Strip electrodes: a novel, effective and minimally invasive therapeutic option for correcting DNS via electromechanical reshaping

Abstract

Deviated nasal septum (DNS) is a common condition affecting nasal breathing, which is generally treated using septoplasty. However, this invasive surgical method carries potential risks of post-surgical complications. Alternatively, electromechanical reshaping (EMR) is a novel method that has evolved as a non-thermal, minimally invasive option to reshape the cartilage using mechanical pressure and direct current (DC) without significant tissue damage. However, the existing flat and needle electrodes tested in animal tissues have raised significant concerns due to their safety. Thus, herein, we aimed to develop a novel strip electrode configuration and optimize dosimetry to achieve efficient reshaping without compromising its safety. Electric field simulations showed that our novel 5-strip electrode configuration with a thickness of 0.5 mm achieved optimal electric field, requiring minimal current flow compared to flat electrodes. EMR was performed on ex vivo goat cartilage at various dosimetry groups to analyze four-day shape retention. The optimized strip electrode reshaped the ex vivo goat septal cartilage effectively at a dosimetry of 20 mA for 15 minutes, whereas the flat electrode needed 35 mA for 15 minutes. DMMB assay, ATR-FTIR spectroscopy, tensile testing, and histopathology analysis demonstrated reduced tissue damage while supporting increased efficiency and mechanical stability with the strip electrode configuration, emphasizing its safety. Thus, the optimized strip electrode-based EMR emerges as a viable non-invasive approach for reshaping the nasal septal cartilage, which can be used to treat DNS. Further in vivo studies are recommended to validate the long-term safety and efficacy of this technique.

Graphical abstract: Strip electrodes: a novel, effective and minimally invasive therapeutic option for correcting DNS via electromechanical reshaping

Supplementary files

Transparent peer review

To support increased transparency, we offer authors the option to publish the peer review history alongside their article.

View this article’s peer review history

Article information

Article type
Paper
Submitted
15 Jūn. 2024
Accepted
15 Nov. 2024
First published
15 Nov. 2024

J. Mater. Chem. B, 2025, Advance Article

Strip electrodes: a novel, effective and minimally invasive therapeutic option for correcting DNS via electromechanical reshaping

M. J. B. Jahankir, H. Ramesh, T. Chakaravarthi, A. Agarwal, A. Goyal and G. M. Balachander, J. Mater. Chem. B, 2025, Advance Article , DOI: 10.1039/D4TB01306A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements