MPI Performance of Magnetic Nanoparticles Depends on Matrix Composition and Temperature: Implications for in Vivo MPI Signal Amplitude and Spatial Resolution

Abstract

One of the hallmark advantages of magnetic particle imaging (MPI) is the linear relationship between MPI signal and the concentration of magnetic nanoparticles (MNPs), allowing absolute tracer quantification. However, intrinsic tissue matrix parameters may affect the MPI signal, often unknown a priori, presenting a challenge for accurate in vivo MNP quantification in living subjects when using standard calibration curves obtained from simple aqueous MNP suspensions. We investigated the effects of matrix composition and temperature on the MPI signal amplitude and full width at half maximum (FWHM, metric for spatial resolution) for three different MNPs in gelatin and bovine serum albumin (BSA) phantoms and five different ex vivo tissues. Decreasing matrix compressibility (increasing viscosity) led to decreased MPI signal amplitude and increased FWHM. For 8% w/v gelatin (compressibility=3.5×10-10 m2/N, viscosity=363.4×103 mPa·s), the MPI signal amplitude of MNPs was ~50% of that in aqueous solutions (compressibility=8.4×10-10 m2/N, viscosity=1 mPa·s), while the FWHM increased by an average of 115%. For 5% w/v BSA samples (compressibility=1.2×10-10 m2/N, viscosity=198.6×103 mPa·s), a 44% MPI signal reduction and 98 and 90 % increase of FWHM was observed for gold-iron oxide nanoflowers and ferucarbotran, respectively, compared to water (0% w/v). MNPs injected in ex vivo tissues also showed lower MPI signal amplitudes compared to aqueous solutions. Temperature also played a small role in MPI quantification, with the MPI signal amplitude of ferucarbotran decreasing by nearly 10% from 55 to 10 ℃. The current results suggest that accurate in vivo MNP quantification will require reference/calibration samples with matching tissue matrix composition and temperature.

Supplementary files

Article information

Article type
Paper
Submitted
24 juin 2024
Accepted
03 janv. 2025
First published
15 janv. 2025
This article is Open Access
Creative Commons BY-NC license

Nanoscale Adv., 2025, Accepted Manuscript

MPI Performance of Magnetic Nanoparticles Depends on Matrix Composition and Temperature: Implications for in Vivo MPI Signal Amplitude and Spatial Resolution

M. Salimi, W. Wang, S. Roux, G. Laurent, R. Bazzi, P. Goodwill, G. Liu and J. W. M. Bulte, Nanoscale Adv., 2025, Accepted Manuscript , DOI: 10.1039/D4NA00518J

This article is licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported Licence. You can use material from this article in other publications, without requesting further permission from the RSC, provided that the correct acknowledgement is given and it is not used for commercial purposes.

To request permission to reproduce material from this article in a commercial publication, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party commercial publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements