Issue 8, 2022

Autonomous electrochemical biosensing of glial fibrillary acidic protein for point-of-care detection of central nervous system injuries

Abstract

The integration of electrochemical biosensors into fluid handling units such as paper-based, centrifugal, and capillary microfluidic devices has been explored with the purpose of developing point-of-care platforms for quantitative detection of bodily fluid markers. However, the present fluidic device designs largely lack the capacity of full assay automation, needing manual loading of one or multiple reagents or requiring external devices for liquid manipulation. Such fluidic handing platforms also require universality for detecting various biomarkers. These platforms are also largely produced using materials unsuitable for scalable manufacturing and with a high production cost. The mechanism of fluid flow also often induces noise to the embedded biosensors which adversely impacts the accuracy of biosensing. This work addresses these challenges by presenting a reliable design of a fully automated and universal capillary-driven microfluidic platform that automates several steps of label-free electrochemical biosensing assays. These steps include sample aliquoting, controlled incubation, removal of non-specific bindings, reagent mixing and delivery to sensing electrodes, and electrochemical detection. The multilayer architecture of the microfluidic device is made of polymeric and adhesive materials commercially used for the fabrication of point-of-care devices. The design and geometry of different components of the device (e.g., sampling unit, mixer, resistances, delay valves, interconnecting components) were optimized using a combined experimental testing and numerical fluid flow modeling to reach high reproducibility and minimize the noise-induced to the biosensor. As a proof of concept, the performance of this on-chip immunosensing platform was demonstrated for rapid and autonomous detection of glial fibrillary acidic proteins (GFAP) in phosphate-buffered saline (PBS). The microfluidic immunosensing device exhibited a linear detection range of 10–1000 pg mL−1 for the detection of GFAP within 30 min, with a limit of detection (LoD) and sensitivity of 3 pg mL−1 and 39 mL pg−1 mm−2 in PBS, respectively. Owing to its simplicity, sample-to-result performance, universality for handing different biofluids, low cost, high reproducibility, compatibility with scalable production, and short analysis time, the proposed biosensing platform can be further adapted for the detection of other biomarkers in different clinical bodily fluids for rapid diagnostic and prognostic applications.

Graphical abstract: Autonomous electrochemical biosensing of glial fibrillary acidic protein for point-of-care detection of central nervous system injuries

Supplementary files

Article information

Article type
Paper
Submitted
09 Janv. 2022
Accepted
09 Marts 2022
First published
10 Marts 2022

Lab Chip, 2022,22, 1542-1555

Autonomous electrochemical biosensing of glial fibrillary acidic protein for point-of-care detection of central nervous system injuries

R. Salahandish, M. Hassani, A. Zare, F. Haghayegh and A. Sanati-Nezhad, Lab Chip, 2022, 22, 1542 DOI: 10.1039/D2LC00025C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements