No significant crystal orientation effect during sulfur isotope analysis of marcasite using SIMS

Abstract

The sulfur isotopic composition of marcasite (FeS2, orthorhombic), a dimorph of pyrite (FeS2, isometric), can be used to trace ore-forming fluid source(s) and ocean acidification events in deep time. However, matrix-matched standards for marcasite are scarce, and in practice, a pyrite standard is commonly used to calibrate the sulfur isotope ratio of marcasite during laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) and secondary ion mass spectrometry (SIMS) analyses. Recently, it has been suggested that it is feasible to calibrate the sulfur isotope ratio of marcasite with a pyrite standard during SIMS analysis, but the crystal orientation effect during sulfur isotope analysis of marcasite using SIMS remains unexplored. We investigated this topic by analyzing a natural marcasite sample (NJUMc-1). We analyzed NJUMc-1 using LA-MC-ICP-MS and SIMS. The analysis spots for LA-MC-ICP-MS and SIMS were very close to each other, and both spots were located in domains with the same brightness in backscattered electron images (BSE). The results derived from these two methods lie around a 1 : 1 line in a δ34SLA-MC-ICP-MS vs. δ34SSIMS binary diagram, indicating that SIMS data are comparable to LA-MC-ICP-MS data. However, there are some grains in which δ34SLA-MC-ICP-MS deviates from δ34SSIMS (“δ34SLA-MC-ICP-MS_NJUδ34SSIMS” >+2‰ or <−2‰). This discrepancy possibly indicates a crystal orientation effect during SIMS analysis. To confirm whether there is a crystal orientation effect during SIMS analysis, we conducted a second round of LA-MC-ICP-MS analysis in Beijing and selected two sets of NJUMc-1 marcasite grains and conducted electron backscatter diffraction (EBSD) analysis. For the first set of NJUMc-1 grains, characterized by variable “δ34SLA-MC-ICP-MS_Beijingδ34SSIMS” values, there is no correlation between crystal orientation and “δ34SLA-MC-ICP-MS_beijingδ34SSIMS” values. For the second set of NJUMc-1 grains, characterized by “δ34SLA-MC-ICP-MS_Beijingδ34SSIMS” values around 0‰, highly variable crystal orientations are observed. These findings suggest that if a crystal orientation effect exists during SIMS analysis, it should be no larger than 1.5‰.

Graphical abstract: No significant crystal orientation effect during sulfur isotope analysis of marcasite using SIMS

Supplementary files

Article information

Article type
Paper
Submitted
12 Oct 2024
Accepted
24 Jan 2025
First published
04 Feb 2025

J. Anal. At. Spectrom., 2025, Advance Article

No significant crystal orientation effect during sulfur isotope analysis of marcasite using SIMS

R. Li, J. Yan, J. Yu, X. Wang, T. Yang, S. Qian, C. Wang and H. Xian, J. Anal. At. Spectrom., 2025, Advance Article , DOI: 10.1039/D4JA00367E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements