Issue 43, 2022

Quantification of docusate antimicrobial finishing after simulated landfill degradation via tandem mass spectrometry and QuEChERS extraction

Abstract

An analytical method for the detection and quantification of silver docusate antimicrobial finishing in soil was developed through a combination of the QuEChERS extraction method and tandem mass spectrometry (MS/MS) quantification with isotopically labeled internal standard. First, the calibration system was established in the matrix where QuEChERS extraction removed docusate from soil. The addition of an isotopically labeled internal standard reduces ionization suppression due to instrumental fluctuation and run-to-run deviation. After establishing the calibration system, this quantification method was validated according to a guideline from the U.S. Food and Drug Administration. A series of variables for quantification were validated including coefficient of determination (R2 = 0.989 ± 0.002), percent error (% error = 3 ± 4%), coefficient of variation (% CV = 6 ± 1%), limit of detection (LOD = 8 ± 2 ng mL−1), lower limit of quantification (LLOQ = 27 ± 5 ng mL−1), recovery and matrix effect (matrix effect = 0.944 ± 0.026). Those parameters were obtained from the inter- and intra-day measurements for both calibration and the quality control standards. Later, samples extracted from a simulated landfill degradation of cotton fabrics applied with sliver docusate antimicrobial finishing were measured. It was observed that the concentration measured (51 ± 5 ng mL−1 or 252 ± 25 ng g−1) fell into the ranges defined by the method development with good precision (% CV = 4 ± 1%). Results from this study could further the understanding of textile landfill degradation and facilitate further study regarding docusate contamination in soil.

Graphical abstract: Quantification of docusate antimicrobial finishing after simulated landfill degradation via tandem mass spectrometry and QuEChERS extraction

Article information

Article type
Paper
Submitted
18 Jul 2022
Accepted
10 Oct 2022
First published
12 Oct 2022

Anal. Methods, 2022,14, 4338-4343

Quantification of docusate antimicrobial finishing after simulated landfill degradation via tandem mass spectrometry and QuEChERS extraction

X. Sui, C. Feng, M. Ankeny and N. R. Vinueza, Anal. Methods, 2022, 14, 4338 DOI: 10.1039/D2AY01153K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements