Yang Zhou,
Jian Fang,
Hongxia Wang,
Hua Zhou,
Guilong Yan,
Hao Shao,
Yan Zhao and
Tong Lin*
Institute for Frontier Materials, Deakin University, Geelong, Victoria 3216, Australia. E-mail: tong.lin@deakin.edu.au
First published on 25th February 2019
Mechanical-to-electrical energy conversion devices show potential applications in the detection of movements. Previous studies on these sensor devices are mainly based on piezoelectricity or triboelectricity, which typically generates AC signals. In this study, a movement sensor that generated DC signals based on a conducting polymer-metal Schottky diode was prepared for the first time. Using the Al|poly(3,4-ethylenedioxythiophene)|Au device as a model, we showed that the sensor device could detect the touch and sliding movements. Both the pressure of the Al electrode touching the PEDOT surface and its sliding speed affected the voltage outputs. The device showed a high response speed of 1.7 s at 39.8 kPa. The modified device can even measure the sliding speed. The DC output allows the use of electrical energy for running other electronic devices. A conducting polymer-metal Schottky contact may be useful for the development of DC output movement sensors.
Over recent years, the rapid development in microelectronics and wireless communication has increased the demand for movement detection.15–17 Thus, highly sensitive, multifunctional motion detectors are highly desirable. Capacitive touchscreens utilize the human body as an electrical conductor to distort the electrostatic field on the screen and alter the capacitance.18–20 However, they fail to detect the insulating materials. Resistive sensors suffer from low contrast and insufficient sensitivity. Moreover, the structural complexity and high cost cause problems in their large scale production.
Recently, energy harvesters capable of converting mechanical energy into electricity have shown significant potential for motion detection applications.21,22 Movement and pressure sensors based on a triboelectric nanogenerator (TENG) and a piezoelectric nanogenerator (PENG) have been reported. TENGs generate triboelectric charges when two materials with opposite electric negative features contact and separate.23 Fan et al.24 prepared a pressure sensor using polydimethylsiloxane (PDMS) and polyester as active materials. The device was able to detect the impact from dropping water (3.6 Pa) or a falling feather (0.4 Pa) on the surface, with a low-end detection limit of ∼13 mPa. Zhu et al.25 reported a polymer nanowire TENG sensor, which showed a pressing sensitivity of up to 44 mV Pa−1 and touch sensitivity of 1.1 V Pa−1. Yang et al.9 prepared self-powered movement sensors using a single-electrode TENG mechanism, which required the moving objects to be connected with an electrode. PENGs can convert mechanical energy, vibration and hydraulic energy into electrical signals useful for the development of wearable sensors.26 Chun et al.21 prepared a self-powered sensor for the detection of motion. The sensor device consisted of piezoelectric hemispheres embedded in PDMS. It generated an output of 4.0 V and 0.13 μA cm−2. The device can sense wrist movement in various directions. Proto et al.27 compared two piezoelectric transducers, i.e., lead zirconate titanate (PZT) and polyvinylidene fluoride (PVDF), for sensing body movement. The power output generated by a single transducer in common activities was in the range of 2–46 μW cm−3, and the output signals could be further amplified using a group of devices. Wang et al.28 reported a biocompatible body movement sensor with a combination of PENG and TENG using aluminium/zinc oxide as a transparent electrode, polyvinylidene fluoride trifluoroethylene as a piezoelectric layer, and PDMS as a friction layer. This TENG–PENG hybrid device can distinguish slight body movements of the neck, finger, elbow, and ankle. However, both TENG and PENG require repeated attachment and detachment of the two active materials, and they have complex device structures.29 These issues not only narrow the application scope but also increase the fabrication difficulty. In addition, the TENG and PENG devices typically generate alternating current (AC) voltage signals, which need rectification into direct current (DC) when used for power supplying purposes (e.g. self-powered sensors). In this regard, DC sensors are promising towards self-powered applications. However, DC movement sensors based on the mechanical to electrical energy conversion principle have not been reported in the literature.
In previous studies, we have prepared a conducting polymer-metal Schottky contact energy harvester that can convert mechanical energy into DC electric signals without rectification.30 Under compressive deformation, the device can generate a DC power of 0.7 V and 62.4 μA cm−2. The devices could be used either as power suppliers or as sensors.
In this study, we report a novel movement sensor based on a conducting polymer-metal Schottky contact. Poly(3,4-ethylenedioxythiophene) (PEDOT) and aluminium were used as material models. Motion can be detected when the PEDOT-Al contact was established. The effect of Al-PEDOT mechanical interactions on electric output was examined. We showed that the PEDOT-Al Schottky contact was responsive to the touch and sliding movements. The device can sense low pressure (i.e., 4.0 kPa) and slow movement (e.g. 1.8 cm s−1). The output signals were linearly correlated to the movement speed and load. By dividing the PEDOT surface into separate segments, the device can even measure the movement speed.
During the electrochemical preparation, the thickness of the PEDOT layer can be adjusted by changing the deposition conditions. However, the PEDOT thickness affected the device stability. When the PEDOT layer was thicker than 5 μm, it had small adhesion strength and tended to delaminate off the PET substrate during contact with the Al rod. On the other hand, when the PEDOT layer was very thin, e.g. thickness < 0.5 μm, it caused uneven coverage on the Au layer; this led to a short circuit when the Al rod was attached to the film (see Fig. S4 in ESI†). In this study, we chose the thickness of 2 μm for the experiments.
The PEDOT film appeared smooth on the surface. However, under SEM, it showed a rough surface structure (Fig. 1(b)). AFM imaging was used to measure the surface roughness. The as-prepared PEDOT film had a root mean square (RMS) roughness of 316 nm.
Fig. 1(d) depicts the typical outputs generated by a short time connection of Al and PEDOT at different pressures. At the same location, the Al-PEDOT connection led to a rapid increase in voltage. In less than 2 seconds, the output value reached a plateau when PEDOT received a pressure in the range of 4.0–199.0 kPa, suggesting a reasonably high response speed. When the Al rod detached from the PEDOT surface, the output sharply turned zero. The pressure applied to the PEDOT surface through the Al tip affected the output value. Higher output values were generated from higher attachment pressure. This trend can be explained by the fact that higher pressure results in larger deformation on PEDOT that leads to larger strain.9 As expected, the device output during the attachment and detachment process was in single polarity, showing a DC voltage characteristic. This DC output feature is similar to that of the layered film Al|PEDOT|Au devices reported in our previous study.31
To verify the Schottky contact, we obtained the I–V curve of the Al|PEDOT|Au setup. Indeed, the Schottky diode feature formed in the device (see Fig. S1 in ESI†).
Fig. 1(e) shows the influence of pressure on the output value when the Al rod was attached to the PEDOT film. Initially, when the Al tip was gently attached to the PEDOT surface at a pressure of 4.0 kPa, the output was maintained at 200 mV with a slight decay in the value. When larger pressure, e.g. 39.8 kPa, was loaded on the Al tip, the voltage rapidly increased to 400 mV and then stabilized at 400 mV. A further increase in the pressure from 39.8 to 79.6 kPa led to a smaller increase in the output value. However, when the pressure was above 79.6 kPa, the output voltage was less sensitive to pressure. This was presumably because the deformation level of the underlying PEDOT film reached its limit. This trend is different from that in the attachment-detachment mode. Since the attachment of Al on PEDOT involves an impact at a certain speed, and extra kinetic energy causes a larger impact deformation in the initial stage.
Fig. 1(f) shows the output profile when the Al rod is attached to the PEDOT surface for a long time. During 16 hours of constant connection, the output voltage decayed from initial 600 mV to 100 mV. The inset chart in Fig. 1(e) shows an enlarged view of the output signal in the first 600 seconds. A stable output was observed before 200 seconds, followed by a slump in the output value. For practical detection, 200 seconds of stable output is adequate for signal collection.
Fig. 2(b) shows the output signals generated when the Al rod moved back and forth within the same location at a certain speed, which ranged from 0.18 to 0.88 cm s−1. The negative speed indicated that the movement was in the opposite direction. Since the acceleration and deceleration took less than 0.01 second, the acceleration and deceleration times were neglected. The output signals generated quasi-linearly increased with the increasing speed. Apart from the correlation between the speed and the output signals, the shapes of the two output signals generated within the same location and speed but in the opposite directions were almost symmetric. Due to the identical pressure and movement speed, this similarity was attributable to the similar PEDOT deformation.
We also found that the application of a large pressure during sliding could lead to a damage of the PEDOT layer. When the pressure was in the range of 79.6–159.2 kPa, the sliding did not cause an apparent damage to PEDOT, and the test was repeatable. Under a pressure of 159.2 kPa and an Al movement speed less than 1 cm s−1, the device showed reasonable repeatability.
Fig. 2(c) shows the output results generated by the movement of the Al rod at different acceleration modes. During testing, the Al rod was moved at 0.02, 0.18, and 0.53 cm s−2 along the PEDOT surface (i.e. top, middle and bottom plots, respectively) within the same distance. The maximum speed was controlled at 0.18 cm s−1. When the Al tip moved at the accelerated speed of 0.02 cm s−2 and then decelerated at an opposite accelerated speed, i.e. −0.02 cm s−2, the output voltage increased with an increase in the speed and then reduced correspondingly. However, the maximum output occurred just after the maximum speed value. This voltage hysteresis was caused by the variation of strain. The acceleration phase gradually increased the strain and the deformation force, whereas the deceleration phase reduced these forces. As a result, a combined effect on the voltage output occurred. During the constant speed period, the output signals continued to fluctuate during the movement presumably because of the variation in the PEDOT deformation level and strain. In this circumstance, the movement of the Al rod was considered to be the same as that presented in Fig. 2(b), where high acceleration and deceleration speeds were applied. When the acceleration speed was increased to 0.53 cm s−2, a similar trend was observed.
Note that the output signals in the deceleration state showed a decreased trend; however, the output values were slightly higher when compared with those in the acceleration stage (Fig. 2(c)). This is attributed to the output feature of the Au|PEDOT|Al device. When the device is kept in the deformed state, the voltage output slowly decays (see Fig. 1(e)). In the acceleration stage, the deformed area was just deformed since the contact with the Al tip contributed more to the voltage outputs.
Fig. 2(d) shows the effect of pressure on the output profile when the Al tip moved along the PEDOT surface at 0.18 cm s−1. When the tip pressure was increased, higher output value was obtained, whereas the output profile had a very small change. Therefore, this Schottky device is responsive to both the touch and the sliding movements. Fig. 2(e) shows a comparison of three waves, in which the waves A & B were generated from repeated sliding in the same location, whereas the wave C was generated at different locations of the same PEDOT film. Herein, the Pearson's correlation coefficient between two input data series was employed to characterize the output waves. The Person correlation coefficient was calculated by the eqn (1):
(1) |
For the output waves A and B, the r value was calculated as 0.93. An r value close to +1 suggests high similarity between two waves.32 Therefore, sliding in the same location leads to similar outputs. The r value between the waves A and C was calculated as 0.35 and that between waves B and C was calculated as 0.19, indicating dissimilarity. These results suggest that high similarity in the sliding-caused output signals can be generated only at the same location with identical pressure and speed. This location-dependent output was attributed to the variance in surface morphology of the PEDOT layer, which originated from the sample fabrication process. To verify this, we characterized the surface morphology of the PEDOT film at the sliding location. Fig. 2(f) and (g) show the 2D and 3D AFM images of a typical 15 μm × 15 μm area selected from the PEDOT film, where the agglomeration of PEDOT nanoparticles along with high surface roughness (i.e., 316 nm RMS roughness) can be observed. The maximum height difference within this area was more than 2 μm. We have further characterized the surface morphology of two different locations within the same PEDOT film via SEM, where the topography of two locations varies significantly (see Fig. S2 in ESI†). This variation in surface morphology results in different PEDOT-Al contact areas and deformation levels of the local PEDOT; this subsequently affects the output signals. A uniform PEDOT film with a smooth surface would allow to have a similar output upon sliding the rod at different locations of the same film.
Apart from Al rods, pencils with different hardnesses (i.e. 6H and 6B) were used as a tip for the detection of movement. In this case, the tip was covered with an aluminium sheet (see the experimental illustration in Fig. 3(a)). Fig. 3(b) shows the effect of the movement speed on the output feature generated by the devices using an Al-covered pencil as a probe. At the same weight load, both pencils were driven to slide on the PEDOT surface at a speed in the range of 0.18–1.8 cm s−1. A quasi-linear relationship between the speed and the resulting maximum output value was observed for the pencil-involved devices regardless of the pencil hardness. The output voltage increased with the increasing tip traveling speed. The device with the 6H pencil tip showed slightly larger output values when compared with that with the 6B pencil; this indicated that tip hardness had an influence on the output. Fig. 3(c) shows the influence of tip pressure on the output values. Higher output voltages resulted from larger pressure on the PEDOT layer.
(2) |
Fig. 3(i) provides a comparison of the outputs generated from a continuous PEDOT film and the film with five gaps (5 mm width). Herein, the standard error (σ) of each output was calculated. The σ of the output signals generated from the continuous PEDOT was 39.8 mV, whereas the σ of the output signals generated from the film with 5 gaps was 8.4 mV. The decrease in the volatility of the output suggests that more stable results are produced by the patterned PEDOT films.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/c9ra00120d |