Issue 11, 2016

pulSED: pulsed sonoelectrodeposition of fractal nanoplatinum for enhancing amperometric biosensor performance

Abstract

For the first time, we combine pulsed electrodeposition with out-of-phase pulsed sonication for controlled synthesis of fractal nanoplatinum structures as the transducer layer in electrochemical sensing. We develop and test this technique, called bimodal pulsed sonoelectrodeposition (pulSED), as a simple approach for creating highly conductive transducer nanometals for use in sensing and biosensing. We first compared the efficiency of pulSED nanoplatinum to other pulsed electrodeposition techniques, and then explored the effect of duty cycle and plating time on electroactive surface area and nanoparticle size/morphology. The developed pulSED nanoplatinum displayed fractal features with a relatively homogenous size distribution (26.31 ± 1.3 nm) and extremely high electroactive surface (0.28 ± 0.04 cm2) relative to other electroplating techniques (up to one order of magnitude higher). A high duty cycle (900 mHz) promotes formation of stable nanostructures (including fractal nanostructures) and reduces amorphous structure formation due to bubble cavitation and enhanced mass transport of metal ions to the electrode surface. To demonstrate the applicability of the pulSED technique, non-enzymatic and enzymatic sensors were developed for measuring hydrogen peroxide and glucose. The sensitivity for non-enzymatic peroxide sensing (3335 ± 305 μA cm−2 mM−1), non-enzymatic glucose sensing (73 ± 14 μA cm−2 mM−1) and enzymatic glucose biosensing (155 ± 25 μA cm−2 mM−1) was higher than, or similar to, other nanomaterial-mediated amperometric sensors reported in the literature. The pulSED technique is a one pot method for tunable synthesis of nanometal structures as a transducer layer in electrochemical sensing and biosensing that requires no precursors or capping agents, and can be carried out at room temperature with inexpensive hardware.

Graphical abstract: pulSED: pulsed sonoelectrodeposition of fractal nanoplatinum for enhancing amperometric biosensor performance

Supplementary files

Article information

Article type
Paper
Submitted
10 Jan 2016
Accepted
20 Apr 2016
First published
20 Apr 2016

Analyst, 2016,141, 3367-3378

pulSED: pulsed sonoelectrodeposition of fractal nanoplatinum for enhancing amperometric biosensor performance

M. Taguchi, N. Schwalb, Y. Rong, D. C. Vanegas, N. Garland, M. Tan, H. Yamaguchi, J. C. Claussen and E. S. McLamore, Analyst, 2016, 141, 3367 DOI: 10.1039/C6AN00069J

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements