Controllable Pump-Free Electrokinetic-Driven Microdevice for Single-Cell Electrorotation
Abstract
Single-cell electrorotation (ROT) has emerged as a fundamental technique for characterizing cellular electrical properties, yet conventional methodologies face significant limitations including laborious cell loading procedures, time-consuming measurements, low throughput, and confined effective operational regions. To address these challenges, we present an innovative pump-free single-cell electrorotation device that synergistically integrates electroosmotic flow (EOF) with ROT technologies. Our design employs time-division multiplexed electrical signal modulation to achieve real-time regulation of EOF velocity and directionality, effectively resolving cell positioning challenges while eliminating the need for complex pumping system. This approach not only reduces experimental cost but also significantly simplifies operational complexity. Furthermore, the implementation of thick-electrode architecture successfully mitigates electric field spatial attenuation, thereby expanding the effective ROT zone and enhancing measurement stability and precision. Comprehensive numerical simulations and experimental validations demonstrate the capability of microdevice for accurate determination of cellular parameters, (eg. membrane permittivity εmem and cytoplasmic conductivity σcyto). We envision that the pump-free single-cell ROT microdevice will provide a new platform for convenient and high-throughput cell electrical characterization.