Open Access Article
This Open Access Article is licensed under a Creative Commons Attribution-Non Commercial 3.0 Unported Licence

Detection and quantification of exhaled volatile organic compounds in mechanically ventilated patients – comparison of two sampling methods

Pouline M. P. van Oort a, Iain R. White *bc, Waqar Ahmed bd, Craig Johnson b, Jonathan Bannard-Smith e, Timothy Felton ed, Lieuwe D. Bos a, Royston Goodacre f, Paul Dark ed and Stephen J. Fowler ed
aDepartment of Intensive Care, Amsterdam UMC – location Academic Medical Centre (AMC), Amsterdam, the Netherlands
bManchester Institute of Biotechnology, University of Manchester, Manchester, UK
cLaboratory for Environmental and Life Sciences, University of Nova Gorica, Nova Gorica, Slovenia
dDivision of Infection, Immunity and Respiratory Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, and NIHR Manchester Biomedical Research Centre, University of Manchester, Manchester, UK
eManchester Academic Health Science Centre, Manchester University Hospitals NHS Foundation Trust, Manchester, UK. E-mail: stephen.fowler@manchester.ac.uk
fDepartment of Biochemistry, Institute of Integrative Biology, University of Liverpool, UK

Received 20th June 2019 , Accepted 9th October 2020

First published on 21st October 2020


Abstract

Exhaled breath analysis is a promising new diagnostic tool, but currently no standardised method for sampling is available in mechanically ventilated patients. We compared two breath sampling methods, first using an artificial ventilator circuit, then in “real life” in mechanically ventilated patients on the intensive care unit. In the laboratory circuit, a 24-component synthetic-breath volatile organic compound (VOC) mixture was injected into the system as air was sampled: (A) through a port on the exhalation limb of the circuit and (B) through a closed endo-bronchial suction catheter. Sorbent tubes were used to collect samples for analysis by thermal desorption-gas chromatography-mass spectrometry. Realistic mechanical ventilation rates and breath pressure–volume loops were established and method detection limits (MDLs) were calculated for all VOCs. Higher yields of VOCs were retrieved using the closed suction catheter; however, for several VOCs MDLs were compromised due to the background signal associated with plastic and rubber components in the catheters. Different brands of suction catheter were compared. Exhaled VOC data from 40 patient samples collected at two sites were then used to calculate the proportion of data analysed above the MDL. The relative performance of the two methods differed depending on the VOC under study and both methods showed sensitivity towards different exhaled VOCs. Furthermore, method performance differed depending on recruitment site, as the centres were equipped with different brands of respiratory equipment, an important consideration for the design of multicentre studies investigating exhaled VOCs in mechanically ventilated patients.


Introduction

Hundreds of volatile organic compounds (VOCs) are present in human breath,1 either produced by the host through metabolic processes in health and disease, and/or after ingestion (e.g. food, medications),2 microbiota3 or the environment.4 Exhaled breath analysis has shown widespread diagnostic potential in infectious and inflammatory lung diseases, for example in COPD, asthma, cystic fibrosis, tuberculosis and pneumonia.5–9 In mechanically ventilated patients on the intensive care unit (ICU), exhaled breath analysis has shown potential for diagnosing diseases including acute respiratory distress syndrome (ARDS)10 and ventilator-associated lower respiratory tract infections (VA-LRTIs),11–13 with the added advantage that it is non-invasive and does not cause any stress to the patient.

Gas chromatography-mass spectrometry (GC-MS) is the current gold standard for detection and identification of exhaled VOCs.3 GC-MS is not suitable for the bedside and so several breath sampling methods have been investigated to enable capture and transportation of samples off-site. Previous studies reported the use of glass syringes and gas sampling bags.14–16 Although they are low cost and have been used to capture breath gas in many studies, they are associated with loss of metabolites and sample contamination for example dimethylacetamide, phenol, 2-methyl-1,3-dioxalane.17–19 Stainless steel tubes filled with sorbent material pre-concentrate the breath sample and are suitable for transportation and storage with minimal loss of VOCs.20 Needle trap devices have also been used to trap VOCs.21,22 Currently there is no consensus regarding the ideal method for bedside breath sampling and transport although the need to develop a strategy to achieve this is widely accepted.23

Standardization of VOC sampling methods in mechanically ventilated patients remains challenging and is contingent on fully defining sampling systems in terms of their analytical performance, including dynamic range, detection limit, noise and the sensitivity of matrix effects towards ambient changes. Previously, two methods of VOC capture using different sampling sites within the ventilator circuit have shown to be safe and feasible: a semi-invasive method using a closed endo-bronchial suction catheter,11 and a completely non-invasive technique whereby samples are diverted through a port on the exhalation limb of the ventilator circuit.24 The aim of this study was to compare these two different breath sampling techniques on a circuit optimised for breath VOC collection, utilising a test-lung device as a model for patient settings in the ICU. We hypothesized that by sampling at a position further upstream (nearer to the patient) within the ventilator circuit, larger abundances of VOCs would be detectable as they are measured closer to their source of origin. In order to evaluate the results from the test circuit, detection limits are compared to VOC levels obtained from patients enrolled in the National Institute for Health Research (NIHR) BRAVo (BReath Analysis in Intensive Care: Proof of Concept for Non-Invasive Diagnosis of Ventilator Associated Pneumonia) project.

Methods

Study outline

The research plan comprised: (1) the construction of a ventilator circuit using a “dummy” lung that integrated equipment for both sampling methods; (2) introduction of a mix of VOCs (representative of human breath) into the circuit for sorbent tube sampling and analysis; and (3) comparison of the analytical limits of the system for both methods to breath data sampled from 40 patients recruited at two centres participating in the BRAVo study.

The ventilator test circuit

The ventilator test circuit consisted of a mechanical ventilator (840 Puritan Bennett, Carlsbad, CA, USA), a Heat and Moisture Exchanger (HME; Intersurgical, Wokingham, UK), a closed suction catheter (three brands were tested, from: Westbourne Medical Ltd, Cheadle, UK (from now on referred to as ‘catheter 1’); GB UK Healthcare, Selby, UK (catheter 2); and Kimberly-Clark, West Malling, UK (catheter 3)) and an endotracheal tube size 8 (Smiths-Medical, Ashford, UK) in line with a test lung device (MAQUET, Solna, Sweden), connected with polyfluoroacetylene (PFA) tubing (type PFA-T2-030-100:1/8′′ OD and PFA-T4-062-100:1/4′′ OD, Swagelok, Warrington, UK). A small piece of corrugated tubing – delivered in the same package as catheter 3 – was inserted between the endotracheal tube and test lung device to mimic anatomical dead space. The ventilator circuit was connected to cylinders of O2 and medical air (BOC Ltd, Middlesbrough, UK). The mechanical ventilator was set at a pressure-controlled mode with positive end-expiratory pressure (PEEP) 6.0 cm H2O, peak inspiratory pressure 23 cm H2O, tidal volume 400 mL, frequency 12 breaths per min, inspiratory-to-expiratory time ratio 1[thin space (1/6-em)]:[thin space (1/6-em)]2, 100% O2.

A schematic representing the ventilator circuit is displayed in Fig. 1. Two breath sampling methods were investigated: (A) a non-invasive technique collecting air from the external ventilator connection circuit based on ref. 20 and (B) a semi-invasive technique using a suction catheter inserted via the endotracheal tube based on ref. 11. Using a precision air-sampling pump (Escort ELF pump, Supelco, Dorset, UK), air samples of 1.2 L were collected at a flow of 0.5 L min−1 using 100% O2 in order to mimic ICU setting. Air was drawn through stainless steel tubes (0.25 inch outer diameter, 3.5 inch length) packed with 200 mg ± 1.7% of TenaxGR adsorbent (35/60, Markes International, Llantrisant, UK). TenaxGR was chosen for its hydrophobic properties.


image file: c9an01134j-f1.tif
Fig. 1 Schematic overview of the ventilator circuit. The non-invasive technique (A) collects air diverted through the side limb of the circuit. The semi-invasive method (B) samples air from the endotracheal tubing via a suction catheter; the position of the tip of the suction catheter is indicated by the end of the solid black line below component number 3. 1: T-piece connector; 2: endotracheal tube; 3: dead space; 4: suction catheter; 5: steel sorbent tube; A: non Invasive sampling site; B: semi-invasive sampling technique.

For the semi-invasive sampling method B (Fig. 1, red circled B) “inspiratory” airflow followed the route (in consecutive order): air/O2 cylinder – air/O2 mechanical ventilator hoses (3 M air hose and 3 M O2 hose; MEC Medical Ltd, Hitchin, UK) – mechanical ventilator – corrugated tubing (Intersurgical) – T-piece connector (GE Healthcare Finland, Helsinki, Finland) – HME – closed suction catheter – endotracheal tube – small piece of corrugated tubing – test lung device. During the simulation of expiration and subsequent air sampling, the route was as follows: test lung device – small piece of corrugated tubing – endotracheal tube – closed suction catheter – PFA tubing (approximately 50 cm PFA-T2-030-100:1/8′′ OD, both ends connected to approximately 8 cm of PFA-T4-062-100:1/4′′ OD; Swagelok, Warrington, UK) – steel adsorbent tube. The inspiratory airflow route for the non-invasive method (Fig. 1, red circled A) was: air/O2 cylinder – air/O2 mechanical ventilator hoses – mechanical ventilator – corrugated tubing (Intersurgical) – T-piece connector (GE Healthcare Finland) – HME – endotracheal tube – small piece of corrugated tubing – test lung device. The expiratory route was: test lung device – small piece of corrugated tubing – endotracheal tube – HME – T-piece connector – PTFE tubing – steel adsorbent tube. Before attaching the steel adsorbent tubes and collecting air samples the apparatus was purged for 1 min at 0.5 L min−1. Experiments were performed at Salford Royal Hospital NHS Foundation Trust, UK.

In order to investigate the extent to which different materials give rise to analytical contamination, three brands of closed suction catheter were tested within the circuit as above. Filtered room air was purged through each system and collected onto sorbent tubes. Two of these catheters (catheter 2 and 3) were used to acquire breath from ICU patients at the two Manchester sites; these measurements therefore provided the background signal from which detection limits were ascertained.

VOC test mix

A VOC mix (Table 1) was designed to test the dummy lung system against a wide range of compounds relevant to breath. The 24 component mix, an extended panel based on the standard described by Basanta et al.,25 comprised compounds of various chemical classes to examine how analytical performance and sampling efficiency changes with properties such as polarity and solubility. For example, the heterocyclic compound 1,4-dioxane was included as it was previously reported as an endogenous component in mechanically ventilated patients’ breath20 whilst the bicyclic monoterpene 3-carene was included as it has been identified as elevated in the breath of infected mechanically ventilated patients.11 VOCs were dissolved in high purity methanol (HPLC grade) and stock concentrations were determined from calibration curves selecting the concentration above the limit of quantification. Following serial dilution, different concentrations were injected into the dummy lung system (20 μL) inside extendable tubing that connected the endotracheal tube to the dummy lung (position element 3 on Fig. 1). Following injection of the VOC mix into the dummy lung system, samples were collected on adsorbent tubes and analysed by TD-GC-MS. A calibration standard loading rig (CSLR, Markes) was used to load the same concentration range of the test mix directly onto sorbent tubes, to allow comparison of peak intensities of target VOCs to results from the test circuit, and thus determine the mass of VOCs recovered at each sampling point.
Table 1 Physical and chemical properties of the VOC test mix
Compound Conc. in 1° stock/(mmol) RMM/(g mol−1) Quant ion RT (min) log(KOW) k H/(atm m3 mol−1) VP/(mmHg)
RMM = relative molecular mass; KOW = octanol/water partition coefficient; kH = Henry's law constant; VP = vapour pressure. KOW, KH and VP are experimentally derived values reported in Episuite v4.1.a KOWWIN v1.68 estimated value.b Estimate from bond method in HENRYWIN v3.2.c Mean of Antoine and Grain methods.d Modified Grain method.
Acetone 100 58 58 1.72 −0.24 3.50 × 10−5 2.32 × 102
Isoprene 100 68 67 1.73 2.42 7.67 × 10−2 5.50 × 102
Benzene 25 78 78 2.4 2.13 5.55 × 10−3 9.48 × 101
3-Pentanone 25 86 57 2.66 0.91 8.36 × 10−5 3.77 × 101
1,4-Dioxane 55 88 88 2.77 −0.27 4.80 × 10−6 3.81 × 101
Pyridine 25 79 79 3.18 0.65 1.10 × 10−5 2.08 × 101
Toluene 10 92 91 3.49 2.73 6.64 × 10−3 2.84 × 101
Octane 25 114 85 3.94 5.18 3.21 × 100 1.41 × 101
Butyl acetate 25 116 56 4.2 1.78 2.81 × 10−4 1.15 × 101
p-Xylene 25 106 91 5.27 3.15 6.90 × 10−3 8.84 × 100
Nonane 25 128 57 5.87 5.65 3.40 × 100 4.45 × 100
Benzaldehyde 25 106 77 7.31 1.48 2.67 × 10−5 1.27 × 100
1-Heptanol 25 116 70 7.51 2.62 1.88 × 10−5 2.34 × 10−1
Decane 25 142 57 8.27 5.01 5.15 × 100 1.43 × 100
3-Carene 10 136 93 8.56 4.38 1.07 × 10−1b 2.09 × 100c
Limonene 25 136 68 9.03 4.38 3.19 × 10−2 1.44 × 100
Undecane 10 156 57 10.83 5.74a 1.93 × 100 4.12 × 10−1
Nonanal 50 142 57 10.94 3.27b 7.37 × 10−4 3.70 × 10−1
Tetralin 10 132 104 12.46 3.49 1.36 × 10−3 3.68 × 10−1
Dodecane 10 170 57 13.37 6.10 8.18 × 100 1.35 × 10−1
1-Methylindole 10 131 130 15.17 2.72 1.89 × 105b 4.71 × 10−2d
Tridecane 10 184 57 15.81 6.73 2.88 × 100 5.58 × 10−2
Tetradecane 10 198 57 18.13 7.20 9.20 × 100 1.16 × 10−2
Pentadecane 10 212 57 20.33 7.71a 1.26 × 101 3.43 × 10−3


Breath sampling

In order to evaluate results from the dummy lung experiments against realistic, meaningful data, a subset of samples collected as part of the BRAVo project were examined. During BRAVo, mechanically ventilated patients provided breath samples within 24 hours of clinical suspicion of ventilator-associated pneumonia (VAP). The first 20 patients recruited at two centres participating in the study (Manchester University NHS Foundation Trust – Manchester Royal Infirmary, and Salford Royal NHS Foundation Trust in Manchester, UK) were included in this analysis. These results have been used only to provide a representative dataset of exhaled VOC concentration samples distributions in mechanically ventilated patients (irrespective of clinical status) and an in-depth analysis of the VOC results is beyond the scope of the present study. Patient information letters, informed consent forms and the study protocol were approved by the National Health Service Research Ethics Committee (reference 15/NW/0393). Formal assent was sought with a designated consultee at time of inclusion and deferred consent was obtained for patients who regained capacity.

Both methods were used to sample breath at the two sampling sites: 1.2 L of breath was collected at a flow of 0.5 L min−1 onto TenaxGR adsorbent tubes (Markes International, Llantrisant, UK). Samples were collected in duplicate (i.e., 40 samples were submitted from each centre for each sampling method). After sampling, the tubes were returned to the Manchester Institute of Biotechnology, University of Manchester, UK, for analysis by TD-GC-MS.

Thermal desorption gas chromatography-mass spectrometry

TenaxGR adsorbent tubes were analysed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). A two stage desorption process was performed based on the parameters outlined in Table 2. Prior to analysis all tubes were loaded with an internal standard (100 μL of 1 ppmV p-bromofluorobenzene in N2) and all tubes were desorbed twice to determine carryover and for assurance that efficient desorption had taken place.
Table 2 Details of the TD GC-MS method
Thermal desorption unit Model Markes International TD100
Cold trap model U-T11GPC-2S general purpose carbon (Markes International)
Cold trap temp 0 °C
Primary desorb 280 °C for 5 min (splitless)
Secondary desorb 280 °C for 3 min (splitless)
 
Chromatography instrument Model Agilent 7890B GC
Column model DB-5 ms GC (0.25 μm, 0.25 mm × 30 m; Agilent Technologies)
Carrier gas Constant pressure (10 kPa) He
Oven program Initial temperature of 40 °C; 170 °C at 6 °C min−1; 190 °C at 15 °C min−1
Postrun 250 °C (2 min)
 
Mass spectrometer Model Agilent 7010 series triple quadrupole mass spectrometer
Source EI+ at 70 eV (200 °C)
Scan m/z range 40–500 (5 Hz)
 
Reconditioner Model Markes TC20
Carrier gas 50 mL min−1 N2
Oven program 330 °C for 1 h
Dry purge (when required) 50 mL min−1 N2 for 4 min


A targeted deconvolution was performed on 0.1 min time windows surrounding the retention times presented in Table 1 and target quantifier ions were integrated using MassHunter's Agile2 integrator (Agilent Technologies, Stockport, UK).

Results

Realistic steady state mechanical ventilation rates and breath pressure–volume loops were established in the ventilator circuit. By comparing peak intensities of target VOCs to results from direct injections of the test mix onto sorbent tubes, the mass of VOCs recovered at both sampling points could be ascertained (Fig. 2). All calibration curves were linear over several orders of magnitude. Also apparent in Fig. 2 is the clear difference in recovery between sampling methods: the semi-invasive method (method B) is associated with more VOC recovery onto the sorbent tubes.
image file: c9an01134j-f2.tif
Fig. 2 The amount of VOCs collected onto sorbent tubes versus the amount of VOCs injected into the dummy lung system, for both sampling methods. Sampling method A = non-invasive; sampling method B = closed suction catheter semi-invasive method. Points are the mean of 3 measurements and error bars show standard deviations.

Comparing abundances of target VOCs between both sampling methods

By plotting masses recovered using method B versus method A, a clear relationship was observed whereby only 60% of the VOC mass collected using method B (the semi-invasive method) was recovered for method A (the non-invasive method) (Fig. 3). This relationship held for most VOCs, regardless of compound class. This is consistent with the sampling position for method B: as it is located further upstream within the ventilator circuit, analytes are subjected to less turbulent mixing with deadspace air as they are collected closer to their source. The compounds that deviated from this were 1-methylindole, 1-heptanol, and benzaldehyde, where much lower proportions of VOCs were sampled using method A compared to method B (at 2%, 15%, and 24% respectively). These compounds all exhibit a combination of kH below 1 × 10−4 atm m3 mol−1 and low vapour pressure (approximately 1 mmHg or less) and thus likely reflect interaction between breath VOCs and the materials and surfaces within the ventilator circuit, thus exaggerating the loss of recovery with further distance from source.
image file: c9an01134j-f3.tif
Fig. 3 Mass of VOCs recovered using the non-invasive method (method A) versus the semi-invasive method (method B), for all VOCs in the mix except for 1-methylindole, 1-heptanol, and benzaldehyde. Grey dashed line = line of best fit; red dashed line = unity gradient (y = x).

