Issue 47, 2024

Real-time optical detection of mercury contamination in drinking water using an amphiphilic recognition probe at liquid crystal/aqueous interfaces

Abstract

Mercury contamination is a global environmental issue due to its toxicity and persistence in ecosystems. It poses a particular risk in aquatic systems, where it bioaccumulates and biomagnifies, leading to serious health impacts on humans. Therefore, effective detection technologies for mercuric ions in natural water resources are highly desirable. However, most existing detection methods are time-consuming, require complicated sample pre-treatment, and rely on expensive equipment, which hinders their widespread use in real-time detection. Here, we present a convenient, rapid, portable, user-friendly, and cost-effective sensing system for detecting Hg2+ ion contamination in water. This system utilizes a highly selective, amphiphilic, and structurally simple molecular probe, N-dodecylamine-di-thiocarbamate (DDC). DDC molecules align at the interface between the liquid crystal (LC) and water, inducing a homeotropic LC orientation. In water samples contaminated with Hg2+, a bright optical texture is observed, indicating the alignment of the 5CB LC in a planar manner at the LC/aqueous boundary. The minimum detectable concentration (LOD) for Hg2+ ions is 5.0 μM in distilled water, with a broad detection range from 5.0 μM to 2 mM. The sensor selectively detects Hg2+ ions over other common interfering metal ions, including Pb2+, Co2+, Ni2+, Cu2+, Cd2+, Zn2+, Cr2+, Mg2+, Na+, K+, and Ca2+. Boolean logic gates, bar graphs, and truth tables are employed to explain the selectivity of this liquid crystal-based sensor. This work demonstrates the significant potential of the sensor for monitoring mercuric ions in natural water resources, offering a promising strategy for controlling mercury pollution.

Graphical abstract: Real-time optical detection of mercury contamination in drinking water using an amphiphilic recognition probe at liquid crystal/aqueous interfaces

Supplementary files

Article information

Article type
Paper
Submitted
08 Aug 2024
Accepted
09 Oct 2024
First published
11 Oct 2024

Anal. Methods, 2024,16, 8139-8147

Real-time optical detection of mercury contamination in drinking water using an amphiphilic recognition probe at liquid crystal/aqueous interfaces

S. Pandey, M. Rashid, V. Singh, G. Singh, C. B. Patel, R. Verma, D. Dev, R. K. Singh and S. K. Singh, Anal. Methods, 2024, 16, 8139 DOI: 10.1039/D4AY01482K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements