: a selection tool for asymmetric reflections of spherically bent crystal analyzers for high resolution X-ray spectroscopy

Abstract

High resolution, hard X-ray spectroscopy at synchrotron X-ray light sources commonly uses spherically bent crystal analyzers (SBCAs) formed by shaping a single crystal wafer to a spherical backing. These Rowland circle optics are almost always used in ‘symmetric’ (or nearly symmetric) configurations wherein the reciprocal lattice vector used for energy selectivity via diffraction is coincident with the normal vector to the curved wafer surface. However, Gironda, et al., J. Anal. At. Spectrom., 2024, 39, 1375–1387 recently proposed that asymmetric operation of SBCAs, wherein the reciprocal lattice vector is no longer normal to the wafer surface, has significant operational benefits and has been an underutilized opportunity. First, those authors find improved energy resolution through decreased Johann error, or equivalently find increased solid angle at a chosen experimental tolerance for energy broadening. Second, they find productive, high-resolution use of a large number of reciprocal lattice vectors from a single SBCA, thus enabling operation over a wide energy range without need to exchange SBCA upon making large changes in desired photon energy. These observations hold the potential to improve performance, increase flexibility and decrease cost for both laboratory and synchrotron applications. Given these motivations, we report an open-source software package, Image ID:d4ja00340c-u3.gif, that enables exploration of the complex space of analyzer wafer choice, experimental energy range or ranges, and desired suppression of Johann error. This package can guide both the design and the day-to-day operations of Rowland spectrometers enabled for asymmetric use.

Graphical abstract: : a selection tool for asymmetric reflections of spherically bent crystal analyzers for high resolution X-ray spectroscopy

Article information

Article type
Paper
Submitted
16 Sep 2024
Accepted
09 Dec 2024
First published
28 Jan 2025

J. Anal. At. Spectrom., 2025, Advance Article

Image ID:d4ja00340c-u1.gif: a selection tool for asymmetric reflections of spherically bent crystal analyzers for high resolution X-ray spectroscopy

J. E. Abramson, Y. Chen and G. T. Seidler, J. Anal. At. Spectrom., 2025, Advance Article , DOI: 10.1039/D4JA00340C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements