Yanan Zouab,
Jing Heb,
Yongming Hu*b,
Rui Huangb,
Zhao Wangb and
Qibin Gu*c
aSchool of Science, Jilin Institute of Chemical Technology, Jilin 132022, P. R. China
bHubei Key Laboratory of Ferro & Piezoelectric Materials and Devices, Faculty of Physics and Electronic Sciences, Hubei University, Wuhan 430062, P. R. China. E-mail: huym@hubu.edu.cn
cDepartment of Architecture and Material Engineering, Hubei University of Education, Wuhan 430205, P. R. China. E-mail: gqibin@hue.edu.cn
First published on 8th May 2018
Nb2O5 nanorod arrays with a hexagonal phase were in situ grown on Nb foil via a facile hydrothermal method. The aspect ratio and spacing of the Nb2O5 nanorods increased upon an increase in the reaction temperature. A pair of platinum electrodes was deposited on the surface of the Nb2O5 nanorod arrays to form a hydrogen sensor. The sensor based on Nb2O5 nanorod arrays exhibited a fast and highly-sensitive hydrogen response with a sensitivity of 74.3% and a response time of 28 s toward 6000 ppm of H2 at room temperature. The Nb2O5 nanorod arrays also showed good selectivity of H2 against C2H6O, CO and NH3. The hydrogen sensing performance can be attributed to the reaction between chemisorbed oxygen species and H2. The Nb2O5 nanorods have a high aspect ratio, leading to an increase in the chemisorbed oxygen species on the surface of the [001] orientated nanorods. Moreover, arrays with a vertical structure have low quantities of junctions, which allow oxygen ions to diffuse more easily.
Nanostructured materials with a high surface-to-volume ratio are ideal for gas sensing, since gas sensing is inherently a surface phenomenon. There have been many reports on the gas sensing properties of nanostructured metal oxides, such as ZnO2, TiO2 and SnO2.3–8 However, gas sensors based on Nb2O5, an important semiconductor oxide with superior photocatalyst, gas sensing, electrochromic and biocompatibility properties9–13 due to its thermodynamically stability, chemical inertness and high refractive index,14,15 have attracted less attention than other materials. Hyodo et al. fabricated a H2 sensor based on a Nb2O5 film coupled with Pd electrodes, which exhibited a fast and sensitive H2 response at 100 °C.16 Park et al. examined the sensing properties of Nb2O5-core/ZnO-shell nanorod sensors toward H2 gas.17 The response and recovery times of the Nb2O5-core/ZnO-shell nanorods at 10000 ppm of H2 at 300 °C were 17 and 23 s, respectively. Nevertheless, the sensor has to operate at a high temperature, which results in poor selectivity because it has to respond to a number of reducing gases with relatively high sensitivities at such a high working temperature. Wang et al. reported a H2 sensor based on Nb2O5 nanowires, which exhibited a response time of 1.67 min at room temperature (RT).10 The RT response time is too long to be useful in practical applications, and may be due to the large amounts of junctions among the nanowires, which slow down the diffusion of gas molecules and increase the electron scattering.18 Several attempts have been made to decrease the resistance and the response time of network sensors. The methods resulted in either an unavoidable increase in the fabrication cost or the formation of composite materials.19 A facile approach is to grow a Nb2O5 1D nanostructure with a vertical architecture, which reduces the number of junctions within the structure, to optimize the sensitivity of the sensor. Towards this aim, the hydrothermal method has been recognized as a simple, inexpensive and low temperature method for the growth of single-crystalline oxide nanostructures.
In this work, well-crystallized Nb2O5 nanorod arrays were in situ grown on Nb foil using a one-step hydrothermal process. A hydrogen sensor was designed using the Nb2O5 nanorod arrays without any catalyst, and exhibited a highly-sensitive and selective hydrogen sensing performance at RT. Moreover, the mechanism of hydrogen sensing and performance enhancement was also discussed in detail.
The resultant nanorod phases were characterized using powder X-ray diffraction (PXRD Bruker D8A25, CuK, λ = 1.5406 Å). The morphologies and microstructures were examined using field-emission scanning electron microscopy (FESEM, JOEL JSM-7100F) and high-resolution transmission electron microscopy (HRTEM, JEOL Model JEM-2010).
Fig. 1 SEM images of the as-prepared samples synthesized at different reaction temperatures, (a) 125 °C, (b) 150 °C, and (c) 175 °C. Inset: the corresponding cross-section SEM images. |
The TEM image and selected area electron diffraction (SAED) pattern of an individual Nb2O5 nanorod obtained at 175 °C are shown in Fig. 2(a). The surfaces of the nanorod are smooth and pure. The cross-sectional width is 234 ± 20 nm and the length is 702 ± 128 nm. The SAED pattern shown in the inset demonstrates the single-crystalline nature of the hexagonal phase. The distinct lattice stripes can be clearly seen in the HRTEM image shown in Fig. 2(b). The calculated interlayer distances of (001) and (100) planes are 0.39 and 0.31 nm, which are in good agreement with the theoretical values for hexagonal Nb2O5 and indicate that [001] is the preferred growth direction.
Fig. 2 The microstructure of a single Nb2O5 nanorod obtained at 175 °C. (a) The TEM image and SAED pattern (inset); (b) the HRTEM image. |
Table 1 lists the response times of the reported hydrogen sensors with Nb2O5 nanostructures. In comparison, the as-fabricated hydrogen sensor based on the Nb2O5 nanorod arrays exhibited an ideal hydrogen response at RT. The response time to 6000 ppm of H2 is 28 s, which is shorter than that of a 2D nanofilm16 and 1D nanowire10 based sensor. Although the response time for our Nb2O5 nanorod array sensor is close to that of a Nb2O5-core/ZnO-shell nanorod based nanosensor,17 the advantages of the current system are that it can be prepared using a simple synthesis process and the nanorods have not been decorated. The low cost makes it more commercially viable for room-temperature hydrogen sensing devices.
The most quoted model for explaining the hydrogen sensing mechanism of metal oxide semiconductors is the depletion layer modulation theory.21Fig. 4 shows a schematic illustration of the response and recovery processes of the Nb2O5 nanorod arrays.22 As shown in Fig. 4(a), oxygen molecules are adsorbed onto the Nb2O5 nanorod surface in air and form oxygen ions by trapping electrons from the conduction band of Nb2O5, as expressed in the following equations:
O2(g) ↔ O2(ad) | (1) |
O2(ad) + e− ↔ O2−(ad) | (2) |
O2(ad) + 2e− ↔ 2O−( ad) | (3) |
This causes electron depletion at the surface and tends to increase the resistance, since Nb2O5 is an n-type semiconductor. It is necessary to point out that the types of the chemisorbed oxygen species depend on the temperature.23 At low temperature, O2− is usually chemisorbed. Therefore, upon exposure to a hydrogen atmosphere (Fig. 4(b)), a higher concentration of O2− species reacts with the hydrogen molecules producing water and electrons at room temperature:
2H2 + O2−(ad) → 2H2O + 2e− | (4) |
This reaction is exothermic and the H2O molecules desorb from the surface, while the electrons are released back to the Nb2O5 nanorods, thus decreasing the resistance. When the sensor is exposed to air again, the depletion layer width increases by adsorbing oxygen species, as shown in eqn (1) and (2). The resistance recovers to its initial level. In a practical environment, competition between these oxygen-removing electrons and the hydrogen gas restores these electrons. The steady state value of the resistance will depend on the hydrogen gas concentration because the concentration of oxygen is relatively constant.
Another component of the H2 sensitivity is the dissociative chemisorption of hydrogen on the Nb2O5 nanorod surface. According to previous reports, chemisorbed hydrogen on oxide surfaces is more often observed in experiments.24 During chemisorption, hydrogen acts in a surface state and produces an energy level for the transfer of charge from hydrogen to the conduction band of Nb. Therefore, an electron accumulation layer is created on the Nb2O5 nanorod surface that enhances its conductivity. When removing the ambient hydrogen using air, electron transfer takes place back to hydrogen and it desorbs. Thus, the accumulated layer of electrons disappears, and restores the original resistance of the Nb2O5 nanorod. The associated reaction is rapid and reversible at room temperature.
Moreover, the possible H2 sensitivity is related to defects such as oxygen vacancies, which serve as adsorption sites for gas species. It has been found that hydrogen molecules can bind more tightly with oxygen vacancies to increase the conductivity.23 This process is very slow at room temperature and leads to incomplete recovery.25 Therefore, the defect-related hydrogen response may not be the major mechanism of the fast hydrogen response.
The high sensitivity of our sensor can be attributed to the high aspect ratio of the Nb2O5 nanorods because the high aspect ratio increases the contact area to the ambient. Therefore, the Nb2O5 nanorod array hydrogen sensor exhibits a fast and sensitive hydrogen response performance comparing with that of the Nb2O5 film-based sensor. However, the aspect ratio of the nanowires is larger than that of the nanorods, but the response time of the device based on the nanowire net is not faster than that of our sensor, because the nanowire net contains junctions, which leads to the internal diffusion resistance of chemisorbed oxygen ions.18 This means that the net carrier density decreases with more junctions in the sensor, leading to a lengthening of the response time. The Nb2O5 nanorod arrays grown with vertical rods on the Nb substrate, moreover, the designed structure of the sensor, resulted in a current along the nanorods, that connected them to the Nb foil. As a result, by reducing the number of junctions and the oxygen ion diffusion resistance, the response time of the sensor based on Nb2O5 nanorod arrays was improved.
Fig. 5(a) shows five continuous response cycles to 6000 ppm of H2, suggesting the outstanding repeatability of this sensor. Moreover, the gas selectivity to H2 was also examined in contrast with C2H6O, CO and NH3 for this Nb2O5 nanorod array hydrogen sensor. As shown in Fig. 5(b), the sensing response to H2 gas was stronger than that of the other gases, suggesting that the sensor has excellent selectivity for H2 gas. This can be attributed to the highly reducing behaviour of the H2 gas. However, the sensor shows low sensitivities for other reducing gases, such as C2H6O, CO and NH3. Although the exact reason for this is not very clear at present, it is proposed that the molecular size may be responsible for the selectivity.26 The diameters of the C2H6O and NH3 molecules are much larger than those of H2 and CO. It is difficult for the larger molecules to diffuse into the inner layer of the nanorod arrays and react with the chemisorbed oxygen. Moreover, the bond energy of H2 (436 kJ mol−1) is much lower than that of CO (1072 kJ mol−1). Hence, it is easier to destroy the bond in H2 at a lower temperature. As a result, the Nb2O5 nanorod arrays exhibit a higher response to hydrogen against C2H6O, CO and NH3.
This journal is © The Royal Society of Chemistry 2018 |