Safe disposal of nuclear waste is essential to ensure the sustainability of nuclear energy. This is especially true for the volatile radionuclide iodine-129 due to its long half-life (15.7 Ma) and high mobility in most disposal environments. The dissolution behaviour of lead vanadium iodoapatite (Pb5(VO4)3I) synthesized to evaluate its possible use for immobilizing iodine-129 was investigated to understand the mechanism by which iodide is released. Experiments using a semi-dynamic method were carried out in cap-sealed Teflon vessels at a constant temperature 90 ± 0.5 °C with a fixed sample surface area-to-solution volume ratio of 16 m−1. The leachates were analyzed using inductively coupled plasma mass spectrometry (ICP-MS) and the leached surfaces were examined by X-ray diffraction (XRD), scanning electron microscopy (SEM) and infrared spectroscopy (IR). The results show that lead and vanadium dissolved congruently at a constant rate, while the iodine was initially released at a significantly higher rate than suggested by its stoichiometry with respect to lead and vanadium. The iodine-to-lead molar ratio in the solution gradually decreased over time, but iodine release remained superstoichiometric. The results suggest the release of iodide occurs by an ion-exchange process that is faster than the dissolution rate of the Pb–V–O framework. Analysis of the leached samples shows that the spectroscopic signature of OH groups in the leached samples is consistent with an ion exchange mechanism.
Among the waste forms being evaluated, single phase ceramic iodoapatite Pb5(VO4)3I has been proposed as a waste form for iodine-129,6–18 and is simpler than multiphase waste forms5 in terms of phase complexity, microstructure, and composition, which are a great challenge to evaluate their chemical durability because of the complications from their complexity. In the iodoapatite structure, Pb cations occupy two crystallographic sites with 8 and 9 coordination numbers and V forms tetrahedra with oxygen. Together, VO4 and Pb sites form a more covalently bonded framework structure while the iodide anions, at the channel site in the crystal structure, are more ionically bonded to the cations due to a smaller ionic potential (charge to radius ratio) than the lead ion.19
The results of previous durability tests with iodoapatite vary significantly.9,17,20–22 For instance, a durability study was conducted in deionized water at 90 °C for iodoapatite (Pb10(VO4)4.8(PO4)1.2I2) synthesized with a hot press method at 25 MPa and 700 °C using a flow through method.20 The initial iodine leaching rate was high but gradually decreased to a rate of 2.5 × 10−3 g m−2 d−1 after 2 weeks in a 38 day experiment. In another experiment, an iodoapatite sample with a composition Pb10(VO4)4.8(PO4)1.2I2 synthesized at similar conditions9 was studied using a static test method.23 The initial release rate in pure water was 2.4 × 10−3 g m−2 d−1 at 90 °C,9 which makes iodoapatite a promising candidate as an iodine waste form. The low release rate was speculated to be caused by surface layers or secondary phases. Recently, a durability study using static leaching experiment was carried out to examine iodoapatite Pb5(VO4)3I that was synthesized using a dry mechanochemical process at 400 °C.21 The iodine release rate in pure water at 25 °C and surface area-to-solution volume ratio (S/V) of 1.0 m−1 was 2.6 × 10−1 g m−2 d−1 on the first day and reduced to 8.8 × 10−3 g m−2 d−1 after 56 days of experiments, which is still much higher than the value of 1.7 × 10−4 g m−2 d−1 measured by Guy et al. in a similar static leaching experiment.9 The result leads to the question whether or not sufficient protecting layers were formed in the leaching experiment. More recently, an iodate (IO3−) variation of iodoapatite, Ca10(PO4)6(IO3)0.92(OH)1.08, was proposed to incorporate iodine into hydroxyapatite by substituting OH− groups with IO3− in hydroxyapatite.13,17 The sample was tested using static leaching experiment at 50 °C in deionized water,24 which gave an initial release rate of iodine 2 × 10−2 g m−2 d−1 and a residual rate of 7 × 10−5 g m−2 d−1, with a S/V ratio of 800 m−1 and 8000 m−1 respectively. As seen from the above experimental results, reported iodine leaching rates vary by 4 orders of magnitude, from 10−1 and 10−5 g m−2 d−1, largely due to the differences in the sample compositions, test methods, test parameters, and sample synthesis methods. Therefore, citing an iodine release rate from an experiment should always include details of the sample composition, test method along with test conditions, and how the rate is calculated. For iodoapatite with different iodine species, e.g., iodide vs. iodate, the leaching kinetics is expected to be different. For iodoapatite with similar compositions, it is challenging to integrate those experimentally measured rates for the understanding of the iodine leaching mechanism because of different test conditions and test methods. Therefore, it is necessary to conduct a systematic study that provides mechanistic insight of the waste form durability and the radionuclide release behaviour.
During a static leaching experiment, dissolved species accumulate in the solution. An increase of the chemical potential of the dissolved species in solution leads to the decrease of free energy driving force (chemical affinity), resulting in a reduced dissolution rate (solution feedback) if the dissolution is solubility-controlled. The rate at which species build up in solution during a static leaching experiment is dependent on the S/V ratio. For dynamic leaching experiments, the build-up is dependent on flow rate and surface area of the sample in a continuous flow through experiment, and on the S/V ratio and exchange interval in a semi-dynamic leaching experiment. Therefore, it is not appropriate to directly compare the rates discussed above that were measured using different test methods or simply to infer the leaching mechanism based on such comparisons. Secondary phase formation also affects leaching rate that can be misinterpreted as incongruent release of iodine.17,21 It was speculated that ion exchange affects the iodine release,17,21 which, however, has not been quantified. A spectroscopic study of iodoapatite Pb5(VO4)3I surfaces leached at pH 11 in a KOH/KHCO3 buffered solution at 90 °C for up to 8 weeks10 showed a CO32− Raman peak around 1058 cm−1 and OH− peak around 3538 cm−1, suggesting that the iodide I− is replaced by OH− and CO32− through an ion exchange process. However, there is a strong pH dependence of dissolution of apatite at acidic and basic conditions,9,25–28 and most of the leaching experiments were conducted with deionized water at near-neutral pH where the dissolution rate is low and not sensitive to pH changes. Thus, it is necessary to investigate whether the iodide exchanges with OH− in deionized water and to what extent the ion exchange affects iodide release at near-neutral pH when the OH− concentration is low.
The focus of this study is to understand the dissolution mechanism of iodoapatite pellets based on the measured solution concentrations, model fitting, and surface microscopic and spectroscopic characterizations. Iodoapatite is a single phase material in which the iodine is stoichiometrically incorporated in a crystallographic site. Our hypothesis is that, due to different bonding environments in the structure (i.e., the more ionic bonding of the iodide and more covalent bonding of the framework Pb, V, and O), the weakly ionically bonded iodide ion can be preferentially released by ion exchange with OH− while the framework structure dissolves. A semi-dynamic test method was used to distinguish between dissolution-controlled and diffusion-controlled release processes. The results provide an improved understanding of how the iodine release is controlled by different processes that include dissolution and diffusion, the latter involves ion exchange of iodide and hydroxide.
The experiments were conducted in cap-sealed Teflon vessels (Savillex) in a digitally controlled oven at a constant temperature of 90 ± 0.5 °C using deionized water as the leachant. The apatite pellet was placed on a mesh stand in a Teflon vessel (30 mL), which was filled with deionized water to provide an S/V ratio of 16 m−1. The S/V ratio is considered to remain constant during the experiment as the leached fraction of the sample is very small (∼2 × 10−5). The leachant replacement intervals were 2, 5, and 17 hours for the first three intervals and 24 hours thereafter based on the test protocol.29 Due to large uncertainty of the data, the first three data points (first day) are not used for analysis and were excluded from the cumulative concentration. The vessels were weighed before and after each interval to monitor the solution weight loss. The loss of weight was mainly due to the cap seal of the Teflon vessel. Tests were performed on tightening the cap. All the experiments had a solution loss within 1% of the initial solution mass. In addition, to check if there are any deposits on the wall of the vessels, acid strip tests were applied to the vessels upon the termination of the leaching experiments. The elemental analysis on the strip solutions confirmed the sorption of leached elements on vessel is negligible.
The leachate was analysed with a PerkinElmer Elan 9000 Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) system. Internal standards cesium (Cs), manganese (Mn), and bismuth (Bi) were utilized in the analysis of iodine (I), vanadium (V), and lead (Pb) in leachate, respectively. Three standard solutions provided by Inorganic Ventures were used in ICP-MS calibration and analysis: (i) an iodine standard containing 1.001 ± 0.007 μg mL−1 iodide in H2O solution, (ii) a lead and vanadium standard containing 1.000 ± 0.007 μg mL−1 Pb and 1.000 ± 0.006 μg mL−1 V in 1% HNO3 solution respectively, and (iii) an internal standard containing 1.000 ± 0.009 μg mL−1 Cs, 1.000 ± 0.008 μg mL−1 Mn, and 1.000 ± 0.006 μg mL−1 Bi in 2% HNO3. For a typical leachate analysis, a 1 mL internal standard was added into a 14 mL leachate solution (often diluted). The overall error of measured concentration is estimated to be around 20% depending on the concentration, propagated from ICP-MS analysis, dilution of the leachate before analysis, geometric surface area estimation, leachant weight loss during experiment, and oven temperature control, among others.
Fig. 2 X-ray diffraction patterns of the surfaces of the pristine and water leached samples (Cu K-α1), along with the XRD pattern from ICDD database for comparison. |
Cumulative (t) = k1t1/2 + k2t + k3(1 − e−k4t) | (1) |
Comparing to the iodine release, the lead and vanadium releases are more or less linear with time (Fig. 3c and d), suggesting a constant dissolution controlled mechanism at a rate that is independent of time. Note that variations in the test intervals between 16 and 19 days in both tests are experimental artefacts that introduced a shift in the trends, but the data points before and after are linear with time.
The iodine release rate after three weeks of test is ∼0.18 mmol m−2 d−1 or 2.3 × 10−3 g m−2 d−1, calculated from the slope of Fig. 3a at 21 day, which is similar to the leaching rate (2.5 × 10−3 g m−2 d−1) reported in a flow through experiment with similar composition (Pb10(VO4)4.8(PO4)1.2I2).20 As both the experiments were conducted using dynamic protocols, the similar leaching behaviour is expected and the effect of slightly different compositions seems limited. In contrast, our measured rate is about one order of magnitude higher than the rate (2 × 10−4 g m−2 d−1) reported for iodoapatite (Pb10(VO4)4.8(PO4)1.2I2) using a static protocol after more than 1000 days of test.22 For static leaching experiment using a iodate apatite (Ca10(PO4)6(IO3)0.92(OH)1.08), the measured iodine release rate decreased about 2 orders of magnitude from initial release to residual release.17 Although the speciation of iodine and composition of iodoapatite have an important effect on iodine release rate, the dramatic differences in the rates for a given composition are primarily due to the different test methods (i.e., static tests give averaged cumulative rates and dynamic tests give instantaneous rates), various test parameters (e.g., S/V ratio, temperature), and how the rate is calculated (e.g., initial vs. residual). The results cannot be directly compared because the rates measured in static, dynamic, and semi-dynamic test methods have different meanings and depend on the dissolution mechanism.
In a dynamic test experiment, steady-state conditions may be attained between the flow rate and the dissolution rate for an affinity-controlled mechanism. The rate that is derived will depend on the steady-state solution composition under the particular test conditions and will represent an instantaneous rate. The rates measured in static tests are based on the accumulated concentrations of dissolved species and represent average rates over the test duration. In a static experiment, however, the solution feedback effect (affinity effect) increases over time, leading to the increased saturation with respect to the solid and reduced dissolution rate. The semi-dynamic tests described in this paper provide the average rates for a series of short intervals. The change in the rate over successive intervals gives insight into the dissolution mechanism. Constant rates measured over sequential intervals indicate a surface dissolution mechanism, whereas decreasing rates may indicate a diffusion-controlled mechanism. The rate measured for an interval will depend on the test conditions and time of the interval. The physical significances of the test results are different for diffusion-controlled processes, where time is the important variable. The semi-dynamic method was designed to study diffusion-controlled processes, for which static and dynamic methods are not effective. Therefore, the leaching rates measured by using different methods like static test cannot be directly compared with the results from flow through or semi-dynamic experiments.6,9,17,21,22 However, measurements of the leaching behaviour using different test protocols are necessary as they provide different aspects of the durability under different environmental conditions.
As suggested in the regression fitting of the Cote model (Fig. 3a), the enhanced iodide leaching with respect to lead and vanadium from the solid (Fig. 4) may originate from a diffusion-controlled process in which iodide (I−) in the solid is replaced by hydroxide (OH−) from the solution. Such a process is common for ions that are weakly bonded to a covalently bonded matrix structure such as in zeolites and clay minerals.33–37
The pH change of the leachate during leaching tests has been used as an indicator of ion exchange process between iodide or iodate in iodoapatite and hydroxide in solution in two previous experiments.17,22 The ion exchange reaction decreases the solution pH because the exchange reaction consumes hydroxide in the solution. Both of the experiments17,22 were performed using a static protocol with high surface to volume ratios (3000 m−1 and 8000 m−1 respectively). The accumulated ion exchange over the many days of the tests with limited iodoapatite dissolution under close to the saturated condition leads to a clear trend of pH decrease. However, a trend of pH change was not observed in our leaching tests because our leaching experiment is semi-dynamic and the leachate solutions are not accumulative. The average leachant (DI water) pH measured in our experiment was 5.3 ± 0.2 and the average leachate pH was 5.2 ± 0.2. A similar pH behaviour without a significant change of pH was also observed in a dynamic leaching test using a flow through protocol with a slight different composition (Ca10(PO4)6(IO3)0.92(OH)1.08).20 In fact, the measured pH values in our experiment are not reliable and don't reflect the pH in the Teflon vessel during the test because the solution is too dilute and was exposed to the air during the storage and pH measurement. Instead, thermodynamic calculations were performed to estimate pH change using MINTEQ and measured concentrations of the species in the solution. An average increase of pH by 0.15 was predicted at beginning of the test and 0.05 at near the end of the test.32 Due to the test protocol (semi-dynamic and daily replacement of the leachant) and a small surface to volume ratio 16 m−1, there were two processes in our leaching test: ion exchange, which causes the solution pH to decrease; and dissolution of the iodoapatite, which causes the pH to increase. As a result of the two processes and small progresses of the reactions within a day, the pH increases slightly but the change was too small to be detected. An increase of pH was observed in the initial test period of a static leaching experiment with similar the iodine release mechanism.17
The enhanced release resulting from the exchange of I− and OH− is expected to produce surface features that could be detected with spectroscopic and microscopic techniques. Fresh polished and leached surfaces are shown in Fig. 5a–c. No secondary phases are present at the surfaces from the SEM images from the secondary electron (Fig. 5b and c) and backscattered electron images. The IR spectrum of a leached sample (red) shows absorption peaks from 3450–3600 cm−1 with a sharp absorption peak around 3537 cm−1 (Fig. 5d), which are absent in the spectrum of the unleached sample (blue). These peaks are assigned to OH− in the channel site of the iodoapatite, which was occupied by iodide ion before the test and replaced by OH− as a result of ion exchange during the test. This result is consistent with the previous observation of both CO32− and OH− Raman peaks on the surface of iodoapatite that had been leached in a KOH/KHCO3 buffered solution of pH 11.10 Our results show that the ion exchange can also occur under neutral conditions despite of the strong pH dependence of iodoapatite dissolution.9
Fig. 5 SEM images of iodoapatite surfaces: fresh polished (a), surface leached with deionized water (b), a close-up (c), and IR spectra collected in transmission mode of unleached and leached iodoapatite and a hydroxyapatite from ref. 10 (d). |