D. S.
McLagan‡
*ab,
L.
Schwab‡
c,
J. G.
Wiederhold
c,
L.
Chen
a,
J.
Pietrucha
a,
S. M.
Kraemer
c and
H.
Biester
*a
aInstitute for Geoecology, Technical University of Braunschweig, 38106 Braunschweig, Germany. E-mail: david.mclagan@mail.utoronto.ca; h.biester@tu-braunschweig.de
bDepartment of Physical & Environmental Sciences, University of Toronto Scarborough, Toronto, M1C1A4, Canada
cDepartment of Environmental Geosciences, Centre for Microbiology and Environmental Systems Science, University of Vienna, 1090 Vienna, Austria
First published on 4th January 2022
Interpretation of mercury (Hg) geochemistry in environmental systems remains a challenge. This is largely associated with the inability to identify specific Hg transformation processes and species using established analytical methods in Hg geochemistry (total Hg and Hg speciation). In this study, we demonstrate the improved Hg geochemical interpretation, particularly related to process tracing, that can be achieved when Hg stable isotope analyses are complemented by a suite of more established methods and applied to both solid- (soil) and liquid-phases (groundwater) across two Hg2+-chloride (HgCl2) contaminated sites with distinct geological and physicochemical properties. This novel approach allowed us to identify processes such as Hg2+ (i.e., HgCl2) sorption to the solid-phase, Hg2+ speciation changes associated with changes in groundwater level and redox conditions (particularly in the upper aquifer and capillary fringe), Hg2+ reduction to Hg0, and dark abiotic redox equilibration between Hg0 and Hg(II). Hg stable isotope analyses play a critical role in our ability to distinguish, or trace, these in situ processes. While we caution against the non-critical use of Hg isotope data for source tracing in environmental systems, due to potentially variable source signatures and overprinting by transformation processes, our study demonstrates the benefits of combining multiple analytical approaches, including Hg isotope ratios as a process tracer, to obtain an improved picture of the enigmatic geochemical behavior and fate of Hg at contaminated legacy sites.
Environmental significanceUnderstanding mercury (Hg) biogeochemistry at contaminated sites is essential due to the risk they present to local human and environmental health. Furthermore, Hg is a contaminant of global concern due to its environmental mobility as soluble Hg2+ species or volatile elemental Hg. Thus, it is critical that we understand the stability of Hg and processes affecting this stability in soil–groundwater systems at these sites. Our ability to make such assessments is limited by analytical methods; our current knowledge of specific Hg processes and species occurring in the environment is often inadequate. We demonstrate how complementing existing methods with Hg stable isotope analyses improves our understanding of Hg biogeochemical cycling at contaminated sites and in the environment generally. |
While the knowledge of oxidation state is relevant, this alone tells us little about the specific reaction mechanisms and exact compounds, associations, and complexations occurring, which are crucial to understand the nuances of Hg biogeochemical cycling in the environment. Identification of Hg0 across all environmental matrices is of particular importance due to its elevated volatility and long atmospheric residence time; long-range atmospheric transport of Hg0 is the primary means for the global distribution of Hg.7–9 Transport can also occur in aquatic media, and in this instance knowledge of specific speciation is important as the range of solubilities is vast. Cinnabar (HgS) is almost insoluble under most environmental conditions (solubility in water: ≈2 × 10−24 g L−1), Hg0 has a water solubility of ≈5 × 10−5 g L−1, while some mercuric salts are highly water soluble (i.e., Hg2+ chloride (HgCl2): 66 g L−1).7,10
Another key controller of Hg mobility in soil and aquatic systems is the availability and nature of organic matter. Hg has a high affinity to both soil organic matter (SOM) or dissolved organic matter (DOM) particularly with reduced sulphur groups.11–17 Where SOM and DOM concentrations are low, mineral interactions become proportionally more relevant and Hg speciation is closely linked to iron redox processes in such systems.18–20 Clay minerals and metal oxides also provide potential sorption capacity for Hg, but the strength of these interactions can again be impacted by other factors such as specific mineralogy and organic surface coatings.21,22
Despite the importance of Hg speciation and reaction biogeochemistry, current analytical capabilities struggle to identify specific processes and Hg2+ compounds occurring in solid and aqueous matrices, which severely limits our understanding of Hg biogeochemical cycling in natural systems. Hg biogeochemical analyses have thus often focussed on the identification of Hg fractions that are “operationally defined” and unique to individual methods.23,24 The most commonly applied methods of achieving this being sequential extraction protocols (SEP), pyrolytic thermal desorption (PTD), and synchrotron-based X-ray absorption spectroscopy (XAS) techniques. All these methods have inherent strengths and weaknesses that result in limitations in the interpretation of results when used in isolation. The application of SEP is particularly problematic for samples with elevated fractions of Hg0,25,26 there can be matrix related artefacts affecting the distribution of Hg between the extracts,25,27,28 and the fractions of Hg removed in each extraction step are limited to “operationally-defined” pools rather than specific species.24,29,30 While PTD analyses are effective in identifying the presence of Hg0 (released at low temperatures) and Hg2+ sulphides and sulphates (released at high temperatures), most other Hg2+ species, often termed matrix-bound Hg2+, have overlapping release curves (released at moderate temperatures) making it difficult to discriminate specific species.24,25,31,32 XAS methods (e.g., XANES and EXAFS) can provide arguably the highest degree of detail on specific species in a solid-phase sample (oxidation state, coordination geometry, and chemical bonding partners); however, synchrotron measurements are expensive, not widely available, and the detection limits can be prohibitively high (≈100 mg kg−1 Hg, at least for bulk sample techniques) restricting analyses to only highly contaminated samples.24,27,33
Hg stable isotope analyses are still relatively new and represent the multi-tool in Hg scientists' toolbox; the method has relevance to geochemical, atmospheric, hydrological, biological, and even cosmological sciences.34–39 Hg has seven stable isotopes that can be fractionated in the environment by mass-dependent fractionation (MDF) and mass-independent fractionation (MIF).34,35 This can be kinetic isotope fractionation, incomplete transformation of a pool of Hg resulting in the non-reacted pool being enriched in heavier isotopes, or equilibrium fractionation, equal forward and reverse reactions that drive heavier isotopes into “stronger bonding environments”.37 MIF is the deviation in measured stable isotope ratios from the theoretical MDF-based values. MIF of odd-mass Hg isotopes can be caused by both the nuclear volume effect (NVE) and the magnetic isotope effect (MIE).34,35 MIF of even-mass isotopes has also been observed, mostly in atmospheric samples, but a mechanistic understanding of this phenomenon is still lacking.40,41 Large odd-MIF effects found in environmental samples are generally associated with MIE during photochemical processes, but dark reactions have also been demonstrated to impart a MIF of smaller magnitude caused by the NVE under appropriate conditions.42–44 Although Hg stable isotope analysis does not allow the direct identification of specific Hg species, this assortment of different isotopes and fractionation processes provides detailed information about the biogeochemical history of Hg in an environmental sample and has the potential for both source and process tracing.34,35,45,46 We postulate that this novel ability of Hg stable isotopes to trace processes offers great potential to advance Hg geochemistry beyond the current state-of-the-art.
Hg contaminated sites provide unique opportunities to investigate and improve our knowledge of Hg biogeochemistry without concerns of low matrix concentrations of total Hg (THg) increasing analytical uncertainties that can occur at background sites.47 This is particularly pertinent for Hg speciation and stable isotope analyses as dividing the pool of THg by specific species, fractions, or isotopes intrinsically raises the required detection/quantification limits for the Hg analyses in the samples. Hence, they provide Hg scientists with the often termed “field laboratory” – sites to examine Hg biogeochemical processes in greater detail under “real-world” environmental conditions.48,49 From a less utilitarian viewpoint, Hg contaminated sites present acute and chronic risks to human and environmental health. It is essential that Hg speciation and stability and the processes impacting Hg speciation and stability are fully assessed to accurately gauge these risks at Hg contaminated sites.
Utilising multiple analytical methods on the same samples allows the examination of strengths and weaknesses of individual methods that have the potential to increase the quality and detail of information particularly related to Hg transformation processes, but also potentially to Hg speciation. Furthermore, soil–groundwater systems are coupled and highly interconnected, considering the solid and liquid-phases in isolation is atomistic and may result in suboptimal geochemical data interpretations. A holistic assessment should also account for variability in site geography, hydrology, and geology that affect Hg geochemistry. Hence, the purpose of this work is to demonstrate an improved explanation of geochemical assays of Hg at contaminated sites by utilising a suite of analytical techniques (THg concentration, Hg stable isotopes, Hg speciation, and complementary metadata) and data analysis methods in both solid- (soil) and liquid-phase (groundwater) samples.
It is our aim to improve our understanding of Hg geochemistry by examining our ability to assess (i) source information, (ii) transformation processes, (iii) speciation, and (iv) transport. We will apply this approach to examine two former wood kyanisation facilities (treatment of timber with ≈0.66% HgCl2 solution for preservation50,51) in Germany. These sites are ideal for examining Hg biogeochemistry in soil–groundwater systems due to the high solubility of HgCl2, which facilitated leaching into and transport in groundwater bodies. While a multi-method approach itself is not an entirely novel concept in Hg geochemical assessments, such approaches have rarely incorporated Hg stable isotope analyses, and not to the extent and scope of this study. We see Hg stable isotope analyses complemented by existing Hg concentration and speciation analyses as central in obtaining additional insight into the transport, transformation, and fate of mercury provided by previous Hg biogeochemical assays at these and other study sites. In addition, we aim to identify Hg transformation processes that have been shown to induce Hg stable isotope fractionations in laboratory-based experiments in environmental settings.
Site B is situated on the outskirts of a town (≈235 m above sea level) on the flood plains of the Rhine River. The study area is flat (mean gradient: 0.8%) and there is a single groundwater layer that has a uni-directional flow to the NNE. The kyanisation facility covered an area of approximately 9 ha and operated from 1904–1965.53–55 During this time, an estimated 10–20 t of Hg was released to the soil and groundwater system.53,54 A full description of the site geology is provided in Section S1.† The Hg contamination plume in the aquifer has been previously reported to extend approximately 1.3 km from the former industrial facility.54 Persistent below average rainfall during the sampling period in this area led to declining and low (lowest levels in previous 17 years) groundwater levels during the sampling campaign. Groundwater depths for the different wells at site B are presented in Sections S3 and S4† describes the mean historical and sampling period climate graphs at nearby weather stations.
Three soil cores were also taken at site B: soil core B1 (SCB1), soil core B2 (SCB2), and soil core B3 (SCB3). SCB1 is beneath the former kyanisation building, SCB2 is at the edge of the former industrial facility land, where contaminated surface materials were reportedly deposited to construct an embankment, and SCB3 is ≈600 m along the contaminated groundwater plume from SCB1, where there were no known contamination inputs at the top of the soil profile (Fig. S1.2†). Solid-phase samples were then transported in closed polypropylene containers from the field to the laboratory and stored at 4 °C until analysis or extraction. All solid-phase THg concentrations are reported on a dry weight (dw) basis. Fig. S1.2† shows the locations of the 17 groundwater wells sampled at Site B. These extend along the groundwater Hg plume from the site of the former kyanisation building (WB3) to a cluster of four wells (WB23, WB24, WB17, and WB29) at the end of the plume (≈1000 m from WB3), where THg concentrations in the groundwater reach background levels (0.1–0.5 μg L−1)54 (Fig. S1.2†).
Groundwater samples at both sites were extracted with a groundwater pump (Comet-Combi; Comet-Pumpen) using 10 mm inner diameter PTFE tubing. Well volume was exchanged three times before sampling occurred. Sampled groundwater for Hg liquid-phase speciation was collected in cleaned (soap-free distilled water dishwasher at 60 °C, triple rinsed with distilled water, triple rinsed with sample water before collection) 300 mL polypropylene bottles. Sample bottles were filled to capacity with minimal possible headspace to minimise gas-phase exchange. Sample bottles were then stored at 4 °C until return to laboratory for processing (<96 h for all samples). Samples for THg and Hg stable isotopes were collected in 50 mL polypropylene vials, stabilised with 1 vol% bromine–chloride (BrCl, prepared according to Bloom et al.26) after filtration with 0.45 μm cellulose acetate (CA) membrane filters in the field and transported to the laboratory where they were stored at 4 °C until analysis. A full description of groundwater well locations, sampling times, and methods is provided in Section S1.†
We identified individual peaks using peak fitting software based on Gaussian (normal) peak shapes (OriginPro 2018 v9.5). We acknowledge the elevated difficulty and uncertainty in identification and quantification of individual Hg2+ species (release peaks > 175 °C) due to species with overlapping peaks and possible matrix effects that may alter peak release temperature and peak shape (non-Gaussian).25,31,32 We deem peak fitting, identification, and quantification of Hg2+ species to be qualitative analyses (see Section S5† for details). However, the high volatility of Hg0 results in it being released early in PTD analyses (<175 °C) with little-to-no overlap with Hg2+ species (Fig. 1); therefore, Hg0 can be quantitatively or at least semi-quantitatively assessed. Details of the nature of these assessments are given in Section S2.† The reported PTD signal attenuation data are normalised to the maximum attenuation in each measured replicate and then presented as the mean value of all measured replicates for each sample (between 2 and 10 replications).
SEP speciation analyses were also investigated in selected solid-phase samples. This method followed what is described in Brocza et al.55 Briefly, F1 is the water extractable fraction (deionised water: 18.2 MΩ cm) and targets soluble species such as HgCl2 and DOM bound Hg.26,55 F2 targets “labile, bioavailable Hg” weakly sorbed species such as those associated with carbonates using a weak acid (0.5 M HNO3).55,56 F3 uses a stronger acid (6 M HNO3) to extract more tightly bound species.55,57 F4 uses the strongest acid strength (aqua regia) to remove the remaining most stable, sulphide-bound species (α-HgS and β-HgS).26,30 Please note that compared with the widely used SEP by Bloom et al.,26 we omitted the 1 M KOH step targeting organo-chelated Hg species due to their low abundance in most of our field samples, increased the acid strength of the F2 step to account for the high buffer capacity of the carbonaceous sample material, and decreased the molarity of the HNO3 extract from 12 M to 6 M to avoid potential dissolution of very fine-grained HgS phases following Hall et al.57 as already discussed in Brocza et al.55 Tests were run that included this omitted step on selected samples. The relative Hg fraction of the omitted step was low, which supports the hypothesis that sorption to SOM plays a minor role in these soils (see Section S2† for details on these tests).54
Some of the “species” identified by both PTD and SEP analyses are not individual Hg species but rather two or more specific species or “fractions” that behave similarly under varying temperature and extractant strength, respectively. “Fractionation” analysis has also been used to describe these methods.30,58 We acknowledge this but have chosen to use the term “speciation” analyses for both PTD and SEP for consistency with the majority of the literature and to avoid confusion with Hg stable isotope fractionation also investigated in this study.
Mercury species in liquid-phase samples (groundwater) were determined by the method outlined by Bollen et al.54 and Richard et al.20 using a Hg-254 Analyzer (Seefelder Messtechnik). This method produces a total of four distinct fractions in addition to THg: (i) Hg0 (purged from untreated sample), (ii) dissolved inorganic Hg2+ (Hg2+A; purged after reduction with SnCl2 treatment; e.g. HgCl2); (iii) DOM-bound Hg2+ (Hg2+B; purged after BrCl and SnCl2 treatment), and (iv) particulate Hg (Hg-part; difference between total filtered and total unfiltered). Liquid-phase speciation analyses are deemed qualitative (see Section S2†).
Measurements were made with a Nu Plasma II (Nu Instruments) multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) connected to a HGX-200 cold vapour generator (Teledyne Cetac). Instrumental mass bias was corrected by standard sample bracketing with NIST-3133 and Tl doping using NIST-997 introduced by a Aridus 2 desolvating nebulizer (Teledyne Cetac). Mass-dependent fractionation (MDF) uses δ notation and is reported as permil (‰) values relative to NIST-3133 according to eqn (1):
(1) |
Mass-independent fractionation (MIF) uses Δ notation and describes fractionation away from the expected MDF according to eqn (2)–(5):
Δ199Hg = δ199Hg − (δ202Hg × 0.2520) | (2) |
Δ200Hg = δ200Hg − (δ202Hg × 0.5024) | (3) |
Δ201Hg = δ201Hg − (δ202Hg × 0.7520) | (4) |
Δ204Hg = δ204Hg − (δ202Hg × 1.4930) | (5) |
Our “in-house” secondary standard, ETH Fluka, was used to assess the accuracy and precision of measurements. Results (see Section S2†) were consistent with previous studies in this and other laboratories and details are provided in Section S2.†55,61–66 Analytical precision (2 SD) is reported with the measured values based on the standards run during each session (see results and discussion and Sections S2, S3, S6, and S7†). No significant even-mass MIF anomalies (Δ200Hg and Δ204Hg) outside of the analytical precision were generally detected in the samples of this study.
Fig. 3 Multi-analyses summation of SCA2 solid-phase material. (a) THg and Hg0 concentration (logarithmic scale) and SEP speciation data. (b) PTD speciation data – all signal attenuations are normalised to the maximum attenuation for each sample. (c) δ202Hg (MDF) stable isotope data of bulk sample and SEP extracts. This core extends to −19.5 m; however, THg concentration are relatively constant and low (0.09 ± 0.03 mg kg−1) and δ202Hg values are relatively constant at −1.0 ± 0.2‰ for samples between −16.5 and −19.5 m (see Table S6.2† for data below 16 m). |
Hg concentrations were higher in subsurface samples than surface samples in all soil cores at both sites and when comparing the subsurface sample SSA11 (THg: 41.5 mg kg−1) to topsoil sample TSA11 (THg: 2.8 mg kg−1) (Section S6†). The maximum THg concentration of SCA1, SCA2, and SCA3 were 20.2 (at −1.5 m; Fig. 2), 50.0 (at −6.5 m; Fig. 3), and 133 (at −1.5 m; Table S6.3†) mg kg−1. The maximum solid-phase concentration at site B was 562 mg kg−1 at −2.75 m in SCB1, which is below the former kyanisation building (Fig. 4). There is evidence of minor surface contamination in SCB2 and discussions with consulting agencies working at this site suggest contaminated materials were used to construct a small embankment in the area of this core. Nonetheless, THg concentrations were significantly higher in the aquifer than the vadose zone in this core (p < 0.001). These data suggest Hg leaching down soil profiles (see Section 3.2.4) and/or removal or burial of surface material from industrial period has occurred at both sites.
Fig. 4 Multi-analyses summation of SCB1 solid-phase material. (a) Description of approximate soil core layer profile is based on our own visual characterisation and literature descriptions.53–55 (b) THg and Hg0 concentration (logarithmic scale) and SEP speciation data. (c) PTD speciation data – all signal attenuations are normalised to the maximum attenuation for each sample. (d) δ202Hg (MDF) stable isotope data of bulk sample and SEP extracts. This core extends to −17.25 m; however, THg concentrations are relatively constant and low (0.04 ± 0.03 mg kg−1) and δ202Hg values are also relatively constant and highly negative (−2.4 ± 0.3‰) for samples between −10.25 and −17.25 m (see Table S6.5† for data below 10 m). |
At both site A and site B, maximum liquid-phase (groundwater) concentrations are spatially offset from the maximum solid-phase concentrations and the location of former industrial buildings. At site A, the highest liquid-phase THg concentrations were consistently observed in WA7, WA10a, and WA10b on the northern side of the river (Table S3.1†) and are suggested to be down-aquifer from the former sawmill.20 Richard et al.20 also reported peak THg concentrations in well WA7 (labelled W2 in their study). All wells on the southern side of the river at site A had consistently lower THg concentrations than WA7, WA10a, and WA10b.
Similarly at site B, the highest groundwater THg concentrations were not observed at wells closest to the former kyanisation building (WB3 or WB7), but further along the relatively uniform groundwater flow path in wells WB10, WB8, WB19 and WB20, the latter of which (WB20) is located ≈700 m from the former kyanisation building. Data from both sites supports the previously posited notion of soluble Hg leaching down the soil profiles and being transported within the aquifer.54 This will be discussed in more detail in Section 3.2.
The regional background δ202Hg value at both sites appears to be depleted in heavier isotopes to a greater extent. A fine fraction (<2 mm) sediment sample collected ≈1 km upstream of the contaminated area at site A (THg concentration: 0.006 mg kg−1 dw) had a low δ202Hg of −2.27 ± 0.11‰. Although these are river sediments and not soils, their inputs are erosion of catchment soils upstream from the contaminated site; and hence we expect the δ202Hg values of these uncontaminated soils to be similar to the highly negative sediment material. Similarly, weathered sedimentary deposits of the lower part of the aquifer in SCB1 that we suggest are unaffected by surface contamination (THg: 0.075 mg kg−1 dw; δ202Hg: −2.3 ± 0.4‰, 1 SD; Table S6.5†), and the vadose zone of SCB3 (samples above −5 m), an area of site B with neither industrial Hg surface contamination nor inputs from the contaminated aquifer are highly enriched in lighter isotopes (THg: 0.08 ± 0.04 mg kg−1; δ202Hg: −2.77 ± 0.84‰, 1 SD). Even considering the negative end of the uncertainty range of the mean δ202Hg value of Hg ore minerals, the regional background MDF signature based on these samples unaffected by industrial contamination is more negative. Therefore, it is possible to conduct a general source appropriation or mixing modelling using a multidimensional analysis that includes THg concentration and δ202Hg. There is a significant negative relationship between δ202Hg and 1/THg that confirms more contaminated samples generally exhibit less negative δ202Hg values (Fig. 7). Nonetheless, any kinetic (or equilibrium) transformation process (i.e., sorption of liquid-phase Hg2+ to the solid-phase; see Section 3.2.1) will fractionate Hg isotopes to favour lighter isotopes in the reacted or “products” pool. Due to isotope fractionations caused by in situ transformation processes and the large range of possible δ202Hg values of Hg stock material we can only recommend using such source appropriation in general terms and not on a more quantitative, sample-per-sample basis.
The MIF signature of global Hg ore minerals is more constrained; and hence, we can estimate the potential MIF industrial source signature more accurately. Mean Δ199Hg MIF signatures from individual soil cores, topsoils, and groundwater wells range from −0.11 to 0.00‰ (Sections S3 and S6†). In addition to the global mean, Grigg et al.63 also report the mean Δ199Hg MIF from European commercial ores as being more negative −0.06 ± 0.11‰ and suggest this value is more appropriate for European Hg usage. Considering our observed Δ199Hg values fall on either side of the European ore value, it may also be the most appropriate MIF industrial source signature at our sites. We generally observed only relatively small Δ199Hg and Δ201Hg variations in our samples. Mean Δ199Hg values with 1 SD range at site A were −0.01 ± 0.06‰ in the solid-phase materials and −0.07 ± 0.02‰ in groundwater. At site B these values were −0.03 ± 0.05‰ (solid-phase) and −0.10 ± 0.02‰ (groundwater), respectively. These data include samples with very negative δ202Hg values characteristic for “background” Hg. Thus, we could not define different MIF mixing endmembers in our dataset (see Fig. S6.1† for plot of Δ199Hg against δ202Hg in all solid phase samples).
Overall, characterisation of the Hg isotopic source signature at legacy contaminated sites remains a challenge. It is difficult to obtain and characterize the isotopic signature of the Hg stock (with potentially variable sources),63,69 and on-site transformation processes (including during preparation and use of HgCl2 solution from Hg0 stock) are likely to have shifted isotopic source signatures of measured samples away from that of the stock material. It is likely Hg stable isotopes are a more effective tool for tracing processes rather than sources at our field site and their application in the characterisation of Hg geochemical processes will be examined in the next section.
HgCl2 could also dissociate to a HgCl+ ion under liquid-phase equilibrium with the ionic species preferentially sorbing to the solid-phase.79 Yet, the fraction of HgCl+ formed at neutral pH and 0.5 M Cl− concentration is only 0.006% (HgClOH, Hg(OH)2, and HgCl2 are expected to be the dominant species in solution based on these experiments).79 Hence, direct HgCl2 sorption to the solid-phase (and/or diffusion into the mineral matrix) may be the more dominant mechanism.
The most contaminated section of any soil core across both sites are the lower “artificial-filling” layers of redeposited soil material/building rubble in SCB1 (samples −1.25 to −3.25 m; Fig. 4). The pH of these layers is high, particularly between −1.75 m and −3.25 m (pH: 11.1 to 11.4; sample −1.25 m has pH of 8.7; Table S6.5†) and potentially associated with building materials such as concrete. Fe and Mn oxide formation can increase at higher pH.76,81,82 Thus, pH, the presence of Fe and Mn minerals and their greater stability in oxidised forms at the high pH of these lower artificial filling layers, and the reduced permeability of the underlying loess layer are likely important factors contributing to the elevated accumulation of Hg observed between −1.25 and −3.25 m in SCB1. There may also be some unknown sorption capacities associated with the building materials themselves that are anthropogenically derived materials (e.g. concrete) rather than natural minerals.
During initial contamination, the uptake process would have been kinetically controlled as an abundance of HgCl2 in solution sorbed (directly or indirectly) to available surfaces. As solid-phase sorption sites are filled, thermodynamics will become the dominant controller of Hg exchange between the solid- and liquid-phases. Both processes are expected to cause an increase in δ202Hg in the liquid-phase as lighter isotopes preferentially sorb to the solid-phase.37,79,83 Samples in the high concentration lower artificial filling layers in SCB1 (−1.25 to −3.25 m; δ202Hg: −0.17 ± 0.09‰ 1 SD) exhibit lower δ202Hg values compared to both the surface sample (−0.25 m; δ202Hg: 0.49‰) and the low permeability loess layer (−3.75 and −4.25 m; δ202Hg: 0.25 and 0.44‰, respectively) and the Rhine sediment layer down to the aquifer (−5.25 to −8.25 m; δ202Hg: 0.23 ± 0.10‰ 1 SD§) (Fig. 4). The surface sample (−0.25 m) could be enriched in heavier isotopes due to (photo)reduction and evaporative losses.84 We relate the difference in δ202Hg between the high concentration artificial filling layers (more negative) and its underlying layers (more positive) to kinetic and/or equilibrium fractionation resulting in a preferential retention of lighter isotopes in the solid-phase of the lower artificial filling layers and enrichment of the liquid-phase Hg leaching into the underlying layers in heavier isotopes.
While THg concentrations are significantly lower in both the loess and Rhine sediment layers of SCB1 (p < 0.001), they are >2 mg kg−1 in all samples except the uppermost sample of the Rhine sediments (−4.75 m; see footnote§). Hence, the loess layer is of lower permeability, but not impermeable, allowing vertical Hg transport further down the soil core. Due to removal of lighter isotopes during sorption in the overlying artificial filling layers, we would expect the pool of liquid-phase HgCl2 slowly leaching through the loess layer to be enriched in heavier isotopes. This would result in a positive shift in δ202Hg of Hg sorbed to the solid-phase materials of the loess and Rhine sediment layers when compared to the artificial filling layers associated with sorption from this now heavier liquid-phase Hg pool, agreeing with the observed data.
Equilibrium isotope fractionation between Hg0 and Hg2+ results in more positive δ202Hg values in the Hg2+ pool,83,85,86 which could play a role in the observed Hg stable isotope data in SCB1. The δ202Hg value of the bulk sample will become more positive only if there has been Hg0 loss from the solid-phase (evaporation unfavourable in subsurface samples). Hg0 peaks were not observed in all samples of the SCB1 core and the largest fractions of Hg0 in SCB1 occurred at the bottom of the artificial filling layers (Fig. 4 and Section 3.2.3). For Hg0 production and loss to be responsible for the more positive δ202Hg in the loess and Rhine sediment layers we must assume: (i) substantial proportions of Hg0 must have been lost from the solid-phase of these layers (some with no evidence of solid-phase Hg0), and (ii) Hg0 losses in the artificial filling layers (in samples with both large and small Hg0 fractions) must have been small enough as to not impact the δ202Hg value in these layers. We deem this unlikely. Hence, we suggest the more negative δ202Hg values of the highly contaminated artificial filling layers are predominantly driven by fractionation associated with preferential sorption of lighter isotopes to the solid-phase.
When we consider the more contaminated samples from cores across both sites (>1 mg kg−1), the mean fraction of THg extracted in F2 is 26 ± 22% and individual samples range up to 66% in this fraction (Section S7†). The 0.5 M HNO3 extraction is likely to remove a large fraction of the remaining solid-phase bound Hg exchangeable by water, but we cannot confirm complete removal is achieved in F2 without laboratory examination (i.e., repeated/sequential F2 extractions), which should be assessed in future studies. Considering the industrial source is HgCl2 in solution and the incomplete extraction of all extractable labile Hg in F1, this limitation makes it very difficult to distinguish F1 from F2. The difference between the amount of Hg exchangeable by water released in F1 and F2 is likely associated with the strength of sorption or complexation with mineral surfaces and potential re-sorption during or after the F1 extraction step. For the studied systems, F1 is better described as Hg easily exchangeable by water and F2 as Hg less extractable by water plus weakly complexed species (i.e., Hg associated with carbonates), and potentially HgO and HgSO4.26,56,57
In PTD analyses, there is a range of moderate temperatures (175–300 °C based on our data and instrumental setup) in which the release curves of a number of Hg2+ species reach their maximums; Biester and Scholz25 refer to this as “matrix-bound Hg”. All samples analysed by PTD have at least one clearly defined peak within this range. However, the PTD peak fitting analyses indicate wider and oddly shaped matrix-bound Hg peaks (multiple peaks within this range; Section S5†) or a matrix-bound Hg peak that is shifted from the lower end of the range (175–220 °C; HgCl2 release range) to the upper end of this range (250–300 °C) in some samples (e.g., confined aquifer samples from SCA2 and SCA3) (Fig. 2–6 and Section S5†). Additionally, there are samples at both sites with a “shoulder” peak > 300 °C within all soil cores (e.g., aquifer samples from SCA2, SCB2 and SCB3) (Fig. 2–6 and Section S5†). Matrix-bound Hg peaks closer to 300 °C and shoulder peaks > 300 °C indicate a change in chemical speciation from the original HgCl2 contamination to species produced in situ such as associations with pyrite, HgSO4, and meta-cinnabar (β-HgS) species (Fig. 1; see also Biester and Scholz25). There can be matrix effects (changes in mineralogy within a single core, between cores, or between sites) in PTD analyses that can lead to some variability in the release curves of certain species.31,32 However, we observe a weak, but significant positive relationship (p = 0.008; R2 = 0.129) between the F3 fraction (more residual species) and the temperature of the maximum signal attenuation between the temperature range for matrix-bound Hg peaks (175–300 °C) based on all data from the contaminated soil core samples (>1 mg kg−1; Fig. S7.1†). This gives us confidence that shifts in the matrix-bound Hg peaks between 175 to 300 °C are not merely associated with analytical imprecision and peaks closer to 300 °C are likely to be representative of an increase in the fraction of non-HgCl2 Hg species formed in the soil column present in the sample. Nonetheless, this does not completely rule out matrix effects in the PTD analyses, which may still contribute some uncertainty to the exact release temperatures of different species in the PTD analyses.
Fig. 5 Multi-analyses summation of SCB2 solid-phase material. (a) Description of approximate soil core layer profile is based on our own visual characterisation and literature descriptions.53–55 (b) THg and Hg0 concentration (logarithmic scale) and SEP speciation data. (c) PTD speciation data – all signal attenuations are normalised to the maximum attenuation for each sample. (d) δ202Hg (MDF) stable isotope data. Excavation for pump and treat prevented sampling at top of core. |
Fig. 6 Multi-analyses summation of SCB3 solid-phase material. (a) Description of approximate soil core layer profile is based on our own visual characterisation and literature descriptions.53–55 (b) THg and Hg0 concentration (logarithmic scale) and SEP speciation data. (c) PTD speciation data – all signal attenuations are normalised to the maximum attenuation for each sample. (d) δ202Hg (MDF) stable isotope data. |
Fig. 7 Multi-dimensional source appropriation analyses using δ202Hg values and the reciprocal of THg concentrations from solid-phase samples for both site A and site B. Site A topsoils were not included in source appropriation modelling at the site due to surface related processes that cannot occur to soil core samples; however, the model was (weakly) significant even if they were include with site A soil core samples (p = 0.010). Please note, these are linear mixing models on a log-based x-axis; linear-fitted models are expected in plots of delta values vs. the inverse concentration.71 |
The relevant question to be asked is: can these SEP stable isotope results be used quantitatively or are they of a more qualitative nature? One source of uncertainty for stable isotope analyses on SEP extracts may be the extraction of certain Hg2+ species in differing SEP fractions due to variable physicochemical properties and mineralogy of the solid-phase matrix that have been reported.25,27,28 When examining more residual Hg species using SEP analyses (F3 and F4), the pH of soils must be considered. The very high pH between −1.75 and −3.25 m in SCB1 (11.1 to 11.4; Table S6.5†) has already been discussed in relation to the potential increase in Hg2+ sorption to Fe and Mn oxides in this section of the soil profile. SEP results show 17 ± 6% of THg is extracted in the labile (F1/F2) fractions, 19 ± 6% in F3, and 64 ± 6% in F4. The weak acid extraction used in F2 may be buffered by the high soil pH in some of our samples, partially neutralising the extractant acid, and resulting in more Hg being extracted in the subsequent extraction steps (F3 and F4). However, we used a stronger F2 extractant (0.5 M HNO3) to specifically account for the high carbonate content in samples at these sites.55 Experiments examining pH changes of extractant solution confirmed F2 was largely unaffected by high pH solid-phase materials (see Section S2† for details).
These extraction steps are dividing substantial proportions of the THg in each sample and it is possible the extraction processes themselves are imparting some analytical artefact on the observed proportions of stable Hg isotopes. Although Brocza et al.55 suggest differences in Hg stable isotopes in extracts are process driven, they also discuss how site-specific factors (i.e., Hg speciation, soil matrix, or original contamination speciation) may have an effect on the results. We suggest this may go further: changes in the physicochemical properties and/or mineralogy of the solid-phase, which can affect the composition of species extracted in specific SEP fractions,25,27,28 have the potential to impact the observed stable isotope signatures of each SEP fraction. Considering the heterogeneity of Hg within contaminated soils,7,92 the recoveries of the sum of SEP extracts against THg concentrations of the same sample (samples > 1 μg kg−1) are acceptable (97 ± 23%, n = 70; Section S7†). Nonetheless, based on all data with measured stable Hg isotopes in SEP extracts there is a small systematic bias towards heavier isotopes when comparing the δ202Hg values from the bulk sample to the sum of SEP extracts (normalised to extract Hg concentration; mean difference is δ202Hg +0.11 ± 0.26‰ in ΣSEP extracts).
The largest discrepancy in δ202Hg values between bulk and ΣSEP extracts occurs within the confined aquifer in SCA2 (δ202Hg in ΣSEP extracts: +0.44‰ at −6.5 m and +1.48‰ at −7.5 m). These two samples contain very large fractions of Hg0 as evidenced by PTD release peaks at ≈100 °C (Fig. 3 and 8). Due to its volatility, Hg0 is highly unstable and prone to evaporative losses during sampling and storage.25,93 Evaporative losses of Hg0 enriches the substrate in heavier isotopes.70,94 These particular SEP extractions were performed ≈18 months after sampling while the aqua regia digestions for THg and PTD analyses of SCA2 were performed within one month of sampling. SCB1 and SCB3 were again measured within one month of sampling for THg digests and PTD analyses, but SEP analyses were performed 4-5 months after sampling. It is highly likely that increased evaporative losses of Hg0 during the extended sample storage of SCA2 are responsible for the majority of the heavy isotope enrichment observed in these ΣSEP extracts. Removing these two samples in SCA2 (−6.5 and −7.5 m) improves the comparison between δ202Hg values from the bulk sample to the sum of SEP extracts (mean difference becomes δ202Hg +0.07 ± 0.15‰ in ΣSEP extracts) but does not completely remove this positive δ202Hg bias in the SEP extracts.
It has been demonstrated that Hg0 in solid-phase samples is not removed in a single extraction step but rather “smeared” across potentially all fractions.25,26 This issue becomes increasingly more problematic with increasing Hg0. It is notable that the δ202Hg values from all four SEP extracts in both samples (SCA2: −6.5 and −7.5 m) with large suspected loss of Hg0 during extended storage before analysis are shifted positive compared to the δ202Hg signature of the bulk sample (Fig. 3). This suggests Hg0 loss from all extraction steps and supports the notion that Hg0 is “smeared” across all extraction steps. Hence, there is potential for this “smearing” to artificially alter the ratios of Hg stable isotopes (δ202Hg value) in the extracts of each of the SEP extraction steps. Not being able to identify release of Hg0 in a single fraction also means δ202Hg changes associated with Hg0 production or equilibrium exchange between Hg0 and Hg2+ would not be observable in stable isotope analyses of SEP extracts. Considering these matrix (i.e., changing solid-phase properties and mineralogy) and species-specific effects (i.e., Hg0 smearing) on Hg stable isotope analyses of SEP extracts we view this as a complementary qualitative tool for Hg geochemical analyses that has potential to aid in the identification of in situ transformation processes rather than a means of quantitative assessment.
Peak identification and integration analyses were applied to estimate the fraction of Hg0 (out of THg), and from this, the Hg0 concentration in samples where it is present. The observed Hg0 fraction (in THg) ranged from <1 up to 41.7% in SCA2 −7.5 m and 43.7% in SCB1 −3.25 m (Fig. 8 and Section S5†). Elevated Hg0 and THg concentrations, especially in SCB1 −2.75 and −3.25 m, but also SCA2 −6.5 and −7.5 m, result in very high Hg0 concentrations up to 187 mg kg−1 (Fig. 8 and Section S5†). These results confirm PTD analyses as an effective tool for identification of Hg0 in solid-phase samples.
Abiotic reduction of Hg2+ can be facilitated by electron transfer from organic matter or most other less precious metals. The oxidation of Fe2+ or mixed valence (Fe2+/Fe3+) iron oxide minerals such as magnetite,102,106 siderite,107 vivianite,108 green rust,109 and clay minerals110 are likely to drive much of this reduction due to their relatively high abundance. This process can be expedited under anoxic or suboxic conditions within which such ferrous iron containing minerals become important electron donors.19,20,111 The fluctuating water table depth, oxygenation, and redox condition of these sites, particularly site A, are likely to have played a significant role in Hg0 production in the capillary fringe and upper aquifer.
Wiatrowski et al.102 and Amirbahman et al.112 demonstrated the importance of pH in this process; Hg2+ reduction is enhanced at higher pH. There were five samples with >10% Hg0 fraction: SCA2: −5.5, −6.5, and −7.5 m and SCB1: −2.75, and −3.25 m; additionally, sample SCB1 −2.25 m (4.6% Hg0) had a high Hg0 concentration of 12.2 mg kg−1 (Fig. 8). Based on the observed groundwater depth data from WA6a, we estimate these samples in SCA2 (−5.5, −6.5, and −7.5 m) to be at the top of the confined aquifer and pH values of the solid-phase materials were 7.40 ± 0.02. In samples directly below these (between −8.5 and −14.5 m), the pH dropped to 5.91 ± 0.02 (Table S6.2†). Similarly, the samples from SCB1 were from the lower artificial filling layer that had a very high pH of 11.3 ± 0.1, while the pH of the loess layer and Rhine sediments below this layer dropped to mean values of ≈7.9 and 6.8 ± 0.2, respectively (Table S6.5†). Thus, the elevated pH in these samples may be contributing to the increased production of Hg0 in these parts of the soil–groundwater systems. Given the low solubility and high volatility of Hg0 (Henry's law constant: 2.3 × 10−8 Pa−1 at 298 K (ref. 113), it can be expected that there will be Hg0 outgassing from contaminated aquifers containing Hg0 into soil cavities.
Hg2+A (dissolved inorganic Hg2+) fraction dominated the liquid-phase speciation analyses (68 ± 14%) across all sampled wells at site B (and site A: 71 ± 21%). Based on the range of pH and redox conditions (Section S3†) and original Hg usage, we consider HgCl2 to be the dominant Hg2+A species as has been reported previously.54 These data also support the inference that SOM plays only a minor role in solid-phase sorption. If SOM played a more integral role in sorption, we would expect Hg2+B (DOM-bound Hg2+) to dominate liquid-phase speciation.
During the “ponding” events, HgCl2 in solution would likely have been transported away from the former kyanisation building down the slight gradient of the site above the loess layer.54 Groundwater THg concentrations in the well closest well to SCB1, WB3 (≈120 m along groundwater flow path from SCB1), are elevated (Table S3.1†). Hence, Hg must be able to (or at least in the recent past) leach into the aquifer between SCB1 and WB3. This could be the result of breaks in the loess layer, potentially caused by site construction, and/or thinning of the loess layer to the point where substantial Hg could leach through it.
The liquid-phase δ202Hg values are generally more positive – enriched in heavier isotopes – compared to the solid-phase samples at site B. Hg losses from the groundwater have resulted in a significant negative relationship between δ202Hg and THg concentration (Fig. 9). Essentially, soluble Hg (i.e., HgCl2) transported away from the most contaminated part of the aquifer become progressively more enriched in heavier isotopes, supporting the notion posited in Section 3.2.1 that sorption from the liquid-phase to the solid-phase enriches the solid-phase in lighter isotopes. This fractionation to heavier isotopes should be enhanced when we consider that Hg2+ species are also enriched in heavier isotopes by equilibrium isotope fractionation between Hg0 and Hg2+.85,86 Thus, evaporative losses of Hg0 from the solid- or liquid-phase to soil airspaces or even groundwater well shafts would result in further enrichment of remaining solid and liquid-phase pools in heavy isotopes.
Fig. 9 Comparison of mean Hg stable isotope values and THg concentrations in liquid-phase samples from site B groundwater across sampling events. Panel (a): relationships of δ202Hg (blue circles) and Δ199Hg (red triangles) against THg concentration. Panel (b): MIF (Δ199Hg) plotted against MDF (δ202Hg) with the blue text representing the mean THg concentrations (μg L−1). Error bars are 1 SD values for both MIF and MDF across the different sampling events. 2 SD analytical precision data are presented in Sections S2 and S3.† |
Bollen et al.54 observed maximum THg concentrations in the same wells, but concentrations were generally ≈2–3× higher than our data in those wells. In July 2018, a pump-and-treat facility was installed to remove Hg from the groundwater at the site. Groundwater concentrations decreased by 1.2 to 6.4× from sampling before the installation to sampling after. Additionally, the summers in both 2018 and 2019 were exceptional hot and dry (groundwater depth at lowest level in previous 17 years). The dry conditions and lower water table mean there was little-to-no exchange between the groundwater and parts up the soil profile that have previously been within the aquifer during the sampling campaign at site B. We describe this area (approximately 1.5–2 m above the water table) generally as the “capillary fringe”. This “capillary fringe” is a section of the soil profile in all three site B cores with elevated labile SEP fractions of solid-phase materials (Fig. 4–6). In both SCB2 and SCB3 both THg concentration and the proportion of THg made up by F1 of the aquifer capillary fringe are elevated and group away from samples from the vadose zone and the aquifer proper (Fig. 10). The lower proportion of F1 within the aquifer is likely a result of this Hg easily exchangeable by water (i.e., weakly sorbed HgCl2) being transported along the groundwater flow path (or transformed into a less soluble species). During historical periods of higher groundwater levels, the Hg groundwater plume would transport soluble Hg into the capillary fringe. Once the groundwater level decreases, a fraction of this soluble Hg would remain in the capillary fringe (as Hg easily exchangeable by water) and not be flushed away as continually occurs within the aquifer proper. We aim to examine these data in greater detail in a future experimental and modelling study addressing Hg transport in the aquifer at site B.
The most noticeable Δ199Hg MIF across the systems is the significant positive shift when comparing liquid-phase samples to solid-phase samples at either site A (Δ199Hg shift: +0.05‰; p < 0.001) or site B (Δ199Hg shift: +0.06‰; p < 0.001). Zheng et al.44 describe the potential for a negative Δ199Hg MIF shift in the Hg2+ pool during Hg(0)–Hg(II) equilibrium fractionation after dark, anoxic Hg0 oxidation in the presence of thiol-groups associated with SOM and moisture. Small MIF shifts in the opposite direction to the MDF shift are expected for any process influenced by the nuclear volume effect, such as equilibrium isotope fractionation between co-existing Hg(0) and Hg(II). Recent studies revealed that the exchange kinetics of this process are surprisingly fast,86,114 suggesting that equilibrium Hg isotope fractionation between Hg redox states can be expected to be relevant in all natural systems in which Hg(0) and Hg(II) co-exist and get in contact with each other.
Our study and others20,54,55,95 have already demonstrated that Hg0 is present across both sites (Section 3.2.3), which provides the necessary starting point for this dark abiotic MIF process to occur. The oxygen content of the site A aquifer was generally low and variable across the sampling campaigns and mean values of the wells ranged from <1–68% saturation (Table S3.4†). The oxygen content in the site B aquifer was higher (range: 51–100%), but regularly below saturation (Table S3.5†). There may have been areas within vadose zone and aquifer capillary fringe of site B in the past in which intermittently wetted, and more anaerobic conditions prevailed based on the historically variable groundwater depth (Section S3†). Thus, the dark abiotic equilibrium isotope fractionation between Hg(0) and Hg(II) may be responsible for the more negative Δ199Hg values observed in the liquid-phase samples and the significant positive relationship (p < 0.001) between Δ199Hg values and THg concentrations in groundwater at site B (Fig. 9).
While we were able to distinguish industrial contamination Hg (less negative δ202Hg) from background Hg (more negative δ202Hg) using Hg stable isotopes in general terms, a general assessment such as this can also be accomplished using THg concentrations. Hg stable isotope MDF end member mixing models are difficult to employ as the isotopic signature of original Hg source material is usually not known and that of Hg ore minerals not well constrained. In situ transformation processes can also impart MDF. Thus, we suggest using Hg stable isotopes to understand these in situ biogeochemical processes driving MDF (and MIF) to be the more impactful application of the method than Hg source tracing.
The speciation analyses (PTD and SEP) and Hg stable isotope analyses of SEP extracts were beneficial complementary tools in extending these interpretations. Combining PTD analyses with Hg stable isotopes provided evidence that layers of Hg enrichment could not be primarily a result of reduction of Hg2+ species exchangeable by water (i.e., HgCl2) to Hg0. The more negative δ202Hg values observed in these enriched layers (in SCB1) were likely a result of preferential sorption of lighter isotopes of Hg2+ from the liquid-phase to the solid-phase rather than a fractionation caused by equilibrium isotope exchange between Hg0 and Hg2+. Moreover, performing Hg stable isotope analyses of data on SEP extracts also exhibited some unique information, for instance, a progressively more negative δ202Hg shift in SEP stable isotope analyses from F1 to F2 to F3 to F4 suggests multiple speciation changes as light isotopes are favoured in products.
It is well established that speciation analyses such as PTD and SEP have both strengths and weaknesses; our comprehensive assessment of all the methods used in this study confirmed many of these advantages and disadvantages. PTD is an effective tool for identifying the presence of Hg0 and estimating Hg0 concentrations (peak-fitting) in solid-phase samples. The major limitation of this method remains the identification of specific Hg2+ species. While SEP analyses can provide additional information on some Hg species, fractions, or pools of Hg, many limitations or artefacts are matrix related, which our data also confirm. This was compounded in our study by the original contamination being HgCl2 and the presence of Hg0 species, both of which are not extractable in a single SEP fraction (the former as evidenced by the continuous release of Hg exchangeable by water, i.e., HgCl2, in repeated water extracts of the same sample). It is likely there will be site-to-site variability in the SEP fraction some species are released in. Thus, it is difficult to recommend the use of SEP for general Hg geochemical site assessments when considered on its own without a specific methodological objective in mind.
The application of Hg isotopes in Hg geochemistry is still relatively new and many processes that might occur in the natural environment have not been examined in laboratory conditions to determine fractionation factors. This puts a limit on how much we can presently interpret Hg isotope signatures of environmental samples. It is critical that laboratory examination of fractionation factors for MDF and MIF of known and potential biogeochemical processes continue to be pursed and then examined via holistic field studies such as this. Equally as important is the need to continue to assess these processes in field-based studies as we have done here to determine if they are indeed relevant (do occur) and can be identified under environmentally relevant conditions. We are still only beginning to explore the potential of using Hg stable isotope signatures to provide novel insights into Hg biogeochemistry.
Footnotes |
† Electronic supplementary information (ESI) available: Raw data from all analyses. If readers require any additional information or data, please contact the corresponding authors. Reference to the supplement is made throughout the article using the prefix “S” before sections, figures, and tables. See DOI: 10.1039/d1em00368b |
‡ Authors contributed equally. |
§ Data do not include −4.75 m sample at the top of sediment layer (δ202Hg: −1.01‰) with much lower THg (0.37 mg kg−1). This low THg, negative δ202Hg outlier sample is likely associated with heterogeneously distributed Hg. |
This journal is © The Royal Society of Chemistry 2022 |