Characterization of a new ICP-TOFMS instrument with continuous and discrete introduction of solutions

Abstract

In this work, we evaluate the capabilities of a new commercially available inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS) instrument, the icpTOF (TOFWERK AG, Thun, Switzerland), for analysis of liquid samples with a standard pneumatic nebulizer – cyclonic spray chamber sample-introduction system and a microdroplet sample-introduction system. The ICP-TOFMS instrument provides simultaneous, high-speed detection across almost the entire elemental mass range, from around 7–275 amu. The instrument provides a standard mass resolving power (Rm) of ∼2500 and can provide Rm greater than 4000 through the use of collisional cooling prior to the TOF mass analyzer. In standard operation mode (without collision gas), a sensitivity of 60 000 cps ppb−1 is routinely achieved for heavy elements such as U, with two orders of magnitude decrease in sensitivity from high-to-low masses. Limits of detection (LODs) are in the low parts-per-trillion to high parts-per-quadrillion. The data acquisition system of the TOFMS instrument provides a linear dynamic range greater than 106. The native abundance sensitivity of the ICP-TOFMS is 6.5 × 10−4 on an adjacent mass and is characterized by a non-linear sloping baseline beyond the adjacent mass channel. To obtain simultaneous high-dynamic-range detection, post-acquisition peak fitting and baseline subtraction can be used to reduce the effect of peak tailing on adjacent masses. Simultaneous quantification of adjacent isotopes across six orders of magnitude of signal intensity is possible after baseline subtraction. Advantages of ICP-TOFMS are apparent for high-speed transient analysis. Here, we assess the performance of the icpTOF for the multi-elemental analysis of single microdroplets, with specific emphasis on the characteristics of this approach for 100% transport of liquid samples and for the analysis of nanoparticles. Absolute limits of detection are in the attogram range for single droplets and concentration LODs for the detection of ensembles of droplets are competitive with those attained with pneumatic nebulization sample introduction.

Graphical abstract: Characterization of a new ICP-TOFMS instrument with continuous and discrete introduction of solutions

Supplementary files

Article information

Article type
Paper
Submitted
03 Nov. 2016
Accepted
16 Janv. 2017
First published
16 Janv. 2017

J. Anal. At. Spectrom., 2017,32, 548-561

Characterization of a new ICP-TOFMS instrument with continuous and discrete introduction of solutions

L. Hendriks, A. Gundlach-Graham, B. Hattendorf and D. Günther, J. Anal. At. Spectrom., 2017, 32, 548 DOI: 10.1039/C6JA00400H

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements