V.
Corradini
*a,
A.
Candini‡
a,
D.
Klar
b,
R.
Biagi
ac,
V.
De Renzi
ac,
A.
Lodi Rizzini
acd,
N.
Cavani
ac,
U.
del Pennino
ac,
S.
Klyatskaya
e,
M.
Ruben
ef,
E.
Velez-Fort
g,
K.
Kummer
g,
N. B.
Brookes
g,
P.
Gargiani
h,
H.
Wende
b and
M.
Affronte
ac
aCentro S3, Istituto Nanoscienze – CNR, via G. Campi 213/A, 41125 Modena, Italy. E-mail: valdis.corradini@nano.cnr.it
bFaculty of Physics and Center for Nanointegration Duisburg-Essen (CENIDE), University of Duisburg-Essen, Lotharstraße 1, D-47048 Duisburg, Germany
cDipartimento di Scienze Fisiche, Matematiche e Informatiche, Università di Modena e Reggio Emilia, via G. Campi 213/A, 41125 Modena, Italy
dCNR-IOM, Laboratorio TASC, Area Science Park, S.S. 14, km 163.5, 34012 Basovizza (Trieste), Italy
eInstitute of Nanotechnology, Karlsruhe Institute of Technology (KIT), D-76344 Eggenstein-Leopoldshafen, Germany
fInstitut de Physique et Chimie des Materiaux de Strasbourg, UMR 7504 UdS-CNRS, 67034 Strasbourg Cedex 2, France
gEuropean Synchrotron Radiation Facility (ESRF), Avenue des Martyrs 71, 38043 Grenoble, France
hALBA Synchrotron Light Source, E-08290 Barcelona, Spain
First published on 15th November 2017
Lanthanides (Ln) bis-phthalocyanine (Pc), the so-called LnPc2double decker, are a promising class of molecules with a well-defined magnetic anisotropy. In this work, we investigate the magnetic properties of LnPc2 molecules UHV-deposited on a graphene/Ni(111) substrate and how they modify when an Au layer is intercalated between Ni and graphene. X-ray absorption spectroscopy (XAS), and linear and magnetic circular dichroism (XLD and XMCD) were used to characterize the systems and probe the magnetic coupling between LnPc2 molecules and the Ni substrate through graphene, both gold-intercalated and not. Two types of LnPc2 molecules (Ln = Tb, Er) with a different magnetic anisotropy (easy-axis for Tb, easy-plane for Er) were considered. XMCD shows an antiferromagnetic coupling between Ln and Ni(111) even in the presence of the graphene interlayer. Au intercalation causes the vanishing of the interaction between Tb and Ni(111). In contrast, in the case of ErPc2, we found that the gold intercalation does not perturb the magnetic coupling. These results, combined with the magnetic anisotropy of the systems, suggest the possible importance of the magnetic dipolar field contribution for determining the magnetic behaviour.
Along this line, the class of lanthanides (Ln) bis-phthalocyanine (Pc), the so-called LnPc2double decker, have received considerable attention, since they present the same versatility as the transition metal phthalocyanines and porphyrins, but behave as single molecule magnets (SMMs), retaining their magnetization below a certain blocking temperature.10,11 This magnetic nature derives from their morphology and electronic configuration: the magnetization of the f-shell Ln ions exhibits a well-defined magnetic anisotropy, as a consequence of the ligand field created by the two Pcs between which the magnetic ions are sandwiched. Furthermore, the neutral derivative [LnPc2]0 possesses one unpaired electron that is delocalized in the phthalocyanines, making the molecules suitable for ligand-mediated interactions with the substrates.12
TbPc2 couples antiferromagnetically when deposited on a magnetic layer and behaves as an independent magnetic unit, given that its magnetization depends critically on the orientation of the molecule easy axis as well as on the interplay of ligand mediated super-exchange interaction with the substrate and the applied magnetic field.7 In recent works, we have demonstrated that super-exchange interaction can couple the magnetic moment of the Ln to Ni substrates thanks to a partial overlap of the d-orbitals of the Ln (in turn, mediating the polarization of the inner f-shell electrons) with those of the Pc.13
Super-exchange interactions between a magnetic substrate and 3d single atoms/clusters,14 transition metal phthalocyanines and porphyrins12,15–17 and LnPc2 SMMs18 have been observed also when a graphene interlayer is present. In recent years, graphene has been widely studied for applications in the field of spin transport and spintronic devices19 due to its properties such as high in-plane charge carrier mobility,20 weak spin–orbit interaction and the capability to passivate metal (and magnetic) surfaces through weak van der Waals interactions with the surface.21,22 It is therefore extremely interesting to investigate in detail the role of a graphene layer in mediating the coupling between a magnetic substrate and the molecular moieties. We have recently shown, for the case of the TbPc2 molecules, that a graphene layer directly grown on Ni still allows super-exchange coupling through a relay-like mechanism mediated by the electron spin delocalized in the Pc ligands.18
In the present work, we pursue this issue, investigating the presence or absence of magnetic coupling between a molecular probe and a graphene/Ni(111) substrate when an Au layer is intercalated between Ni and graphene. In this system, Au acts as a further spacer, increasing the distance between the ferromagnetic substrate and the molecules, and also changes the characteristics of the graphene layer. The most important effect is the decoupling of graphene from the Ni substrate, thus almost restoring its free-standing properties.23 Moreover, the gold layer induces, through spin–orbit interaction, significant spin splitting of the energy bands of graphene.24
For our purposes we focus, as molecular probes, on two LnPc2 derivatives bearing a strong – but different – magnetic anisotropy.25 TbPc2 has an L = 3, S = 3, J = 6 ground state and the ligand field leads to a huge uniaxial anisotropy, leaving the mJ = ±6 doublet to behave as an Ising spin with the easy axis perpendicular to the planes of the two phthalocyanines. ErPc2 has an L = 6 S = 3/2 J = 15/2 ground state and the ligand field induces an in-plane anisotropy, leaving the mJ = ±1/2 as the ground doublet.
After describing the preparation and characterization of the systems, we focus on the results of low temperature XMCD investigations. For the sake of completeness, we compare the molecule behaviour on graphene/Au/Ni with that observed when molecules are deposited directly on bare Ni(111) and on graphene/Ni(111), as reported in previous works.13,18
The X-ray Absorption Spectroscopy (XAS) experiments were carried out at the BOREAS beamline30 of the ALBA Synchrotron Radiation Facility (Spain) and at the ID32 beamline31 of the European Synchrotron Radiation Facility (ESRF) in Grenoble (France). Once introduced into the experimental chamber, the ex situ prepared samples were annealed at 300 °C for 5 min to restore the SLG/Ni(111) and SLG/Au/Ni(111) surfaces. ∼0.3 monolayer of LnPc2 molecules (Ln = Tb, Er) was evaporated from well-outgassed powder evaporators, at a temperature of 420 °C and at a base pressure of 1.0 × 10−9 mbar. The evaporation rate and the film thickness were monitored through a calibrated quartz microbalance. The coverage was also cross-checked in situ by XAS, using a reference sample with coverage determined by XPS. Furthermore, the chemical integrity and the coverage of the deposited LnPc2 molecules were verified ex post by XPS [see ref. 18] and by STM investigations (see the ESI†).
Circularly and linearly polarized XAS measurements at the Ln-M4,5 and N-K absorption edges were performed in total electron yield mode. For all measurements, the base pressure in the measurement chamber was 1.0 × 10−10 mbar and the base temperature was 2 K (BOREAS) and 8 K (ID32). XMCD measurements were taken with the photon beam and the external magnetic field B (always collinear) applied either at normal or grazing incidence, i.e. at an angle θ equal to 0° and 70°, respectively, relative to the surface normal (Fig. 1d). To avoid beam-induced molecule degradation, we minimized both the power and energy densities, respectively, by defocusing the beam and regularly changing the spot position on the sample. Furthermore, we carefully monitored the XAS spectra lineshape, finding no indication of damage.
The dichroic signal (XMCD) is a measure of the magnetization component along the impinging beam direction of the particular chemical species. It is expressed in percentage, i.e. by taking the difference between the two XAS spectra obtained with different X-ray polarizations (σ↑↓ − σ↑↑) and dividing it by the edge height of the absorption spectrum obtained by the average of the two polarizations. Note that by defining the value of the dichroic signal in this way, it does not depend on molecular coverage.
In this work, we focus our attention on the low magnetic field behaviour of the LnPc2 species: in order to obtain a suitable signal to noise ratio, XMCD data are obtained by integrating over several XAS acquisitions, taken at the two opposite polarizations.
The full-range magnetization curves M(B) (from −5 T to 5 T and the way back), taken for both Ln ions deposited on the bare Ni(111) and on SLG/Au/Ni(111) substrates (Fig. 4 and Fig. S6†), were obtained by plotting the maximum value of the XMCD signal as a function of the external applied magnetic field under isothermal conditions. Measurements in the low-field region [−0.5, 0.5 T] were taken in this specific range after having applied the procedure for minimizing the residual field of the magnet. In order to obtain a satisfactory S/N ratio, for the lowest field values we had to average several tens of spectra for each polarization. This implied a very long time for the acquisition in this field range, allowing us to collect only one way, i.e. from −0.5 to 0.5 T. The time required for the whole XMCD measurements in this range was about ten hours.
Conversely, in the case of the SLG/Ni(111) substrate (Fig. 4e and f) and for Ni(111) clean (Fig. 4a and b) Ni magnetization curves were measured in a faster manner, acquiring, for each field, the XAS intensities at the pre-edge (P) and at the energy corresponding to the XMCD maximum (E), and evaluating the quantity:
M = [(Eσ↑↓ − Pσ↑↓) − (Eσ↑↑ − Pσ↑↑)]/1/2[(Eσ↑↓ − Pσ↑↓) + (Eσ↑↑ − Pσ↑↑)] |
Typical XAS and X-ray Magnetic Circular Dichroic (XMCD) spectra are shown in Fig. 2 and 3. The lineshape of both XAS and XMCD spectra at the Ln-M5 edge for the two LnPc2 molecules deposited on SLG/Au/Ni(111) (Fig. 2c) is very similar to that of the corresponding ones obtained with the derivatives deposited on SLG/Ni(111)18 (Fig. 2b) or directly on Ni(111)13 (Fig. 2a) and does not change with temperature and magnetic field intensity (Fig. S4†). This allows us to assume the integrity of the adsorbed molecules on all the considered substrates.
Fig. 2 Comparison of the XAS spectra at the Ln M5 edge for the LnPc2 on SLG/Au/Ni(111) (panel c) with the corresponding ones obtained on bare Ni(111) (a) and on SLG/Ni(111) (b). The data relative to the LnPc2 molecules deposited on bare Ni(111)13 and for the TbPc2 on SLG/Ni(111)18 are taken from our previous works and shown for comparison. The shape of the XMCD spectra (d) is the same for the three substrates. Measurement conditions: H = 5 T, θ = 70°. The temperature is T = 8 K for panels a and b and T = 2 K for panel c. |
The different orientation of the molecular easy-axis allowed us to investigate the role of anisotropy in the mechanism determining the molecule–substrate magnetic coupling. To this end, the magnetic coupling between the Ln ions and the Ni substrate was studied by taking the magnetization curves M(B), i.e. by measuring the maximum value of the XMCD signal as a function of the external applied magnetic field under isothermal conditions. The full-range magnetization curves (−5 T to 5 T), taken for both Ln ions and for all three possible substrates (i.e. bare Ni(111), SLG/Ni(111) and SLG/Au/Ni(111)) are shown in ESI Fig. S6.†
Here, we focus our attention on the low-field region (−1 T, 1 T), where the Zeeman interaction is reduced and the effect of coupling is expected to become predominant. In Fig. 4, the M(B) curves at the Ln-M5 edge for all three substrates are reported, along with the corresponding simulated curves (see the Discussion). These are compared to the magnetization curves of the corresponding substrates taken at the Ni-L3 edge: panel (a) reports the M(B) curve measured, at θ = 70°, on the Ni(111) single crystal used for the deposition of the TbPc2 molecule, while the substrate used during the experiments with the ErPc2 molecule is shown in panel (b). The Ni M(B) curves slightly differ from one Ni sample to the other. At variance, we verified that they are not affected by the surface preparation, i.e. bare Ni, SLG/Ni or SLG/Au/Ni all show identical M(B) curves.
Fig. 4 Comparison of the magnetization curves at the Ni-L3 (panels a and b) and at the Ln-M4,5 edges (Tb: left panels and Er: right panels) at θ = 70°. The hystereses of the two Ni are different because the measurements on TbPc2 and ErPc2 were performed on two different Ni(111) single crystals. The experimental curves (symbols in panels c–h) are in excellent agreement with the simulated ones (red lines) as described in the text. The Ln data are a low-field magnification of Fig. S6.† Data in panels c, d and e are taken from ref. 13 and 18, respectively. In bold we indicate the values of the exchange strength (λ), expressed in Tesla. The temperature is 8 K for all the measurements apart from panel g, measured at T = 2 K. |
The Ni and Tb M(B) measured at normal incidence for the TbPc2 deposited on bare Ni, on SLG/Ni(111) and on SLG/Au/Ni(111) are presented in Fig. S5 (see ESI†). We did not show the magnetization for the ErPc2 since the dichroic signal, at θ = 0°, is almost zero.
When the molecules are directly deposited on Ni (panels c and d) we observe that, for small fields, the lanthanide magnetizations are opposite to B. On increasing further the field magnitude, a sudden change of the slope sign is observed in correspondence with the field at which the Ni magnetization starts to saturate. Finally, the Ln magnetizations become parallel to the external magnetic field and to the magnetization of the Ni substrate for large enough values of B. These features demonstrate the antiferromagnetic character of the coupling of the lanthanide atom to the Ni substrate, in agreement with previously reported findings.7,13
When the LnPc2 molecules are deposited on SLG/Ni (panels e and f), although a reversed sign of the magnetization can no longer be measured, a clear change of the slope of the M(B) curves at low fields is still observed. This behaviour shows that, for both molecules, antiferromagnetic coupling with the substrate is still present, although reduced by the presence of the graphene layer. This finding, which has already been reported in the case of TbPc2,18 is here proved to be valid also in the case of ErPc2.
We now focus our attention on the effects of Au intercalation between graphene and Ni. Extracting reliable XMCD intensity values at very low field, where the dichroic signal is extremely small, is actually not trivial. To this end, we developed a fitting procedure which is illustrated in detail in the ESI.† The results of this analysis are shown in panels g and h of Fig. 4, where the main experimental finding of the present work is reported, i.e. the low-field magnetization curves for Tb and Er adsorbed on gold-intercalated SLG. It is observed that, while in the case of TbPc2 the gold intercalation wipes out all kinds of coupling, for ErPc2 the antiferromagnetic coupling between the metal ion magnetic moment and the Ni substrate persists even when they are separated by the gold-intercalated graphene.
In all cases, Beff is assumed to be proportional to the Ni magnetization; therefore Beff is defined as Beff = λMNi, where MNi is the Ni(111) magnetization, as measured experimentally by XMCD and normalized to its saturation value, and λ is the parameter related to the strength of the coupling (expressed in Tesla). The curves in Fig. 4 are calculated using JTb = 6, JEr = ½, temperature T = 8 K and neglecting any anisotropy.
While the correct fit of the full magnetization curves would require the complete theoretical model used in previous works,7,13,18 for the low magnetic field region which is here of interest, our measured magnetization curves are essentially linear with respect to B and the agreement with the simulated BJ function is already satisfactory. Thus, this simple model allows us to evaluate the strength of the magnetic coupling. In particular, focusing on the ErPc2 behaviour, we found that the estimated strength of the antiferromagnetic coupling is λ = −0.25 ± 0.02 T in the case of the bare Ni substrate, λ = −0.08 ± 0.02 T in the case of the SLG/Ni substrate and −0.08 ± 0.02 T when ErPc2 molecules are deposited on Au-intercalated SLG on Ni(111).
Instead, in the case of the TbPc2 we found that λ = −0.9 ± 0.02 T when TbPc2 molecules are deposited directly on Ni, −0.1 ± 0.02 T on the SLG/Ni substrate and zero for SLG/Au/Ni(111). Here the minus sign accounts for the antiferromagnetic nature of the coupling.
We should here mention that, at variance with measurements performed at grazing incidence (θ = 70°), the TbPc2/SLG/Ni M(B) measurements at θ = 0° (see the ESI†) does not show any signature of molecule/substrate magnetic coupling. This can be explained considering the angular dependence of the nickel magnetization curves: while at θ = 70° Ni magnetization saturates already at ∼0.2 T, at θ = 0° saturation occurs only for magnetic field values >0.5 T. Therefore, at θ = 0° and for fields smaller than 0.5 T, which is the relevant case here, Ni magnetization is significantly smaller than its saturation value, thus substantially hampering the experimental observation of the possible magnetic coupling signature.
The effect of introducing a graphene layer between the molecule and the ferromagnetic Ni(111) substrate has already been discussed in detail in our recent work in the case of TbPc2.18 Graphene directly grown on Ni still allows magnetic coupling, although a substantial weakening is observed. The intercalation of an Au layer makes the coupling between the Tb magnetic moment and the Ni substrate no more detectable within our experimental accuracy.
The situation is quite different in the case of ErPc2, where the gold intercalation has essentially no effect on the coupling. It is worth remarking here the different relative orientation of the magnetic anisotropy of the two Ln ions (easy-axis for Tb vs. easy-plane for Er) and the Ni substrate magnetization. Indeed, the critical role of the alignment between the molecular easy axis and the substrate magnetization has already been demonstrated in the case of TbPc2 on Ni thin films.7
Starting from these considerations, we can envisage a qualitative explanation for the observed behaviour, which takes into account the dipolar stray field coming from the magnetization of the nickel substrate. A precise evaluation of the intensity of the substrate-induced stray field would require a detailed knowledge of closure-domain distribution at the surface, which is indeed a demanding issue. Nonetheless, the order of magnitude of the magnetic field intensity at the nickel surface, produced by the uniform magnetization of the whole (macroscopic) crystal, can be estimated calculating the field produced by a uniform collection of magnetic dipoles, each of which is associated with a single atom of the Ni sample (see details of the calculations in the ESI†).
The magnetic field components perpendicular (Bz) and parallel (Bx) to the surface of a disc-shaped sample of radius R and thickness D, calculated along its axis, at a distance d from the surface, are given by:
(1) |
(2) |
These results show that the strength of the dipolar field at the surface depends critically on the aspect ratio D/R and is therefore non-negligible in the case (as ours) of macroscopically thick samples. Moreover and most importantly, they demonstrate that the intensity of the dipolar magnetic field does not depend on the distance d from the nickel surface, as long as d ≪ D (i.e. d is in the nm range, while D is in the mm range).
Upon inserting the values of the Bohr magneton μB, the Nickel unit cell volume Vcell and the sample dimensions D and R in eqn (1) and (2), we obtain that the magnitude of both components is of the order of tens of mT (Bx = −50 mT and Bz = +35 mT), i.e. the same as the coupling strength previously experimentally evaluated.
It is important here to note that the component parallel to the surface is more intense than the orthogonal one. Furthermore, the first is negative, i.e. it would provide an anti-ferromagnetic coupling (with respect to the Ni magnetization) with a magnetic dipole located at the surface, whereas the latter is positive, i.e. it would induce a ferromagnetic coupling. The dipolar field felt by the adsorbed molecules is therefore not negligible and essentially the same independently from the layers (SLG, Au) under them. In contrast, the (super-) exchange interaction, being mediated by wave-functions, strongly depends on distance and/or interposed layer. In previous works we proved that SLG was able to keep a significant exchange coupling between Ni and the lanthanide atom. This is true in particular for Tb, which also shows the strongest coupling among the studied lanthanide species. The vanishing of the coupling when gold is intercalated suggests the vanishing of the exchange interaction responsible for the coupling.
So, why does Er keep the same coupling as without gold? Possibly, the coupling of the Er atoms is mainly due to the dipolar field already for the case of the SLG/Ni(111) substrate, and this would come from its in-plane anisotropy, favouring the coupling with the in-plane dipolar field. The invariance of the coupling strength with or without the gold layer is a strong clue in this direction. Of course, a similar interaction is present also for Tb, but the coupling between the in-plane dipolar field and the easy-axis anisotropy, orthogonal to it, makes the coupling too weak to be detected.
In conclusion, we have studied the magnetic coupling between two types of LnPc2 molecules, characterized by different magnetic anisotropies, and a Ni(111) magnetic substrate through an Au-intercalated SLG layer. In the case of Tb, the antiferromagnetic signal – which can be attributed to (super)-exchange coupling, vanishes upon Au intercalation. This effect can be attributed to both the increased distance between the molecular species and the magnetic substrate and to the same mechanisms leading to the intercalation-induced electronic decoupling of the graphene layer from the Ni substrate. A full understanding of the mechanisms underlying the observed vanishing would require a detailed theoretical modelling of the system, which implies considerable computational efforts and is clearly beyond the scope of this work.
In the case of Er on the other hand, the small antiferromagnetic signal does not seem to be affected by intercalation, which can be rationalized by taking into account a relevant contribution of the substrate magnetic dipolar field. Our work therefore suggests the possible importance of the magnetic dipolar field for determining the behaviour of hybrid metal–organic magnetic interfaces, especially when combined with the magnetic anisotropy of the systems.
Footnotes |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/c7nr06610d |
‡ Present address: Istituto di Sintesi Organica e Fotoreattività (ISOF), Consiglio Nazionale delle Ricerche (CNR), Via Gobetti 101, 40129 Bologna, Italy. |
This journal is © The Royal Society of Chemistry 2018 |