An LC-MS/MS method for the quantification of 3-bromotyrosine in plasma from patients diagnosed with eosinophilic esophagitis

Abstract

Eosinophilic esophagitis (EoE) is a disease marked by a surplus of eosinophils, a type of white blood cell that causes inflammation and irritation. The current diagnostic and monitoring procedure for EoE is endoscopy with biopsy, which is invasive, expensive, and leads to tissue tearing in patients. A biomarker in plasma would offer a much less invasive form of disease monitoring for patients with EoE. Eosinophils have been shown to make eosinophil peroxidase, an enzyme that produces hypobromous acid, reacts with primary amines, and forms bromoamides. One product of this biochemical reaction is 3-bromotyrosine. We have optimized a selective, sensitive, and reproducible method to detect and quantify L-tyrosine and 3-bromotyrosine in human plasma using high-pressure liquid chromatography and tandem mass spectrometry (HPLC-MS/MS). Our sample preparation and analysis method requires fewer steps and provides a faster analysis than previous methods. Method validation yielded limits of quantification of 50 ng mL−1 for L-tyrosine and 10 ng mL−1 for 3-bromotyrosine. Calibration curves for quantification were linear from 50 to 500 ng mL−1 with an R2 value of 0.9995 for L-tyrosine and 10 to 300 ng mL−1 with an R2 value of 0.9998 for 3-bromotyrosine. Method variability was assessed resulting in relative standard deviations of 0.98–4.6% for 3-bromotyrosine (n = 18) and 0.20–0.58% for L-tyrosine (n = 18). Method applicability was tested with patients with a confirmed diagnosis of EoE, initially suggesting little to no correlation between eosinophil count and 3-bromotyrosine concentration in plasma. However, we do observe a relationship between eosinophil count and esophageal deformities. More research must be conducted to determine a more definitive correlation.

Graphical abstract: An LC-MS/MS method for the quantification of 3-bromotyrosine in plasma from patients diagnosed with eosinophilic esophagitis

Supplementary files

Article information

Article type
Paper
Submitted
16 Apr 2024
Accepted
04 Sep 2024
First published
04 Sep 2024

Anal. Methods, 2024,16, 6509-6516

An LC-MS/MS method for the quantification of 3-bromotyrosine in plasma from patients diagnosed with eosinophilic esophagitis

M. E. Thomas, J. E. Markowitz, A. C. Arwood, J. M. Germany and W. M. Gilliland, Anal. Methods, 2024, 16, 6509 DOI: 10.1039/D4AY00697F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements