Swaroop
Chakraborty
*a,
Nathan
Langford
a,
Yvonne
Kohl
b,
Dimitra-Danai
Varsou
c,
William
Stokes
d,
Evangelos
Papaioannou
e,
Sascha
Wien
b,
Kata
Berkesi
e,
Andrew
Britton
d,
Bashiru
Ibrahim
a,
Antreas
Afantitis
f,
Alexandros
Zoikis Karathanasis
e,
Andrew
Nelson
d and
Eugenia
Valsami-Jones
*a
aSchool of Geography, Earth and Environmental Sciences, University of Birmingham, B15 2TT Birmingham, UK. E-mail: s.chakraborty@bham.ac.uk; e.valsamijones@bham.ac.uk
bFraunhofer Institute for Biomedical Engineering IBMT, Joseph-von-Fraunhofer-Weg 1, Sulzbach 66280, Germany
cNovaMechanics MIKE, Piraeus 18545, Greece
dSchool of Chemistry, University of Leeds, Leeds LS2 9JT, UK
eCreative Nano, Metamorfosi, Athens, 14451, Greece
fNovaMechanics Ltd, Nicosia 1070, Cyprus
First published on 12th November 2024
Considering the increasing interest in utilising nanoparticles (NPs) for advanced, safe, and sustainable coatings, this paper addresses the toxicological concerns associated with nickel–silicon carbide (Ni–SiC) electroplated nanocomposite coatings as an alternative to conventional chromium electrodeposition. We present Ni–SiC nanocomposite coatings as potential substitutes and conduct a comprehensive investigation into the impact of impregnated SiC particles on coating properties. Specifically, we examined the aging of Ni-Watts type and Ni Watts–SiC nanocomposite coatings in various environmental and biological media. Our release and transformation data indicate an enhanced release and transformation of Ni in the simulated media (e.g., up to 200 μg mL−1 in cell culture media) and the formation of NiO and Ni(OH)2 species as confirmed by XPS analysis. Transmission electron microscopy data reveal the release of SiC NPs in the respective simulated aging medium. The Ni ion release from Ni-Watts type and Ni–SiC nanocomposite coatings was also investigated in silico to support safe-by-design (SbD) approaches in the development of nanoalloys for electroplating. An in vitro cytotoxicity assay according to ISO shows a significant reduction in cell viability for Ni–SiC nanocomposite coated samples (up to 80% after 72 hours) compared to standalone Ni-Watts type electroplated coatings (up to 20% after 72 hours). Our findings suggest that the co-deposition of Ni with SiC NPs enhances Ni release, which is a major factor in causing toxicity. These results could be pivotal in the adoption of safe and sustainable by design principles within the electroplating industry. This paper contributes to the fields of nanotoxicology and surface coatings, providing a foundation for designing and optimising environmentally friendly, high-performance coatings with broad industrial applications.
Environmental significanceThe environmental significance of this study lies in its critical evaluation of nickel–silicon carbide (Ni–SiC) nanocomposite electroplating as an alternative to traditional chromium electroplating, with a focus on its environmental and biological impacts. While Ni–SiC coatings offer superior mechanical properties, their enhanced Ni ion release in various media, particularly in biological environments, poses significant environmental and health risks. The release of Ni ions and SiC nanoparticles into ecosystems can lead to detrimental effects in living organisms, raising concerns about their long-term environmental persistence and toxicity. This research highlights the importance of adopting safe-by-design (SbD) principles to develop coatings that balance performance with environmental safety. By highlighting the potential ecological hazards of Ni–SiC nanocomposite coatings, the study advocates the development of safer, more sustainable alternatives, contributing to the broader goal of reducing the environmental footprint of the electroplating industry. |
Surface properties of materials are of crucial importance for industrial and commercial applications. It has been proven that surface properties can be improved by means of nanocomposite coatings.4 In particular, Ni matrix nanocomposite coatings are very promising candidate materials as an alternative to HC coatings due to their potential to achieve excellent wear and corrosion resistance and high hardness, reaching 1100 HV.5 Nanocomposite coatings, particularly those based on Ni matrices, are emerging as promising replacements for HC coatings due to their ability to achieve similar or superior hardness, wear resistance, and durability. The potential of nanocomposites lies in their tailored structure;6,7 for instance, lightweight composites made from linear low-density polyethylene (LLDPE) with embedded tungsten (W) particles have shown enhanced radiation shielding properties while maintaining material strength and reduced weight.8 This example illustrates how the inclusion of nanomaterials, like tungsten nanoparticles, can create multifunctional composites that address specific industrial challenges. Similarly, the superparamagnetic behaviour observed in Ta2O5 nanopillars with Ni tips indicates that tailored nanostructures can exhibit distinct magnetic characteristics, which might open additional applications for Ni–SiC coatings in areas like magnetic storage, biomedical imaging, or electronic devices. By evaluating the magnetic response of Ni–SiC coatings, especially under varied thermal conditions, this study could help position these materials as multifunctional, potentially expanding their industrial relevance beyond corrosion and wear resistance.6,7,9–11
Simultaneously, among potential alternatives, electrodeposited Ni–SiC nanocomposite coatings have emerged, incorporating ceramic particles for enhanced properties. Addition of hard ceramic NPs, like SiC, into the Ni matrix has demonstrated the ability to boost coating hardness and wear resistance.5 Additionally, Ni–SiC nanocomposite coatings can possess desirable characteristics in their as-plated state, with SiC reinforcement offering benefits without subsequent heat treatment.12 These coatings show immense promise in applications where wear resistance and corrosion protection are vital. However, concerns about the potential release of these composite coatings have underscored the necessity for comprehensive safety evaluation.13
The release of Ni and SiC NPs from coatings into the environment via leachates is concerning, given the status of Ni as a toxic pollutant from anthropogenic sources like mining and industrial waste.14 Similarly, inorganic NPs and their dissolved species have been identified as emerging contaminants with significant implications for both environmental and human health.15,16 To assess the potential risks of chemical release, static immersion testing is commonly used. This method, standardised under ISO 10271-2020, evaluates the fouling of materials and the release of chemical leachates from coatings in various simulated media.17 By characterising the leachates from static immersion cells, our aim was to gain insights into their toxicological potential, informing environmental safety assessments. Assessing cytotoxicity, especially with released Ni and SiC NPs, would be critical to understand the challenges due to their unique properties at the nano level.9 The overarching aim of this study is to understand the role of NP impregnation in the stability and efficacy of Ni electroplating. We used a comprehensive approach by assessing ageing, toxicity, and in silico studies to assess safety by design. Our aim is to understand the stability of standalone Ni-Watts type and Ni–SiC nanocomposite electroplated coatings by performing static immersion testing followed by assessing the transformation and toxicity of leachates. Through a systematic investigation into the influence of SiC particle incorporation on coating characteristics, this research seeks to offer valuable insights for designing and optimising Ni–SiC composite coatings, enabling their widespread application across industries.
In the preparation phase, substrates underwent polishing and cleansing with acetone. These samples were selectively masked to enable targeted electroplating within a specific 3 cm × 3 cm active area. Final processing involved rinsing the samples with deionised water (DI), activating them in a 10% v/v HCl solution, and immersing them as cathodes in the electrolyte bath.
Both experimental sets employed a conventional Watts-type electrolytic bath, differing primarily in the composite bath's addition of SiC NPs and SDS surfactant. The SiC NPs, employed for reinforcement, boasted a nominal size of 100 nm. The chemical composition of the electrolytic baths is detailed in Tables 1 and 2. Throughout the study, a pulse current was applied via a Metrohm Autolab PGSTAT12 potentiostat/galvanostat electrochemical system.
Ni/SiC electrolytic bath composition | |
---|---|
Compound | Concentration (g L−1) |
NiSO4·6H2O | 300 |
NiCl2·6H2O | 35 |
H3BO3 | 40 |
Saccharin | 2 |
SiC NPs | 10 |
Electroplating conditions |
---|
pH = 3.8 |
T = 50 °C |
Pulse current with a 50% duty cycle |
T on = Toff = 0.05 s (f = 10 Hz) |
Current density = 2 A dm−2 |
Watts electrolytic bath composition | |
---|---|
Compound | Concentration (g L−1) |
NiSO4·6H2O | 300 |
NiCl2·6H2O | 35 |
H3BO3 | 40 |
Saccharin | 2 |
Sodium dodecyl sulfate (SDS) | 2.5 |
Electroplating conditions |
---|
pH = 4.4 |
T = 50 °C |
Direct current |
Current density = 2 A dm−2 |
Concerning electroplating operations in the composite electrolytic bath, a preliminary hour-long ultrasonication treatment ensured homogeneous dispersion of SiC NPs within the electrolyte. High-energy ultrasonication at 200 W, 95% amplitude, and a 50% duty cycle, utilising a 7 mm diameter tip, was employed. Subsequently, the electrolyte was stirred at 400 rpm to sustain NP suspension, with pH adjusted to 3.8 using aqueous NH3. A stable temperature of 50 °C prevailed throughout the 5 hour electroplating process, yielding approximately 30 μm coating thickness. Post-electroplating, samples underwent DI water rinsing, demasking, ultrasonication bath cleaning, and drying. Contrarily, within the Watts electrolytic bath, direct current was utilized, maintaining pH at 4.4 and a constant 50 °C temperature during the entire 2 hour process, resulting in approximately 30 μm coating thickness.
The cathodic current efficiency (yield) of the plating process was calculated from the theoretical mass gain of the electrodeposited coating using Faraday's law of electrolysis compared to the actual mass gain of the coatings. The microhardness of the Ni–SiC nanocomposite coatings was determined using a Shimadzu Micro Hardness Tester HMV-G20. The surface morphology and NP distribution in the coating was studied with a TESCAN scanning electron microscope coupled with an energy dispersive X-ray spectrometer (EDS). The scanning electron microscopy (SEM) analysis was conducted using a fixed time mode with a resolution tailored to the specific area of interest. The scan yielded a total count of 1142
751 with a real time of 125.64 seconds and a live time of 114.827 seconds. The recorded dead time accounted for approximately 8% of the total acquisition time. The SEM was operated at a landing energy of 20 keV. These parameters provided detailed insights into the sample morphology and composition, enabling accurate characterization of the material under investigation. The silicon content of the coating was determined by XRF using a NITON XL5 XRF tester by Thermo Scientific or by SEM-EDS.
To investigate the release of SiC NPs from the Ni–SiC nanocomposite coated plates, we performed transmission electron microscopy (80 kV, Jeol 1400, Japan) of the leachates exposed to various media. Further, we also performed X-ray photoelectron spectroscopy (XPS) of the aged Ni-Watts type coated and Ni–SiC nanocomposite electroplated surfaces post-aging to investigate transformation of Ni–SiC nanocomposites upon exposure to various media. Briefly, the media exposed coatings were measured on a SPECS enviroESCA with a Phoibos NAP 150 hemispherical analyser with 1D-DLD detectors and a monochromated 40 W Al K-α (1486.7 eV) X-ray source. The analysed spot size was 0.3 mm in diameter. The plates were secured to the sample holder with conductive carbon tape. Three different spots were measured within the exposed area and one spot measured outside the area for each sample. Surveys were measured at a pass energy of 100 eV and a step size of 1 eV, and high-resolution scans were measured at a pass energy of 50 eV and a step size of 0.1 eV. The findings of these studies were correlated with the leaching and cytotoxicity data to understand the impact of Ni and SiC release from the electroplated surfaces.
With the coated surface (approximately 3 cm × 3 cm) facing upwards, the sterile Ni–SiC nanocomposites and Ni-Watts type electroplated samples were positioned in the aging cells and coated with 2.0 mL of CCM each. Following extract formation at 37 °C, 5% CO2, and 90% relative humidity for 24 and 72 hours, the extracts were consolidated per time point and sample type. The extracts from the aging-cells with Ni–SiC electroplated samples at 24 hours, aging-cells with Ni–SiC samples at 72 hours, aging-cells with Ni samples at 24 hours, and aging-cells with Ni samples at 72 hours were combined in a 15 mL tube. Subsequently, the resulting extract underwent cell viability studies and ICP-MS analyses.
Ni-ion release, chosen as the target variable for modelling, exhibited a wide range of values (2.08–1026.54 μg mL−1). To address this, the Ni-ion release values were log-transformed and used as the dependent variable (endpoint) in the models. This transformation was crucial for enhancing the interpretability and the robustness of the subsequent statistical analyses, allowing for a more precise assessment of the coatings' stability and the potential toxicological implications of their use. To enhance our analysis, we excluded variables that consisted solely of duplicates, as they provided no valuable information. We then consulted experts to further refine and limit the variables to the following set:
• Sample coating preparation type,
• Thickness,
• Exposure media (1 mM NaNO3, SS, CCM),
• Media pH,
• Zeta potential,
• Time of exposure (days),
• Chemical composition changes (XPS).
As a final step before modelling, the variables were normalised to ensure that they contributed equally to the analysis. Gaussian normalisation was applied, resulting in mean values of 0 and a standard deviation of 1.20
According to the OECD24 statistical model, validation is essential for evaluating a model's performance. To measure the model's accuracy, appropriate fitness metrics were used for external validation, to measure how closely the model's predictions match actual values. The statistical criteria used to assess the model performance are presented below.
The mean absolute error (MAE, eqn (1)) and the root mean squared error (RMSE, eqn (2)) were used to assess the accuracy of the models. Using these indices together allows for a comprehensive and thorough validation of prediction accuracy, independent of the distribution level of the training-test endpoint values. Lower MAE and RMSE values indicate more reliable models.
![]() | (1) |
![]() | (2) |
The quality-of-fit between the predicted and experimental values for the training and test sets was measured using the coefficient of determination (R2, eqn (3)). Values closer to 1 indicate better-fitting models.
![]() | (3) |
To assess the reliability of predictions on new data (external validation), the external explained variance8,24 was used (Qext2, eqn (4)). This metric compares the predictions for the test set samples with their actual endpoint values, with Qext2 values closer to 1 indicating models with higher predictive power.
![]() | (4) |
Furthermore, the quality-of-fit and the predictive ability of the models were assessed using the statistical criteria of Golbraikh and Tropsha25,26 (see eqn (SI1)–(SI5), including the Qext2, eqn (4)) on the test set (Table S3†).
Finally, we performed the Y-randomisation test27 to ensure that the models' accuracy was not a coincidental outcome. In this test, the modelling calculations were repeated using the initial matrix of independent variables (descriptors) and shuffled values for the endpoint. In each iteration, a model was developed using the scrambled training set and validated with the original test set. If the statistical metrics (e.g., the MAE) of the produced model were deteriorated, compared to the model built with the actual endpoints, then the original model was considered reliable. If the scrambled data produced higher statistical metrics, an acceptable predictive model could not be produced for both modelling methodologies and the original training set.28–30
In this study, similarity measurements based on the Euclidean distance among all training and test samples were used to define the AD of the final model. The distance of a test sample to its nearest neighbour in the training set was compared to the predefined threshold (thr, eqn (5)). In the case where this distance for the test sample exceeded the AD limit, its prediction was considered unreliable. The assessment of the AD of the proposed model was performed in our KNIME workflow, using the Enalos+ Domain–APD node that executes the above procedure.31 The above procedure can be followed for each query sample, when the model is used to assess the ion release of untested samples.
thr = d + Zσ | (5) |
Based on the SEM images depicted in Fig. 1B, the magnification seen in the images at 50 μm reveals that the samples containing SiC NPs exhibit a rougher surface compared to the samples without SiC, which appear smoother. This is likely attributed to the adhesion of NPs on the surface, promoting the surface irregularities. The silicon content of the Ni–SiC nanocomposite coating electrodeposited from the Ni-Watts/SiC electrolyte was also measured by XRF, which resulted in 1 w/w% Si-content in the Ni–SiC nanocomposite. The deposit was also measured by EDS for silicon content and the results demonstrated in Fig. S1† complemented and aligned with the XRF results. The energy-dispersive X-ray spectroscopy (EDS) analysis revealed the elemental composition of the sample. The electroplated surface contained Ni predominantly, i.e., 97.50% atomic percentage and 98.79% weight percentage. Si was also present in the sample, although in a lower amount, accounting for 2.50% atomic percentage and 1.21% weight percentage (Fig. S1†). These results provide crucial information about the sample's elemental makeup, confirming the high concentration of Ni and the presence of Si as a minor constituent.
In stark contrast, Ni release was significantly higher in the CCM and SS media, especially after just 3 days and 5 days, respectively, for both Ni Watts type and Ni–SiC nanocomposite electroplated coatings. For the Ni Watts electroplated coating, Ni release in CCM and SS was 64.5 ± 5.9 μg mL−1 and 81.3 ± 9.3 μg mL−1, respectively. However, Ni release was even higher in Ni–SiC electroplated coatings in CCM and SS, reaching 148.14 ± 3 μg mL−1 and 108 ± 2 μg mL−1, respectively. Visually, the coatings showed significant changes after aging in these biological media (Fig. 2A and C), indicating material degradation, release, or transformation. To prevent bacterial contamination, the aging duration in CCM was limited to 3 days, though longer exposure would likely result in even greater Ni release. This pattern of enhanced Ni release in CCM aligns with the toxicity findings (Fig. 4B), which reported significant toxicity of Ni–SiC nanocomposite samples to MRC-5 cells compared to standalone Ni Watts type electroplated coatings. Each sample demonstrated Ni release, underscoring the potential toxicological impacts on cellular health.
Fig. 2B and D compare the release profiles of Ni from standalone Ni coatings with and without SiC NPs. The data indicate that coatings with SiC exhibited a higher Ni release rate compared to the Ni Watts type coatings. For instance, Ni release in CCM from the standalone Watts type Ni coating and Ni–SiC nanocomposite coating was 64.5 ± 5.9 μg mL−1 and 148.14 ± 3 μg mL−1, respectively. Similar observations were noted across various media, indicating a higher Ni release from Ni–SiC nanocomposite electroplated coatings. This increased release is likely due to the Ni being loosely bound to the SiC NPs, resulting in both Ni and SiC NPs being released into the respective media. Interestingly, Ni release was also observed in environmental media such as WW and ASW in both Ni Watts type and Ni–SiC nanocomposite coatings. Although the Ni release in these simulated environmental media was relatively lower, it was 14.4 ± 2 μg mL−1 and 19.4 ± 2.2 μg mL−1 in ASW and WW, respectively, for Ni–SiC nanocomposite coatings, and 14.1 ± 1.7 μg mL−1 and 3.4 ± 0.3 μg mL−1 for Ni Watts type coatings (Fig. 2B and D). The increased release of Ni from both types of electroplated surfaces in biological media can be attributed to the presence of oxidising groups and weak acids in SS and CCM, which facilitate metal ion dissolution.12,17 This phenomenon is well-documented in the literature, where acidic environments and biological fluids have been shown to enhance the degradation and release of metal ions from coatings.32 Such interactions highlight the critical role of environmental conditions in the behaviour and stability of electroplated coatings in biological applications.
Additionally, TEM images (Fig. 3A) captured post-aging experiments show the dispersal of SiC NPs in the aging media. The extent of NP release varied across different media, being most pronounced in CCM, followed by WW, and least in ASW. This pattern aligns with the ICP-MS measurements of Si and Ni release across the samples (Fig. 2D), confirming the observed trends in SiC NP and Ni metal release. This observed increase in Ni release from coatings with SiC NPs could be attributed to the high surface-to-volume ratio of the NPs, which may loosely capture Ni ions on their surfaces. These ions are then likely released into the aging medium through a diffusion process. As a result, the presence of SiC NPs facilitates a higher level of Ni release into the media compared to coatings that do not incorporate SiC NPs.
XPS spectra (Fig. 3B and C) were analysed and peaks were fitted using casaXPS software.33 The binding energy was calibrated to the assigned carbon aliphatic peak (C–C) in the C 1s spectra at 284.8 eV. For the C 1s and O 1s spectra, the fitted peaks were constrained to the same FWHM and the line shape for all peaks was kept as GL. The binding energy positions were allowed to float within constraints. The Ni 2p spectra can be more complex to fit due to the presence of satellite features creating multiple peaks for each chemical environment.34 A simplified fit was modelled whereby the asymmetric metal peak LA (1.1, 2.2, 10) was used in combination with a symmetric mixed oxide/hydroxide peak and a mixed satellite peak (both GL (30)). The primary purpose was to distinguish between metallic nickel and non-metallic nickel compounds with the lower binding energy of the primary metal peak at 852.5–853 eV being resolvable from the primary hydroxide/oxide peaks at 855.5–856.5 eV and the mixed satellite peaks found at around 860–862 eV. The O 1s spectra can instead be used to distinguish between nickel oxide and nickel hydroxide states with binding energies of around 529.5–529.8 eV and 531.4–531.8 eV, respectively.35 An organic carbon–oxygen peak sits at around 533 eV and the amount matches to a good approximation with the observed C–O states in the C 1s spectra. In summary, the released Ni underwent transformation into NiO and Ni(OH)2 on the surface of the Ni substrate, as evidenced by XPS analysis. While the specific forms of Ni species in the aging media were not directly assessed, it can be inferred from XPS data that the released Ni likely existed in oxide, hydroxide, and other chemical forms. In contrast, the SiC NPs maintained their chemical integrity and didn't show any transformation in their chemical identity. This stability can be attributed to the high solvation energy and low dissolution tendency of SiC NPs in both biological and environmental media, a phenomenon supported by the existing literature on nanoparticle behaviour in various media.
Conversely, the Ni coating did not result in any significant inhibition of metabolic activity. At both 24 and 72 hours, cellular metabolic activity remained within the range of 92%. Correspondingly, regarding cell proliferation, the observations aligned with the outcomes of the WST-1 assay. The proliferation rate was noted at 59.6 ± 2.2% after 24 hours and sharply decreased to 2.7 ± 0.4% after 72 hours (Fig. 4B). Microscopic examination (Fig. 4C) corroborated these findings, revealing distinct alterations in the cellular morphology subsequent to Ni–SiC nanocomposite coating extract incubation with MRC-5 cells. Cells exhibited rounding, loss of adhesion, and eventual detachment (Fig. 4C). These outcomes collectively underscore the distinct effects of Ni–SiC nanocomposite and Ni Watts type coatings on both metabolic activity and cell proliferation, aligning with ISO 10993 guidelines for cytotoxicity assessment.36–39 The heightened cytotoxic response from the Ni/SiC NP coated extract is in agreement with the Ni and SiC release profile as shown in Fig. 2B and D. There was a clear indication of higher Ni release in the case of Ni/SiC electroplated coatings as compared to that of standalone Ni coatings. By ICP-MS, measurements of the formed extract were performed to identify the specific amount of Ni and Si released during the leachate formation (Table S2†). It is well-established in the literature that Ni ions exhibit significant cytotoxicity, which is likely responsible for the majority of observed cytotoxic responses.40 This toxicity is due to not only the presence of free Ni ions but also their transformed chemical forms, such as NiO and Ni(OH)2, and various Ni–organic complexes that form in CCM. These transformed species can interfere with cellular processes, leading to oxidative stress and DNA damage, as documented in numerous studies. Furthermore, the interaction of Ni ions with proteins and other cellular components can disrupt normal cellular function, exacerbating cytotoxic effects. A comprehensive understanding of these mechanisms is crucial for evaluating the safety of Ni-containing coatings.
Based on this finding, the concentration of the tested raw materials was defined. The objective of this is to investigate if the cytotoxic responses predominantly occur due to released Ni ions or the combinatorial effect of both Ni and SiC NPs. For all three Ni-components (NiCl2, NiSO4 and a NiCl2/NiSO4 1:
1 mixture), after 24 hours exposure a dose-dependent increase in metabolic activity was detected (Fig. 5B). Similarly, the WST-1 cytotoxicity assay was performed on MRC-5 cells after they were exposed to a range of concentrations of SiC NPs (0.0156–100 μg mL−1). Interestingly, both spectrometric and microscopic data suggest that SiC NPs are not cytotoxic to MRC-5 cells even at a very high exposure concentration (Fig. 5C). This observation is in agreement with various research articles demonstrating SiC NPs as non-cytotoxic even at a very high exposure concentration.41–45 No differences between the effect intensities could be verified. To confirm the impact of Ni on the morphological changes of MRC-5 cells, we performed microscopy imaging, which validates the findings of cell cytotoxicity upon exposure to Ni ions (Fig. 5A).
To proceed with the modelling steps, data were first randomly divided into training and test sets using a ratio of 0.70:
0.30, following a stratified sampling approach considering the sample exposure media. The training subset was used each time to adjust the model parameters, whereas the test subset was not involved in model development, and it was used as an external validation set to assess the model's performance on new (previously unseen) data. Next, the z-score (Gaussian) normalisation method was employed to standardise the descriptors in the training set (42 samples), ensuring their equal contribution on the model. The identical normalisation parameters were applied to the descriptors in the test set (18 samples).
Two models were then built and trained on the prepared data using XGBoost46 and k-nearest neighbours (kNN).21 The XGBoost model was trained on a subset of the selected variables (sample coating preparation type, thickness, exposure media, and media pH) using 100 boosting rounds. The kNN model was trained using all the selected variables; three neighbours (k = 3) and the neighbours' inversed distances were used as weighting factors for the prediction. To truly gauge their effectiveness, both models were subjected to the test – external validation. This involved using the test set (unseen data) to evaluate the models' generalisability in real-world scenarios.
The respective accuracy statistics of the external validation are presented in Table 3 for both models. In Fig. 6A and B, the results of the Golbraikh and Tropsha25,26 test are presented for the kNN and XGBoost models, respectively. To strengthen the stakeholders' confidence on the predictions, the two models were combined under a consensus scheme: the predictions of each model are averaged, so that the overall predictive accuracy is improved. In Table 3 and in Fig. 6C, the statistics of external validation and the Golbraikh and Tropsha test results for the consensus model are presented.
Metric | kNN | XGBoost | Consensus |
---|---|---|---|
R 2 | 0.895 | 0.848 | 0.898 |
Q ext 2 | 0.899 | 0.854 | 0.902 |
MAE | 0.243 | 0.297 | 0.242 |
RMSE | 0.316 | 0.379 | 0.311 |
![]() | ||
Fig. 6 (A): Golbraikh and Tropsha test results for the kNN model. (B) Golbraikh and Tropsha test results for the XGBoost model, and (C) Golbraikh and Tropsha test results for the consensus model. |
The consensus model demonstrates an improved predictive accuracy compared to the kNN and XGBoost models and also minimizes the possible biases or limitations that could be inherent in the two individual models.
Finally, the Y-randomization test27 was performed 10 times for the kNN and XGBoost models: the MAE values on the test set were calculated in the range of 0.675–1.103 using the kNN model, and in the range of 0.895–1.383 using the XGBoost model, confirming that the predictions were not a coincidental outcome.
The in silico assessment of the Ni-ion release in different media can greatly support the interpretation of the experimental findings and can contribute to the strategic Safe and Sustaianble by Design (SSbD) of Ni–SiC nanocomposite electroplated coatings. In detail, the modelling results corroborate the experimental results in terms of selected variables that can effectively quantify the trends in Ni-ion release, especially the correlation to the exposure conditions (media type and pH) that influence the Ni-ion release (Ni release is highest in biological media like SS and CCM, where acidity and the presence of organic acids facilitate Ni release). Nonetheless, the models – validated with a test set – proved that the predictions closely align with the experimentally measured release values and can be generalised, providing a basis for assessing Ni-ion release in other scenarios (e.g., longer exposure duration) and media not directly tested. In particular, the definition of the AD of the models allows stakeholders to strengthen their confidence on the predictions, during the models' practical use in the SSbD framework. Experimental data alone would require continuous testing under each new condition, while the models can extrapolate reliably within their applicability domain. The in silico approaches are a valuable cost-effective tool within the SSbD framework and their combination with the experimental assessment could also contribute to the prediction of the potentially harmful effects of Ni–SiC nanocomposite electroplated coatings.
The study also underscores the stability of SiC NPs in various media, maintaining their chemical integrity and displaying minimal dissolution. These behaviours can be attributed to their high solvation energy and low dissolution tendency, which is consistent with the existing literature. However, the increased Ni ion release from Ni–SiC nanocomposite coatings, resulting in oxidative stress and DNA damage, underscores the need for careful consideration of these materials' biological impacts.
To optimise the performance, safety, and sustainability of Ni–SiC nanocomposite coatings, several practical strategies can be applied. First, achieving uniform distribution of SiC nanoparticles within the Ni matrix is essential for maximising hardness, wear resistance, and overall durability. This can be accomplished by adjusting SiC concentrations in the electroplating bath and using ultrasonic dispersion techniques during deposition. Post-deposition treatments, such as top coating or surface polishing, can further enhance coating stability by sealing micro-pores and reducing Ni ion and SiC particle release in aggressive environments, such as synthetic sweat or cell culture media. Leveraging in silico modelling to predict Ni ion release in various media also supports optimising formulations, helping to meet safe by design standards by minimising environmental and health risks. Exploring multifunctional properties, such as magnetic behaviour or radiation shielding, could extend the applications of Ni–SiC coatings, similar to tungsten-based nanocomposites used in radiation shielding while maintaining structural integrity.9 Finally, substituting eco-friendly binders or additives in the electroplating bath supports green chemistry goals and aligns with current regulatory standards for safer industrial materials, ultimately promoting sustainable practices within the electroplating industry.
The outlook for future research includes the development of enhanced coating formulations that mitigate Ni release while preserving or improving mechanical properties. The computational models developed for predicting Ni ion release demonstrate significant potential for supporting SbD approaches in developing these coatings. Future work should also explore alternative nanoparticle materials that can offer similar mechanical benefits without the associated toxicity. Additionally, long-term studies on environmental impacts and more in-depth biological assessments will be critical for understanding and mitigating the risks associated with Ni–SiC nanocomposite coatings. This research lays a foundation for advancing the electroplating industry towards safer and more sustainable practices.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4en00751d |
This journal is © The Royal Society of Chemistry 2025 |