Helen
Chadwick
Department of Chemistry, Faculty of Science and Engineering, Swansea University, Swansea, SA2 8PP, UK. E-mail: h.j.chadwick@swansea.ac.uk
First published on 11th June 2024
A recently developed magnetic molecular interferometry technique allows the experimental determination of how the amplitudes and phases of the molecular wave-function change during the collision of a gas phase molecule with a surface. This information, quantified by a scattering-matrix, provides a very stringent benchmark for developing accurate theoretical models as they can also be determined from scattering calculations and are particularly sensitive to the underlying interaction potential. However, the value of this comparison is necessarily limited by the accuracy with which an empirical scattering-matrix can be extracted from the experimental data. This paper presents the methods used to analyse the measurements and uses simulations to determine how various uncertainties in modelling the different magnetic elements which make up the beamline of the apparatus affect the accuracy with which the scattering-matrix can be extracted. It is shown that when signals have a noise level which corresponds to on the order of 1% of the oscillation amplitude, the uncertainties in the modelling do not significantly affect the ability to extract the scattering-matrix elements, with the error in the extracted values increasing to a few percent as the noise in the signals is increased to 10% of the oscillation amplitude. This therefore gives an estimate of the accuracy of the parameters that can be obtained from future measurements.
Using these measurements has led to great strides being made in the development of accurate theoretical models of some aspects of H2 scattering from surfaces, for example, in the case of the dissociation of H2 on Cu(111),16 Cu(100),17 Cu(110),18 Pt(111),19 Pt(211),19 Ru(0001),20 Ni(111)21 and NiAl(110)22 surfaces, the initial sticking coefficients determined experimentally can be reproduced theoretically within an accuracy of 4.2 kJ mol−1, often referred to as within chemical accuracy.16–21 There have also been numerous studies of diffractive scattering of H2 from surfaces4,5,23,24 which have provided stringent tests of theory, some of which have been met and some of which have yet to be reproduced as accurately by the calculations. For example, the PES which describes the dissociation of H2 on Ru(0001) with chemical accuracy fails to reproduce the diffraction intensity for elastically scattered H2 molecules.20 For H2 scattering from NiAl(110), the PES which accurately reproduces the dissociation probabilities22 also correctly predicts rotationally elastic diffraction intensities,25 but fails to reproduce the rotationally inelastic diffraction intensities with the same level of accuracy.26
Whilst the scattering studies mentioned above have provided useful benchmarks for comparing and developing accurate theoretical models, the experimental observables are only sensitive to certain aspects of the scattering-matrix (S-matrix), which is what theoretical models can calculate.27 These calculated S-matrices characterise how the amplitude and phase of the wave-function of the molecules before collision change due to scattering from the surface and are extremely sensitive to the underlying PES. The use of the magnetic molecular interferometer (MMI) technique allows extraction of both the relative amplitudes and phases of (rotational orientation projection) mJ state to mJ state resolved S-matrix elements from the experimental data, as has been demonstrated previously for the elastic scattering of H2 from LiF28 and Cu(511)29 surfaces, providing results which are directly comparable to those obtained from calculations. However, the value of these benchmarks is limited by how accurately the S-matrix can be extracted from the experimental data, which in turn is limited by how well the MMI apparatus has been characterised. This paper will present the analytical methods used to extract empirical scattering-matrices from the MMI measurements, and how any uncertainties in these methods influence the parameters that are obtained from the fits. Firstly, how signals are simulated for an MMI experiment will be discussed and how this allows scattering-matrix parameters to be extracted from the data, before addressing how uncertainties in the transmission probabilities of the different states that make up the molecular beam through two magnetic hexapole lenses in the machine affect the ability to extract the S-matrix parameters from the data. In this section, the influence that the signal to noise ratio of the signal which is being fit has on the accuracy of the S-matrix elements that are obtained from the data analysis will also be considered. Then, the methods used for obtaining the magnetic field profile through the beamline is presented and the influence that any errors in this have on the ability to analyse the data is discussed, before presenting a summary and the main conclusions of the work.
A nozzle is used to generate the molecular beam expansion, where it is assumed that all nine mI, mJ states of hydrogen in I = 1, J = 1 are equally populated. This will also contain molecules in I = 0, J = 0 which cannot be manipulated in the apparatus, and which give a constant background in the measurements. The central part of the expansion passes through a skimmer to create a molecular beam which then continues through the rest of the beamline of the apparatus. There are two hexapoles36,37 in the beamline, which create inhomogeneous magnetic fields where the different mI, mJ states experience either a restoring or deflecting force depending on whether their magnetic moment is greater than or less than 0, and two solenoids, which create tuneable uniform magnetic fields which allow the coherent control of the mI, mJ states as characterised by the Hamiltonian given by Ramsey.35 At the end of the first arm of the machine, there is a UHV chamber where the surface is mounted, and at the end of the beamline, there is a highly sensitive custom built detector38 which operates on the same principle as a mass spectrometer, ionising the molecules, mass filtering them and detecting the resulting current.
In previous studies28,30,32,34 the probabilities that the different mI, mJ states are transmitted through the second hexapole were approximated as being independent of the probability that they are transmitted through the first, which gave 18 hexapole probabilities, one each for the transmission of the nine initial mI, mJ states through the first hexapole, and another nine for the transmission of each of these states through the second hexapole. However, the probability that an mI, mJ state will be transmitted through the second hexapole will depend both on its magnetic moment and its trajectory through the machine, which is influenced by the first hexapole.39 For example, a molecule which is initially in the mI = 0, mJ = 0 state will not be deflected by the first hexapole and therefore follow a slightly divergent path, but one in the mI = −1, mJ = −1 state will be focussed to follow a parallel path through the machine. If both molecules reach the entrance of the second hexapole in the mI = −1, mJ = −1 state, then the probability of the second hexapole transmitting them will be different despite them being in the same final mI, mJ state. To account for this, the semi-classical trajectory code used previously to calculate the hexapole probabilities40 for both arms of the machine independently has been modified to allow the trajectories to undergo either specular or diffractive scattering at the surface and continue down the second arm of the machine to calculate probabilities for all 81 initial state, final state combinations. It was found that these 81 values could not be reproduced using the initial approach of modelling the two arms independently, and therefore this more sophisticated method of calculating the hexapole probabilities is required. The hexapole probability for a state being transmitted through both hexapoles for an initial mI, mJ state |n〉 in the first hexapole and final mI, mJ state |f〉 in the second hexapole will be denoted as Phex(f ← n), where the quantisation axes for these states are defined by a dipole element directed along Z immediately after the end of the first hexapole and −Z′ before the start of the second.
At the end of the first hexapole, the states in the molecular beam are still described as pure mI, mJ states but with different populations, as any superposition states decohere in the strong magnetic field gradients of the hexapole.41 For this reason, the starting point of the coherent wave-function propagation of the molecules through the measured magnetic field profile of the machine are the pure mI, mJ states defined with respect to the Z axis (see Fig. 1). Each pure mI, mJ state is propagated through the magnetic field profile of the first arm of the machine up to the surface using the Ramsey Hamiltonian35 using the methods described in ref. 30. Repeating this calculation for each of the nine pure mI, mJ states produces the coherent super-position states that the initial states evolve into, which is denoted as U(B1). The calculation is performed in the same way for propagating the molecules through the second arm of the machine, although the quantisation axis is taken to be the Z′ direction (see Fig. 1). The resulting coherent super-position states obtained from propagating the nine pure mI, mJ states through the second arm are denoted as U(B2).
After passing through the first hexapole and first solenoid, the molecules scatter from the surface, where it is assumed that the mI state is a spectator to the collision as the surfaces considered here are non-magnetic, and the interaction time too short for spin–rotation or spin–spin couplings to significantly alter the state of the molecule. The scattering process can change both the amplitude and phase of the (mJ state) wave-functions, which is characterised by the scattering-matrix (S). Multiplying the wave-function before scattering by the scattering-matrix gives the wave-function after scattering. For the case of the elastic scattering of H2 in I = 1, J = 1, S is a 3 × 3 matrix of complex numbers where each element is related to the scattering of an initial mJ state (n′) to a final mJ state (f′), where the quantisation axis is taken to be the surface normal. Note that the quantisation axis chosen for calculating the scattering-matrix is arbitrary in the sense that it will not affect the outcome of the scattering event and therefore the surface normal was chosen to follow previous conventions.42 In principle, this matrix contains 18 parameters in total, as it contains 9 amplitudes () and 9 phases () as given in eqn (1).
(1) |
(2) |
Combining the above, it is possible to write the coherent-superposition state (|Ψn〉) resulting from the propagation of an initial pure mI, mJ state |n〉 from the end of the first hexapole to the start of the second as
|Ψn〉 = U(B2)R(θ2)SR(θ1)U(B1)|n〉 | (3) |
(4) |
(5) |
A second uncertainty is due to the nozzle position with respect to the entrance of the first hexapole. Whilst before experimental measurements the nozzle position is optimised to maximise the pressure of the molecular beam going into the UHV chamber, this does not exclude the possibility that the nozzle is slightly misaligned. Hexapole probabilities were therefore also calculated using a 250 μm expansion source with a 100 μm misalignment (bottom left) and with a 200 μm misalignment (bottom right), with the results shown as the contour plots in the bottom row of Fig. 2. The 200 μm shift has a larger effect on the probabilities, with the most significant differences again being seen for μf > 0.
To determine the effect that the uncertainty in the hexapole probabilities has on being able to fit experimental data, signals were simulated for scanning B1 at B2 values of 0 gauss metre and 11.2 gauss metre using an identity scattering-matrix and three randomly generated scattering-matrices (within the constraints given in eqn (2)) and the fitted hexapole probabilities corresponding to a 50 μm expansion and to a 250 μm source with a 200 μm shift. These signals were then analysed in the same way as used to analyse previous experimental data,28,31i.e., allowing the S-matrix parameters and a background parameter to vary. The fits were run 100 times with initially randomised parameters using the Nelder and Mead downhill simplex algorithm49 with simulated annealing to minimise the difference between the input signals and fits, and the results that produced the minimum error are presented in Fig. 3, where the top row corresponds to simulated signals generated using the identity scattering-matrix and the bottom row the first randomly generated scattering-matrix, and the left and right columns correspond to signals which were simulated with 50 μm expansion probabilities and signals simulated with 250 μm expansion shifted by 200 μm probabilities respectively. In each panel, the black line shows the initial simulated signal that was fit to, the red dashed line the fit to the data that was obtained using the hexapole probabilities that were used to produce the simulated data and the blue dotted line the fit to the data obtained by using the other set of hexapole probabilities. As can be seen, it is not possible to fit the simulated signals with the incorrect hexapole probabilities and the sensitivity to the probability values used varies for different scattering-matrices. As a result, this uncertainty needs to be incorporated into the method used to analyse the experimental data.
Whilst all 81 hexapole probabilities could be allowed to vary in the signal analysis, at least in principle, it is unlikely that the fits will converge on a single set of parameters. Furthermore, many of these probabilities are very low and have a negligible effect on the signal. It is therefore desirable to try and find a reduced parameter model which describes these probabilities, the parameters for which could then be freed when analysing the experimental data. The model that was used was a double Gaussian distribution, given by
Phex(f ← n) = Aexp(−σ1(μn − μ1)2 − (Cμn + σ2)(μf − μ2)2) | (6) |
μy = −amI − bmJ | (7) |
Fig. 4 Hexapole probabilities calculated using the trajectory calculations described in the text (left column), the fit to the probabilities obtained using the parameters in Table 1 in eqn (6) (middle column), and a comparison of the simulated signals obtained using the calculated (black solid line) and fit (red dashed line) hexapole probabilities. The calculations were performed for a 50 μm expansion (top row), 250 μm expansion without a shift (second row), 500 μm expansion (third row), 250 μm expansion with a 100 μm shift (fourth row) and 250 μm expansion 200 μm shift (bottom row). |
Set of probabilities | Parameter | ||||
---|---|---|---|---|---|
σ 1 | μ 1 | C | σ 2 | μ 2 | |
50 μm | 0.0967 | −6.5482 | 0.1763 | 0.5966 | −2.1123 |
250 μm no shift | 0.0967 | −6.5482 | 0.1367 | 0.5966 | −2.2900 |
500 μm | 0.0967 | −6.5482 | 0.0604 | 0.5966 | −2.1770 |
250 μm 100 μm shift | 0.0967 | −6.5482 | 0.1186 | 0.5966 | −2.2517 |
250 μm 200 μm shift | 0.0967 | −6.5482 | 0.0000 | 0.5966 | −2.2284 |
To determine whether it is possible to account for the uncertainty in the expansion size and nozzle position when analysing the experimental data whilst still being able to reliably extract a scattering-matrix, fits were run on simulated signals generated using the identity scattering-matrix and three randomly generated scattering-matrices using the hexapole probabilities corresponding to a 50 μm expansion and a 250 μm expansion shifted by 200 μm. Before running the fits, a constant background was added to each signal to mimic the polarisation losses that occur through the beamline as well as random noise sampled from a Gaussian distribution with a standard deviation defined as a percentage of the oscillation amplitude (maximum–minimum). When fitting the data the scattering-matrix elements, a constant to account for the background and the values of C and μ2 in eqn (6) were allowed to vary, with the latter two parameters limited to the range that cover the values in Table 1. The relative scattering-matrix amplitudes and phases obtained from the analysis of the signal generated using the identity scattering-matrix (top row), first random scattering-matrix (second row), second random scattering-matrix (third row) and third random scattering-matrix (bottom row) are shown in Fig. 5 and 6 respectively, where each panel corresponds to the S-matrix element given in the label, and only the unique values from eqn (2) are presented. The results corresponding to the signal generated using the 50 μm expansion hexapole probabilities are shown as black crosses, the 250 μm expansion shifted by 200 μm hexapole probabilities as red circles, and the dashed lines the values of the (relative) scattering-matrix parameter which was used to simulate the signal. In each panel the results from the best 10 fits to each set of data are presented, as it has previously been demonstrated29 that considering only a small number of fits with the lowest fitting error is a valid way of presenting the results and has no effect on the conclusions. At low noise levels, the returned S-matrix elements correspond to those that were used to calculate the data for signals simulated with both sets of hexapole probabilities, demonstrating that the uncertainty in the hexapole probabilities can be accounted for when fitting the data and does not affect the ability to extract the scattering-matrix elements. As expected, the values of the S-matrix elements obtained from the fits deviate more significantly from the value used to simulate the data as the noise level increases. The results that are presented also suggest that if the noise level is on the order of 1%, the values of the scattering-matrix parameters that are obtained from the fit are likely to be accurate. In some cases, most notably the middle three panels in the top row of Fig. 6 and the third and fourth panels in the third row of Fig. 6, the errors in the phases are larger, going beyond the ±0.314 limits of the axes (i.e., ±5% of the maximum range of values). In all cases, these phases correspond to values of S-matrix amplitudes which are zero (in the case of the identity scattering-matrix in the top row) or small values of S-matrix amplitudes (in the case of the second random scattering-matrix in the third row; see the equivalent panels in Fig. 5) meaning these elements do not significantly contribute to the signal. Consequently, there is a larger uncertainty in the value of these phases, even at lower noise levels. Whilst the extracted S-matrix parameters do become less accurate as the noise increases, the deviation between the value input to the simulation and value obtained from the fit tend to lie within ±0.1 in the case of the amplitudes, and ±0.314 in the case of the phases. This means that even for noisier data the errors on the returned scattering-matrix parameters are likely to be on this order, although it is important to note that if the S-matrix amplitudes are small, this will likely lead to larger errors in the associated phases as discussed above.
It is also worth noting that if the experimental data is too noisy to reliably extract an S-matrix, it could still be used to benchmark theoretical models as a signal could be simulated using the S-matrix obtained from the calculation and compared to the experimental data, mirroring an approach used previously when studying rotationally inelastic scattering31 where it was not possible to do the two different measurements28 that are required to extract a unique scattering-matrix. If the measured and simulated signals disagree the result would suggest the model is not correct, and if the two agree it would lend support that the model could be correct, although it is unlikely to provide definitive proof of the accuracy as many signals could agree with the measurement within the error bars of the data.
To conclude this section, a comparison of the results obtained by fitting data using the method described above in which the transmission probabilities of the molecules through the second hexapole depends on their mI, mJ state in the first hexapole (which will be described in the following as the new model), and the method of having independent hexapole probabilities characterising the transmission probabilities through the first and second arm of the machine used in previous studies28,32 (referred to as the old model) is presented. Recently published data taken for the specular scattering of H2 from Cu(511) at different surface temperatures29 will be used as an example, where the analysis in that work was performed using the new model. Fig. 7 presents the fits obtained to the measurement (black line) using the new model (red dashed line) and the old model (blue dotted line) for a B1 scan at B2 = 0 gauss metre (top row) and a B1 scan at B2 = 11.2 gauss metre (second row) for a surface temperature of 200 K, with the equivalent data measured at a surface temperature of 550 K being shown in the third and fourth rows. The left column presents all the data, whereas the right column shows a magnification of the central oscillation. The fits to the data in both cases are very good, but as can be seen the fit to the data using the new model tends to be slightly better than that of using the old model. In ref. 29 it was concluded that the rotational selectivity and rotational polarisation (see eqn (7) and (8) in ref. 29 for the definition of these quantities) decreased as the surface temperature increased. Table 2 presents the values of these parameters at the two surface temperatures obtained from the fits to the measured data using the two different hexapole probability models. As can be seen, the trends in the rotational selectivity and rotational polarisation are the same regardless of which model is used to describe the hexapole probabilities when analysing the data, i.e., both decrease as the surface temperature is increased, meaning had the old model been used it would not have affected the conclusions of that work.
Model | Surface temperature = 200 K | Surface temperature = 550 K | ||
---|---|---|---|---|
Selectivity | Polarisation | Selectivity | Polarisation | |
Old model | 0.48 | 0.62 | 0.29 | 0.43 |
New model29 | 0.49 | 0.56 | 0.35 | 0.39 |
The measurement of the magnetic field profile39 was done using two different commercially available probes, with an AlphaLab Vector Gauss Meter being used for the majority of the beamline, but a LakeShore Instruments model 410 probe where the magnetic fields are greater than 200 gauss. These have limited accuracy which will be particularly problematic when measuring the non-ideal fields present in the profile, with the AlphaLab Vector Gauss Meter having a stated accuracy of ±0.02 gauss. This error can further be compounded as the probe needs zeroing in a zero-field region just prior to the measurement (before drift effects become significant), which can introduce an additional small offset to the measurement. Whilst the probe can measure the X, Y and Z components of the field simultaneously, there is a small (∼mm) offset between the sensors which means that the field values measured at a particular distance along the beamline are not at the same point in space, which will also introduce a small inaccuracy. Additionally, due to the physical size of the probe it is not possible to measure the field profile across the diameter of the molecular beam path, where it would be reasonable to assume it could vary at different positions. There are also inherent challenges with these measurements which reduces their accuracy, not least that the total beamline that needs characterising is over 3 metres long and in places where the magnitude of the magnetic field changes quickly measurements are required at separations on the order of 1 mm. Inaccessibility of some parts of the beamline also presents a problem, making that region of the profile difficult to measure. Furthermore, it is also difficult to ensure that the probe is in the correct orientation, and therefore there could also be an error of several degrees in the angle, which would be expected to have a particularly marked effect on the measurement of XD1 and XD2 due to the presence of the stronger dipole field.
Whilst the measured magnetic fields throughout the apparatus provide a valuable starting point for the profile, due to the difficulties mentioned above they are not expected necessarily to be sufficiently accurate to use in the analysis of MMI measurements. A good method for determining whether this is the case is to compare measurements of 3He scattering from a Cu(111) surface performed at different nozzle temperatures with signals calculated using wave-functions propagated through the measured magnetic field profiles. 3He is used as only the initial mI = 1/2 state and final mI = 1/2 state can be considered to contribute to the signal (any atoms in mI = −1/2 will just reduce the amplitude of the oscillation) which removes any uncertainty due to the hexapole transmission probabilities. Likewise Cu(111) is used as it is non-magnetic, and therefore the mI state is not expected to change due to scattering and the S-matrix is therefore an identity scattering-matrix which also removes that ambiguity. This means that the small differences that are observed between the experimental and the calculated signals can be attributed to inaccuracies in the magnetic field profile. Nevertheless, these small differences can be removed by making small corrections to the non-ideal fields that are present in the measured magnetic field profile. Before describing how this can be achieved, it is first necessary to present the features of the 3He signals that are obtained and how they are sensitive to different aspects of the magnetic field profile.
Examples of experimental signals for 3He scattering from Cu(111) are presented as black lines in Fig. 9, where the signal in each row was measured at the nozzle temperature and fixed field detailed in the middle panel of that row, and each column focusses on a different region of the magnetic field scan showing a different spin-echo, with the first and third column showing either the parallel50 (B1 = B2, largest amplitude) or anti-parallel50 (B1 = −B2, smallest amplitude) echo, and the middle column showing the X′33 echo when B1 is scanned (top two rows) and the X33 echo when B2 is scanned (bottom two rows). Results from simulations, which are described and presented in the ESI,† show that the amplitude and phases of each of these echoes has a different dependence on each of the non-ideal fields that are present in the measured magnetic field profile, which provides a strategy for determining the integral of these fields in the beamline as described below.
As shown in the third rows of Fig. S1 and S2 (ESI†), if the value of R1 − R2 is kept constant, the signal for the parallel echo is the same regardless of the individual values of R1 and R2. This property is used to determine the value of the difference between the residual fields by comparing the oscillations around the parallel echo (B1 = B2) in the B1 (B2) scans that were measured at non-zero values of B2 (B1) with parallel echoes simulated for different values of R1 − R2, to find the value of R1 − R2 that minimises the difference between the calculated and measured signals. Then, the same is done for the anti-parallel echo (B1 = −B2) which is shown to be independent of the individual values of R1 and R2 when the sum of the two is kept constant (fourth row, Fig. S1 and S2, ESI†), which provides the value of R1 + R2. These two results allow the values of R1 and R2 to be found. Finally, the value of XD1 is determined by comparing the amplitude of the simulated and measured X′ echo (fifth row, Fig. S2, ESI†), and XD2 optimised using the same procedure but using the X echo (sixth row, Fig. S1, ESI†). In all optimisations, the value of the field being optimised is changed by changing the integral of the fields shown in the top and bottom panels of Fig. 8 but leaving the length and shape the same as that in the measured profile.
A comparison of the experimental data (black) and signals calculated (red dashed lines) with wave-functions propagated through the optimised magnetic field profiles is shown in Fig. 9, with the two shown to be in excellent agreement in the case of these echoes. As a final check, these optimised profiles are then used to run wave-function propagations to calculate U(Bx) which are then used to simulate signals for the B1 and B2 scans where B2 = 0 gauss metre and B1 = 0 gauss metre respectively to compare with measurements performed under the same conditions. The excellent agreement is also observed in this case, as shown in Fig. S4 of the ESI.† Whilst the optimised magnetic field profiles that are obtained using this method clearly result in calculated signals that reproduce the 3He measurements well, the values of R1 and R2 are reduced by 2 to 3 gauss centimetre, and XD1 and XD2 reduced to approximately 40% of the original measured value.
The simplicity of the spin evolution of 3He results in a sensitivity to the total magnetic field integrals rather than to the exact shape of the magnetic field profile, meaning that while the procedure outlined above allows the integrals of the various non-ideal fields to be determined, it cannot provide unique values for the length and magnitude of the field. However, when the optimised magnetic profiles are used for more complex beams, such as H2, the exact shape of the profile rather than just the field integral might be important. It is therefore important to determine to what degree the precise details of these non-ideal fields need to be known.
To do this, the optimised residual fields R1 and R2 were replaced with different length and different height rectangles, where the parameters were chosen to maintain the same field integral, and XD1 and XD2 were replaced with triangles which correctly reproduced the amplitudes of the X and X′ echoes respectively. The different approximations used for each of the non-ideal fields are compared with those that are in the optimised profile (black lines) in the top row of Fig. 10. These were then used to define alternative magnetic field profiles which combined the measured profiles for the solenoids and dipole fields with the approximate fields for R1 and R2, or XD1 and XD2, or both, with the details of which profile contained which approximation given in Table 3. As shown by the bottom two rows of Fig. 10, which presents the signals simulated for the different echoes for 3He scattering calculated using wave-functions propagated through these different profiles, the signals that are obtained from each profile are indistinguishable.
Non-ideal field | Profile | ||||||
---|---|---|---|---|---|---|---|
1 | 2 | 3 | 4 | 5 | 6 | 7 | |
R 1 | Rec. | Short1 | Short2 | Opt. | Short1 shifted +5 mm | Short1 shifted −5 mm | Short1 |
R 2 | Rec. | Short1 | Short2 | Opt. | Short1 shifted +5 mm | Short1 shifted −5 mm | Short1 |
XD1 | Opt. | Opt. | Opt. | Tri. | Opt. | Opt. | Tri. |
XD2 | Opt. | Opt. | Opt. | Tri. | Opt. | Opt. | Tri. |
To determine whether these different profiles affect the ability to extract a scattering-matrix from the H2 data, fits were run to signals which included 1% noise for the identity and first randomly generated scattering-matrix using the wave-functions propagated through the magnetic field profiles given in Table 3. The results obtained for fitting the signal generated using an identity S-matrix are presented in the first and third rows of Fig. 11, with the top row presenting the scattering-matrix amplitudes, and the third the phases, and the amplitudes and phases obtained from fitting the signal simulated using the first randomly generated scattering-matrix are shown in the second and fourth rows, respectively. The values obtained for the ten fits with the minimum error are shown in each panel for the signal simulated using hexapole probabilities corresponding to a 50 μm expansion (black crosses) and 250 μm expansion shifted by 200 μm (red circles). Whilst fitting the data, the scattering-matrix elements, a background parameter, and the two parameters which can account for the difference in the hexapole probabilities were allowed to vary. Replacing the measured R1 and R2 fields with a rectangle which is the same length as the residual field (profile 1) or approximately half the length (profile 2) does not significantly affect the ability to extract the scattering-matrix values used in the simulations. Shifting this shorter profile by +5 mm (profile 5) or −5 mm (profile 6) also does not have a significant effect on the extraction of the S-matrix elements for the identity matrix (first and third row), although the deviation in the random scattering-matrix amplitudes is larger (second row). Changing the measured XD1 and XD2 fields to triangles (profiles 4 and 7) tends to have a larger effect, making the extracted scattering-matrix elements and those used to simulate the signals deviate more, but as a general rule the S-matrix amplitudes are still within 0.05 of those used in the simulations, and phases within 0.2. The largest deviations are seen in the case of profile 3, where the optimised R1 and R2 have been replaced by a rectangular residual field which is 10 times shorter and 10 times larger (to keep the same field integral). In some of the panels, the results for profile 3 cannot be seen due to the size of the deviations, where the amplitudes obtained from the fit can be up to 0.4 away from the value used to simulate the data, and the maximum difference in the phases being approximately 3, which effectively flips the phase of the oscillation of that component of the fit. Whilst these differences are unquestionably significant and would reduce the ability to extract reliable scattering-matrix elements from MMI measurements, magnetic field profile 3 is unrealistic given the measured magnetic field profiles and the possible uncertainties that are present in them. The remaining profiles are a more realistic representation of the possible uncertainties in the measured magnetic field profiles, although should still be considered to represent extreme cases, for example in profiles 5 and 6 the (rectangular) residual fields have been shifted by ±5 mm, whereas the uncertainties in the positions are more likely to be on the order of ±2 mm. Likewise, the length of R1 and R2 are unlikely to be wrong by a factor of 2 (which corresponds to approximately 10 cm), which is the change that was made between profiles 1 and 2, which the results show does not significantly change the value of the scattering-matrix elements obtained by fitting the simulated signals.
Fig. 11 The (unique) amplitudes (top two rows) and phases (bottom two rows) of the scattering-matrix elements obtained by fitting the signals generated for an identity scattering-matrix (first and third row) and the first randomly generated scattering-matrix (second and fourth row) with 1% noise using the 50 μm expansion hexapole probabilities (black crosses) and the 250 μm shifted by 200 μm expansion (red circles) using the magnetic field profiles noted along the x-axis. The magnetic field profiles used in the propagation correspond to those defined in Table 3. The dashed horizontal lines show the value of the scattering-matrix elements used to simulate the data. |
To summarise this section, it is not sufficient to just rely on the comparison between simulated and measured signals for 3He scattering to obtain the magnetic field profile, as all seven profiles considered here produced the same simulated 3He signals. Instead, it is essential to measure the magnetic field profile as accurately as possible as this provides a starting point for characterising the profiles of the beamline. Once this is obtained, it can be tweaked within the limits of what the uncertainties can realistically be, without affecting the ability to extract the scattering-matrix elements. This demonstrates that this procedure is robust, and the uncertainties in it do not restrict the analysis of the MMI signals to obtain reliable empirical S-matrices.
To calculate the signal accurately requires knowledge of both the probabilities that the nine different mI, mJ states of H2 in I = 1, J = 1 are transmitted through the two hexapoles of the apparatus, and the magnetic field profile of the machine. The 81 hexapole probabilities can be obtained using semi-classical trajectory calculations, and the resulting probabilities can be described by a double Gaussian model. Whilst this is characterised by five parameters (plus an arbitrary normalisation constant), only two need to be allowed to vary to account for the uncertainty in the size and the position of the molecular beam expansion in the MMI apparatus. Freeing these two parameters in fits to simulated data does not hamper the ability to extract a scattering-matrix when there is a good signal to noise ratio, which corresponds to errors on the order of 1% of the maximum oscillation amplitude. Even with a higher signal to noise ratio which may prevent an S-matrix being reliably extracted from the data, the measurement can still be used to benchmark calculations by comparing signals calculated using theoretical results and those measured experimentally. Whilst this is a less good test than being able to compare empirical and calculated S-matrix values directly, the oscillation curves measured experimentally are interference patterns, and therefore the comparison between the measurement and the calculated signal is still sensitive to both the amplitudes and phases of the S-matrix elements.
To determine the magnetic field profile, the X, Y and Z components of the field in the beamline were measured as accurately as possible using commercially available gauss meters.39 Whilst these measurements provide a starting point, 3He measurements are used to adjust the non-ideal fields in the magnetic field profile, i.e., the magnitude of the residual fields in both arms of the machine (R1 and R2) and the X and X′ components of the dipoles (XD1 and XD2), until the simulated signals agree with those determined experimentally at a range of nozzle temperatures. The residual fields are obtained by comparing the parallel50 (B1 = B2) and anti-parallel50 (B1 = −B2) echoes between the measured and calculated profiles, and the X and X′ components of the dipoles determined using the intensity of the X and X′ echoes.33 The profiles are then validated by comparing with data measured where the non-scanned magnetic field was fixed at 0 gauss metre. As has been demonstrated, the same simulated signals for 3He can be produced using wave-functions that have been propagated through several different magnetic field profiles which share the same field integral values. Fitting simulated H2 scattering signals with wave-functions propagated through each of these different profiles shows that the S-matrix elements used to simulate the signals can be obtained when the magnetic field profile is similar to the measured profile, and only adjusted within what could be a reasonable measurement error. Changing the profile more than this can produce the same simulated signals for 3He scattering but results in significant errors in S-matrix elements extracted from H2 scattering experiments, demonstrating that the combination of measuring the magnetic field profile and 3He simulations and experiments are required to obtain a profile that can then be used to analyse H2 MMI measurements, and that using either individually does not produce a magnetic field profile for the beamline with sufficient accuracy. The relative insensitivity of the fitting procedure to the details of the non-ideal fields demonstrates the robustness of the methods used for obtaining empirical scattering-matrices.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4cp01785d |