Rapid and accurate determination of chlorine isotopic ratios with ICP-MS/MS using O2 reaction gas

Abstract

Chlorine isotopic ratio measurements are useful for stable isotope tracing, isotopic abundance measurements in nuclear chemistry, and accurate determination of concentrations using isotope dilution methods. Accurate and precise determination of Cl isotopic ratios using inductively coupled plasma mass spectrometry (ICP-MS) methods is challenging due to major polyatomic interferences of 16O18O1H+ and 36Ar1H+ on 35Cl+ and 37Cl+, respectively. Previous work has demonstrated that using tandem mass spectrometry (ICP-MS/MS) with either H2 or O2 gas in the collision/reaction cell can significantly improve the precision, but not necessarily the accuracy, of chlorine isotopic measurements over single-quadrupole techniques. In this work, we further investigate ICP-MS/MS, using O2 as a reaction gas, as a technique for accurate determination of Cl isotopic ratios. Using the methodology developed herein we measure both natural and enriched chlorine isotopic ratios in diverse samples matrices, targeting 37Cl isotope enrichment efforts, without the need for complex front-end chemistry (i.e., ion exchange chromatography), while maintaining a typical accuracy and precision better than ∼1%. The reduced need for time-consuming sample processing afforded by this method results in higher sample throughput (>80 measurements/day) relative to other analytical techniques (e.g., thermal ionization mass spectrometry, accelerator mass spectrometry, etc.). This work demonstrates that ICP-MS/MS with O2 as a reaction gas can be a useful tool for making rapid and accurate chlorine isotopic ratio measurements.

Graphical abstract: Rapid and accurate determination of chlorine isotopic ratios with ICP-MS/MS using O2 reaction gas

Supplementary files

Article information

Article type
Paper
Submitted
23 May 2024
Accepted
09 Sep 2024
First published
13 Sep 2024
This article is Open Access
Creative Commons BY license

J. Anal. At. Spectrom., 2024,39, 2502-2507

Rapid and accurate determination of chlorine isotopic ratios with ICP-MS/MS using O2 reaction gas

T. D. Schlieder, N. D. Rocco, M. L. di Vacri, I. J. Arnquist, D. Bottenus, Z. Huber and B. McNamara, J. Anal. At. Spectrom., 2024, 39, 2502 DOI: 10.1039/D4JA00191E

This article is licensed under a Creative Commons Attribution 3.0 Unported Licence. You can use material from this article in other publications without requesting further permissions from the RSC, provided that the correct acknowledgement is given.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements