 2023, 23, 2778 DOI: 10.1039/D2LC01156E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements