Wen-Long
Huang
a,
Xu-Dong
Wang
a,
Yu-Fei
Ao
ab,
Qi-Qiang
Wang
ab and
De-Xian
Wang
*ab
aBeijing National Laboratory for Molecular Sciences, CAS Key Laboratory of Molecular Recognition and Function, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China. E-mail: dxwang@iccas.ac.cn
bUniversity of Chinese Academy of Sciences, Beijing 100049, China
First published on 17th November 2023
An arm modification strategy, by replacing relatively rigid, electron-deficient side arms with flexible ether chain arms and linking them onto a tetraoxacalix[2]arene[2]triazine skeleton, was utilized to design an artificial molecular hourglass. The planar bilayer experiments confirmed the unimolecular channel mechanism and suggested reversed ion selectivity from the previously reported anion selectivity to weak cation selectivity.
Two structural principles, i.e., macrocyclic skeleton (self-assembled or single macrocycle) and non-covalent driving forces (binding sites), are usually the key concerns for designing synthetic chloride channel molecules. Despite the importance in fundamental science and biology, it is extremely difficult to construct artificial channels that show high Cl−/K+ selectivity as the natural channel protein does because of the large size and high hydration energy of chloride in comparison with potassium.8 In previous work, we have designed the molecular hourglass 1 using (1) tetraoxacalix[2]arene[2]triazine as the central and narrow part, (2) electron-deficient aromatic imides tethered by glycol chains on both sides of the macrocycle as the extending arms, and (3) phenylalanine moieties as the terminal heads (Fig. 1a).9a The advantages of the functional central macrocycle and anion–π driving force endowed moderate Cl−/K+ selectivity (PCl−/PK+ = 1.90). Furthermore, a “mutation” strategy through replacing the inert benzene rings with active phenol rings enabled a cooperative anion–π and hydrogen bonding interaction mode at the central macrocycle.9b Such structural change provided a second molecular hourglass with high Cl− selectivity (PCl−/PK+ up to 12.31). Besides, owing to the sensitivity of terminal phenylalanine moieties to the environment, the second molecular hourglass showed pH-dependent transport behaviours. As a key constructive component of the molecular hourglass, we wondered how the electron-deficient arms would affect the chloride transport selectivity. To probe the contribution of the hourglass arms, we herein designed a new molecular hourglass 2 through an arm modification strategy on the initial molecular hourglass 1 (Fig. 1b). Specifically, electron-rich 1,3-dialkoxybenzene moieties are applied instead of electron-deficient aromatic imides as the main component of the arms. The synthesis, ion transport activity, and ion selectivity of molecular hourglass 2 are presented.
Fig. 1 The structures and electrostatic potentials of artificial molecular hourglass 1 (a) and 2 (b). Blue and red bars represent electron-deficient and electron-rich regions, respectively. |
The artificial molecular hourglass 2 was synthesized smoothly through monomer preparation, one-pot macrocyclization, and subsequent derivatizations (Scheme 1, also see ESI,† Section S2). Starting with commercially available raw materials of resorcinol and two alkyl bromides, primary amine fragment 5 was firstly prepared with modest yield. The pivotal resorcinol monomer 6 was obtained by condensation reaction between 5 and 3,5-dihydroxybenzoic acid. One-pot macrocyclization between resorcinol monomer 6 and cyanuric chloride produced tetraoxacalix[2]arene[2]triazine macrocycle 7 in 30% yield. Nucleophilic substitution reaction between 7 and primary amine fragment 5 provided the precursor compound 8 in 79% yield. The benzyl groups of 8 were removed under H2 gas with Pd/C to afford the target molecular hourglass 2 in 32% yield.
The anion and cation association ability of artificial molecular hourglass 2 was initially assessed through 1H NMR titration experiments. Upon the gradual addition of Bu4N+Cl− to the solution of 2 in d6-acetone, proton H14 within the macrocycle cavity shifted upfield, and then downfield, and protons H12 and H13 moved downfield continuously (Fig. 2c and Fig. S1, ESI†), which suggested anion–π binding between Cl− and the triazine rings.9a,10 The continuous downfield motion of amide proton H11 and amino proton H11’ indicated hydrogen bonding interactions between Cl− and these two kinds of protons. The peak shape variation of protons H5 and H5′, and partial downfield movement of aryl protons (H4, H6, H7, etc.) and alkyl protons (H1, H10, etc.) manifested the non-covalent interactions between arm components with Cl−. Compared with Cl−, with the continuous addition of K+PF6−, these protons showed relatively smaller chemical shift changes (Δδ < 0.08 ppm, Fig. 2b and Fig. S2, ESI†). However, these changes still disclosed non-covalent contact of K+ to the components of the molecular hourglass. The titration experiments indicated that 2 possessed the ability to bind Cl− and K+, but showed stronger affinity toward Cl− (association constant: K1 = 1067.0 ± 28.8 M−1, K2 = 23.1 ± 0.2 M−1, with a 1:2 host–guest stoichiometry) than K+ (K1 = 242.9 ± 35.2 M−1, K2 = 4.2 ± 0.1 M−1) (Table S1, ESI†).
The bilayer lipid membrane inserting ability and channel-forming potential of artificial molecular hourglass 2 were primarily evaluated by a vesicle fluorescent assay.9,11 For this assay, a halogen-sensitive fluorescent dye, lucigenin, was utilized as an indicator, which was encapsulated into vesicles prepared with egg yolk phosphatidylcholine (EYPC). The EYPC vesicles containing NaNO3 buffer solution (pH = 7.0) inside were suspended into M+Cl− buffer solution (M = Li, Na, K, Rb, or Cs, pH = 7.0) to establish a M+Cl− concentration gradient across the lipid membrane (Fig. S3, ESI†). The M+Cl− flow across the vesicle membrane mediated by molecular hourglass 2 was checked by monitoring the fluorescence intensity variation of lucigenin. With the addition of molecular hourglass 2, the fluorescence intensity decreased gradually with time (Fig. S4, ESI†), which indicated that 2 possessed the ability to embed into the lipid membrane to transport ions across the membrane. However, when the concentration of 2 increased to about 25 μM (ratio of 2 to lipid = 18.5 mol%) in the vesicle fluorescent assay, a precipitation phenomenon was observed, which was possibly caused by the poor solubility of 2 in buffer solutions. Due to this unexpected situation, the attempt to obtain the half-maximal effective concentration (EC50) from fitting of the dose–response curve with the Hill equation failed.
The incorporating capability of artificial molecular hourglass 2 into planar lipid membrane was further investigated through a planar bilayer lipid membrane conductance measurement experiment (BLM). In the BLM tests, 1,2-diphytanoyl-sn-glycero-3-phosphocholine (DPhPC) was applied to form a planar lipid membrane around a small pore (diameter: ca. 200 μm) on a recording cup.12 The lipid membrane separated the chamber and cup into cis and trans sides, which were filled with KCl bath solution (1.0 M, 1.0 mL) with an Ag/AgCl electrode immersed into each side. After adding channel molecules into the cis chamber side and applying voltage across the planar membrane, channel current signals can be recorded with time. With the addition of molecular hourglass 2 (1.0 μL THF solution, final concentration: 1.0 μM) to the cis side and stirring for a few minutes, a voltage in the range of −150 mV to +150 mV was applied successively. In current traces, representative and reproducible square-top channel current signals were observed (Fig. 3a, b and Fig. S6, ESI†), which corresponded to the conversion of the “open” and “closed” state of the ion channel, and definitely confirmed that artificial molecular hourglass 2 spanned the lipid bilayer and transported ions through the channel mechanism. The current–voltage plot is shown in Fig. 3c, which presents a linear current–voltage relationship, giving a slope conductance value of 18.9 ± 0.7 pS by linear fit.
Fig. 3 Current traces of 2 at (a) 150 mV and (b) 120 mV in symmetrical KCl bath solutions (cis/trans = 1.0 M/1.0 M). I–V plots under (c) symmetrical (cis/trans = 1.0 M/1.0 M) and (d) asymmetric (cis/trans = 1.0 M/0.25 M) KCl bath solutions. Reversal potential Vr = −9.37 mV.9a,13 The final concentration of 2 is 1.0 μM. |
The ion selectivity of artificial molecular hourglass 2 was also studied with a BLM test in asymmetric KCl bath solutions (cis/trans = 1.0 M/0.25 M). The reversal potential (Vr) was obtained to be −9.37 mV from linear fit of the current–voltage relationship under KCl concentration gradient conditions (Fig. 3d). Using this reversal potential, the Cl−/K+ permeability ratio PCl−/PK+ was determined to be 0.54 with the Goldman–Hodgkin–Katz equation. This value was relatively smaller than previously reported ones for anion-selective molecular hourglass channels (PCl−/PK+ = 1.909a and 4.179b, respectively). The permeability ratio unambiguously indicated that opposite to its analogues, artificial molecular hourglass 2 was a cation-selective channel and slightly preferred K+ transport over Cl−. The comparatively weak K+ ion selectivity14 may be attributed to the following aspects: (1) the electron-rich arms of 2 could not efficiently compensate the dehydration sacrifice of Cl− as the electron-deficient arms of 1 did, which largely obstructs the transmembrane transport of Cl−, but facilitates that of K+ (hydration energy of Cl− and K+: 381 vs. 322 kJ mol−1); (2) K+ is smaller than Cl− in size (radius: 1.38 vs. 1.81 Å),15 so it could pass through the narrow central skeleton more easily. To further verify our presumptions, we investigated the ion selectivity using ion pairs in terms of different hydration ion radii and hydration energies.15,16 The results showed Cl−/Mg2+ (PCl−/PMg2+ = 0.62), K+/Cs+ (PK+/PCs+ = 1.29), Cl−/Br− (PCl−/PBr− = 136.59) and K+ > Mg2+ selectivity. These results highlight the effects of both ion size and hydration energy (Fig. S8, ESI†). Thus, the smaller size and lower hydration energy of K+, combined with the effective compensation of dehydration sacrifice by the channel molecule may contribute to the weak cation selectivity of 2.
In conclusion, utilizing a side arm modification strategy to tether relatively flexible and electron-rich phenyl alkyl ether chain side arms to a tetraoxacalix[2]arene[2]triazine macrocyclic model scaffold, a neoteric artificial molecular hourglass was designed and synthesized. This molecular hourglass can effectively embed into an artificial lipid bilayer membrane and participate in transmembrane ion transport through a unimolecular channel mechanism. Possibly due to a balance effect involving ion size, hydration energy, and the efficient compensation of ion dehydration sacrifice, a weak cation selectivity was resulted in contrast to its previously reported analogues with electron-deficient arms. These observations revealed that, by restructuring the side arms of an artificial molecular hourglass, the ion transport selectivity can be conveniently and purposefully regulated. Thus, these artificial molecular hourglass channels may find applications in modulating ion homeostasis. Moreover, the transport activity of the elegantly designed molecular hourglass in living cells is highly attractive, which is an ongoing interest in our laboratory.
This work was supported by the National Natural Science Foundation of China (22171271, 22022112), Beijing National Laboratory for Molecular Sciences (BNLMSCXXM-202002), and BMS junior fellow scholarship.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d3cc04573k |
This journal is © The Royal Society of Chemistry 2023 |