Issue 11, 2024

A simplified instrumental protocol for trace Nd and Hf isotope measurements (<10 ng) using a MC-ICP-MS and an Apex Omega de-solvating system

Abstract

We reported a simple technique allowing accurate and precise Nd and Hf isotope measurements of samples with low contents using a Neptune Plus MC-ICP-MS and an Apex Omega membrane de-solvating system. By employing a highly sensitive jet sample cone and X skimmer cone, our protocol achieved a low oxide level (<0.05%) at high ion transmission (∼880 V ppm−1 for Nd and 850 V ppm−1 for Hf) and was found to have little effect on the mass fractionation of Nd and Hf. This was accomplished by simple adjustments of the sweep gas of the membrane de-solvating system and the sample gas of the nebulizer. Instrumental sensitivities were enhanced by a factor exceeding tenfold, in comparison to those of standard measurements with wet plasma. Long term measurements of 1 ng Nd solution standards yielded 143Nd/144Nd ratios of 0.512117 ± 0.000032 (2SD, n = 24) and 0.512227 ± 0.000036 (2SD, n = 42) for Jndi-1 and JMC-Nd solutions, respectively, while analysis of 1 ng JMC475 Hf gave 176Hf/177Hf ratios of 0.282163 ± 0.000027 (2SD, n = 21). These results are in agreements with their reference values. Potential interfering elements Ce and Sm are found to have an insignificant influence on 143Nd/144Nd ratios. Lu and Yb have a remarkable effect on 176Hf/177Hf ratios. Improved correction performance can be achieved by using Lu and Yb ratios obtained by analyzing pure Lu and Yb solutions. Five chemically purified rock reference materials are measured with the presented method and the results are consistent with their recommended values. Relative to other approaches, this protocol is rapid and accurate and can be widely applied in Nd and Hf isotope analysis of samples with trace amounts of Nd and Hf (<10 ng).

Graphical abstract: A simplified instrumental protocol for trace Nd and Hf isotope measurements (<10 ng) using a MC-ICP-MS and an Apex Omega de-solvating system

Supplementary files

Article information

Article type
Technical Note
Submitted
31 Jul 2024
Accepted
17 Sep 2024
First published
18 Sep 2024

J. Anal. At. Spectrom., 2024,39, 2694-2702

A simplified instrumental protocol for trace Nd and Hf isotope measurements (<10 ng) using a MC-ICP-MS and an Apex Omega de-solvating system

T. Zhou, L. Qi, S. Liu and B. Zhou, J. Anal. At. Spectrom., 2024, 39, 2694 DOI: 10.1039/D4JA00276H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.