Hong Huanga, Jing-Jing Lva, Dan-Ling Zhoua, Ning Baob, Yue Xua, Ai-Jun Wang*a and Jiu-Ju Feng*a
aCollege of Geography and Environmental Science, College of Chemistry and Life Science, Zhejiang Normal University, Jinhua 321004, China. E-mail: ajwang@zjnu.cn; jjfeng@zjnu.cn; Fax: +86 579 82282269; Tel: +86 579 82282269
bSchool of Public Health, Nantong University, Nantong 226019, China
First published on 10th September 2013
Herein, a simple, green, and low-cost way was developed in the synthesis of fluorescent nitrogen-doped carbon nanoparticles (FNCPs) with nitrogen content of 6.88%, using one-pot hydrothermal treatment of strawberry juice. The as-prepared FNCPs exhibited a maximum emission at 427 nm with a quantum yield of 6.3%, which could be specifically quenched by Hg2+. This phenomenon was used to develop a fluorescent method for facile detection of Hg2+ with a linear range from 10 nM to 50 μM and a detection limit of 3 nM (S/N = 3), and further extended to measure environmental water samples with satisfactory recovery. This study provides a green strategy in the synthesis of FNCPs to detect Hg2+ with good performance.
To date, many methods have been developed in the synthesis of carbon nanoparticles, including arc discharge,18 laser ablation,19 electrochemical,20 chemical oxidation,21,22 thermolysis,23,24 ultrasonic,25 and microwave methods.26,27 Among them, hydrothermal synthesis strategy is considered to be a simple, direct, and efficient way to obtain carbon nanoparticles.28
Currently, more increasing efforts have been particularly focused on the preparation of fluorescent nitrogen-contained carbon nanoparticles (FNCPs) because of their broad applications in electrocatalysis, bioimaging, and sensors. For example, Zhu et al. synthesized bifunctional FNCPs by hydrothermal treatment of soy milk, which were used as electrocatalysts for oxygen reduction.29 Wu and coworkers fabricated FNCPs from Bombyx mori silk for bioimaging.30 Liu's group prepared FNCPs with grass as the carbon source, which were applied for the detection of Cu2+.31
Mercury ion (Hg2+) is a widespread pollutant released through natural and human activities, which can accumulate in the human body through the food chain, leading to brain damage and other chronic diseases.32 In recent years, various fluorescent probes have been prepared for the detection of Hg2+ based on biomaterials,33 carbon nanoparticles,34–36 metal nanoparticles,37–39 and semiconductor quantum dots,40,41 because fluorescence technique is a powerful tool with high sensitivity, high selectivity and real time monitoring. However, the tedious synthesis routes, high temperature, toxic agent, and high cost in the synthesis of these fluorescent probes limit their further applications. Thus, it is of great significance to develop novel fluorescent Hg2+ sensors for practical detection of Hg2+ in environmental samples.
Herein, a facile and green method was developed in the synthesis of water-soluble FNCPs by one-pot hydrothermal treating strawberry juice, which can be applied as an Hg2+ sensor (Scheme 1), even extending to the practical detection of Hg2+ in real water samples.
Scheme 1 Schematic illustration of the preparation process for the FNCPs and their application for Hg2+ detection. |
Fig. 1 (A) UV-Vis absorption spectrum of the as-prepared FNCPs. Inset shows the photographs of the FNCPs in aqueous solutions under visible light (1) and UV light (2). (B) Fluorescence excitation (black line) and emission (red line) spectra of the FNCPs. (C) Emission spectra of the FNCPs at different excitation wavelength from 350 to 440 nm. (D) Fluorescence decay traces of the FNCPs in the absence (black line) and presence (red line) of 50 μM Hg2+ upon excitation at 344 nm. The luminescence decay was fitted to a single-exponential decay. |
Typical TEM image shows that the as-prepared FNCPs are spherical in morphology, with an average diameter of 5.2 nm (Fig. 2A). Furthermore, the high-resolution TEM (HRTEM) image (Fig. 2B) shows the lattice plane with an interfringe distance of 0.254 nm, corresponding to the (100) planes of graphitic carbon.47 Besides, the FNCPs have a diffraction peak centred at 22.6° in the typical XRD spectrum (Fig. 2C), indicating that the interlayer spacing of (002) diffraction peak is 0.39 nm. This value is larger than that of graphite (0.34 nm), possibly owing to the existence of oxygen-containing functional groups.48
Fig. 2 Typical TEM image (A), HRTEM image (B), XRD pattern (C), and FTIR spectra (D) of the FNCPs. |
The structures and components of the FNCPs are identified by FTIR and XPS experiments. As illustrated in Fig. 2D, the FTIR spectrum exhibits characteristic absorption bands of O–H and N–H stretching vibrations at 3400 cm−1, C–H stretching vibrations at 2940 cm−1, CO stretching vibrations at 1760 and 1670 cm−1, and CC stretching vibrations at 1590 cm−1.30,49 Moreover, the bands in the range of 1030–1380 cm−1 suggest the presence of a large amount of C–O groups.46 The zeta potential of the FNCPs was measured with a value of −18.3 mV, which further confirms the presence of hydroxyl and carboxylic groups on the surface of the FNCPs.
The XPS spectrum shows three strong peaks at 532.0, 401.1, and 286.1 eV, which are attributed to O1s, N1s, and C1s, respectively (Fig. 3A). These results indicate that the FNCPs mainly contain C (67.46%), O (23.87%), and N (6.88%). The amount of N (6.88%) is higher than the carbon particles reported by Liu et al. and can be used for the surface passivation of carbon particles.31 Specifically, the deconvolution of the C1s spectrum (Fig. 3B) displays four peaks at 288.2, 286.3, 285.6, and 284.6 eV, which are assigned to the CO, C–N, C–O, and CC groups, respectively.29 The O1s spectrum (Fig. 3C) has two peaks at 533.0 and 531.7 eV, which are attributed to the C–OH/C–O–C and C–O groups, respectively.45 The three peaks at 401.5, 400.5, and 399.5 eV in N1s spectrum (Fig. 3D) are come from the N–H, N–(C)3, and C–N–C groups, respectively.50
Fig. 3 The XPS (A), C1s (B), O1s (C), and N1s (D) spectra of the as-obtained FNCPs. |
As shown in Fig. 4A, the fluorescence intensity of the FNCPs remains almost constant in the presence of different concentrations of NaCl (up to 1 M), indicating high stability of the FNCPs even under high ionic strength environment. Meanwhile, varying the pH from 4 to 9 show no effects on the fluorescence intensities of the FNCPs (Fig. 4B), indicating the FNCPs are insensitive to the pH over the entire physiologically range, unlike the carbon particles reported by Shen’s51 and Shi’s52 groups. Furthermore, after irradiation for 7 h by using a 500 W Xe lamp, only a slight change in the fluorescence intensity is observed (Fig. 4C). Similar observation is obtained when the sample is stored for 3 months (Fig. 4D). These results indicate excellent photostability of the FNCPs, probably due to the electrostatic repulsions between the negatively charged nanoparticles. All these properties make the FNCPs particularly valuable for real applications in bio-labelling and bio-imaging.
Fig. 4 (A) The relative fluorescence intensity at 427 nm (excitation at 344 nm) of the FNCPs in the NaCl solution. (B) Dependence of the fluorescence intensity on the pH values from 2 to 12. (C) The variation of the fluorescence intensity of the FNCPs under irradiation by a 500 W Xe lamp for different time intervals. (D) Photostability of the FNCPs as a function of the storage time. |
Fig. 5 Time-dependent fluorescence responses of the FNCPs to 50 μM Hg2+. Inset shows the F/F0 plotted against time in the presence of 50 μM Hg2+, where F and F0 are the fluorescence intensity of the FNCPs at 427 nm with and without Hg2+, respectively. |
The selectivity of the FNCPs to Hg2+ is also examined (Fig. 6), with other 15 metal ions (Ca2+, Ag+, Ni2+, Cr3+, Al3+, Cu2+, Ba2+, Fe3+, Pb2+, Zn2+, Fe2+, Co2+, Mg2+, Mn2+, or Cd2+) tested as control. Hg2+ has the ability to quench the fluorescence intensity obviously, while the other metal ions have little or no quenching effects. Competitive experiments were also carried out to study the influence of other metal ions (Fig. S1†). The quenching caused by the mixture of Hg2+ (50 μM) with the other metal ions (100 μM) was similar to that caused solely by Hg2+ except very little interference of Cu2+. These observations indicate high selectivity of the present fluorescent probe toward the detection of Hg2+, owing to stronger affinity of Hg2+ than other metal ions toward the carboxylic, hydroxyl and amino groups on the surface of the FNCPs.53 Furthermore, thus-formed FNCP–Hg2+ complexes would facilitate charge transfer and restrain the radiative recombination of excitons, leading to distinguished fluorescence quenching effects.20
Fig. 6 Relative fluorescence intensity (F/F0) of the FNCPs in phosphate solutions (25 mM, pH 7.4) with 50 μM different metal ions. F and F0 correspond to the fluorescence intensity of the FNCPs with and without 50 μM of different metal ions. |
In order to understand the interactions between the FNCPs and Hg2+, UV-Vis absorption titration measurements were performed (Fig. S2†). Upon the successive addition of Hg2+, an increase in absorption at 225 nm is observed, indicating the formation of the FNCP–Hg2+ complex.35 The phenomenon is different from that reported by Pal and his coworkers,35 because different functional groups are present on the carbon nanoparticles' surfaces.
Fluorescence lifetime measurements were conducted to gain further insight into the mechanism of fluorescence quenching of the FNCPs by Hg2+. As shown in Fig. 1D, the fluorescence lifetime of the blank FNCPs is relatively high with a value of 7.6 ns, while the lifetime decays to 4.8 ns after the addition of Hg2+. It indicates that the quenching is dynamic, further confirming an ultrafast electron transfer process in the FNCP–Hg2+ system.
Fig. S3† shows the fluorescence response of the FNCPs to 50 μM Hg2+ at various pH values. Evidently, the quenching efficiency is low under acidic media, where the surface binding carboxylic and amino groups are protonated, leading to the dissociation of the FNCP–Hg2+ complex. With the increase of pH, deprotonation of the carboxylic and amino groups occurs, which may strengthen the covalent bond between the FNCPs and Hg2+, resulting in the significant decrease of the fluorescence intensity of the FNCPs. However, further increasing the pH value also causes a low quenching efficiency, because Hg2+ may be complexed by OH− instead of the FNCPs under typical conditions. Furthermore, as mentioned above, varying pH values from 4 to 9 shows no effects on the fluorescence intensity of the system (Fig. 4B). All the results indicate that the carboxylic and amino groups on the surface of the FNCPs play a critical role for the sensitive and selective detection of Hg2+.
The effects of different Hg2+ salts (chloride, nitrate, perchlorate and acetate salt of Hg2+) on the emission of the FNCPs were also investigated. As displayed in Fig. S4,† all the Hg2+ salts display similar quenching effects. As control experiments, none of the Na+ salts used show quenching of the fluorescence, demonstrating that Hg2+ is solely responsible for the quenching.
To evaluate the sensitivity of this system, different concentrations of Hg2+ within 50 μM were studied. As shown in Fig. 7, the fluorescence intensity of the FNCPs is sensitive to Hg2+ and decreases with the increase of Hg2+. The quenching efficiency is fitted to the Stern–Volmer equation, F0/F = 1 + KSV[Q], where KSV is the Stern–Volmer quenching constant, [Q] is the concentration of analyte (Hg2+), and F0 and F are the fluorescence intensities at 427 nm in the absence and presence of Hg2+, respectively. Fig. 7B shows two good linear ranges of 10–100 nM (R = 0.9982) and 1–50 μM (R = 0.9851), respectively. The limit of detection (LOD) is estimated to be 3 nM (at a signal-to-noise ratio of 3), which readily meets the Hg2+ detection requirement for drinking water by the European Union (5 nM, 1 ppb).54
Fig. 7 (A) The fluorescence responses of the FNCPs in a phosphate solution (25 mM, pH 7.4) after the addition of different concentrations of Hg2+ (top to bottom): 0, 0.010, 0.025, 0.050, 0.075, 0.100, 0.500, 1.00, 5.00, 10.0, 25.0, and 50.0 μM. (B) Plot of the F/F0 with the concentration of Hg2+. |
To evaluate the performance of the FNCPs, other fluorescent methods of the detection of Hg2+ were provided for comparison (Table S1†). Evidently, the developed assay is superior, with the advantages of low detection limit and wide linear range, compared with other assays.
To test its practicality, the developed method was extended to determine the concentration of Hg2+ in environmental water samples from the Chuyang Lake on our campus. All the samples were filtered through a 0.22 μm membrane, followed by centrifugation at 15000 rpm for 15 min to remove any suspended particles. The fluorescence intensity of the FNCPs decreases when the samples have been spiked with standard solutions (Table S2†). The recoveries of Hg2+ in the spiked samples are in the range of 97–115%, illustrating little interference of the minerals, organics, and bacteria present in the samples. These results demonstrate that this sensing system has great potential for quantitative detection of Hg2+ in environmental samples.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/c3ra43452d |
This journal is © The Royal Society of Chemistry 2013 |