Comparing contaminating signals associated with the use of different closed suction catheters

When different closed suction catheters were integrated into the dummy lung circuit, very different background signals were observed. Catheters must be flexible for use and are therefore constructed from elastomers and silicon based plastics, which are often associated with the emission of solvents and volatile species. Table 3 shows the VOCs that gave rise to the largest signals for each brand of catheter. All compounds were identified based on their match hit with the NIST 14 library (>800 reverse match) and are therefore considered MSI level 2.26 Observed n-alkane retention indices compare well with literature values (comparable to the tolerance observed for the MSI level 1 compounds reported in Table 4). Several compounds are common to all three catheters, however the pattern of their emission differs markedly. For example, cyclohexanone, 2-ethyl-1-hexanol and cyclic siloxanes all make up for a significant proportion of the total ion count (TIC). Whilst these, alongside compounds such as 1,2-dichloroethane, are widely considered to be exogenous species, other compounds such as 2-butanone and monoterpenes may potentially be important breath markers.
Table 3 The top 10 most abundant species analysed in background air using sampling method B with three different catheters
  VOCs associated with catheter 1 (% TIC) RT/(min) RIobs RILit Δ RT/(s)
1 Cyclohexanone (10%) 5.8 895 891 (ref. 27) 4
2 2-Ethyl-1-hexanol (7%) 9.0 1029 1035 (ref. 28) 9
3 1,3-Di-tert-butylbenzene (5%) 14.8 1258 1249 (ref. 29) 13
4 Dodecamethylcyclopentasiloxane (4%) 16.5 1329 1341 (ref. 30) 17
5 3-Carene (3%) 8.6 1011 1010 (ref. 31) 2
6 Decamethylcyclopentasiloxane (3%) 12.2 1156 1165 (ref. 30) 13
7 p-Xylene (3%) 5.3 868 865 (ref. 31) 3
8 α-Pinene (3%) 6.7 934 939 (ref. 32) 8
9 1,2-Dichloroethane (3%) 2.3 648 649 (ref. 33) 0
10 3,7-Dimethylnonane (2%) 9.2 1035 1036 (ref. 34) 2

  VOCs associated with catheter 2 (% TIC) RT/(min) RIobs RILit Δ RT/(s)
1 Cyclohexanone (21%) 5.8 894 891 (ref. 27) 3
2 Decamethylcyclopentasiloxane (9%) 12.3 1158 1165 (ref. 30) 11
3 Dodecamethylcyclopentasiloxane (6%) 16.5 1328 1341 (ref. 30) 17
4 2-Ethyl-1-hexanol (6%) 9.0 1030 1035 (ref. 28) 8
5 Tetradecamethylcycloheptasiloxane (5%) 20.3 1500 1516 (ref. 30) 21
6 α-Pinene (4%) 6.7 934 939 (ref. 32) 7
7 β-Pinene (4%) 7.7 978 980 (ref. 35) 3
8 Ethyl acetate (3%) 2.1 614 612 (ref. 31) 1
9 Isophorone (2%) 11.4 1122 1124 (ref. 28) 2
10 p-Xylene (2%) 5.3 868 865 (ref. 31) 4

  VOCs associated with catheter 3 (% TIC) RT/(min) RIobs RILit Δ RT/(s)
The VOCs printed in italics are shared between the three suction catheters.a Estimated n alkane retention index reported in NIST v14. RIobs is the retention index calculated from observed retention times; RIlit is the retention index reported in literature; ΔRT is the difference between the observed retention time and the retention time calculated from RIlit.
1 Dodecamethylcyclopentasiloxane (11%) 16.5 1328 1341 (ref. 30) 17
2 Decamethylcyclopentasiloxane (11%) 12.3 1158 1165 (ref. 30) 11
3 Tetradecamethylcycloheptasiloxane (10%) 20.3 1500 1516 (ref. 30) 21
4 2-Ethyl-1-hexanol (5%) 9.0 1029 1035 (ref. 28) 9
5 2,5-Dimethylhexane-2,5-dihydroperoxide (5%) 17.3 1365 1367a 3
6 Cyclohexanone (5%) 5.8 894 891 (ref. 27) 6
7 2-Butanone (3%) 2.0 601 602 (ref. 32) 0
8 p-Xylene (3%) 5.3 868 865 (ref. 32) 3
9 Acetone (3%) 1.7 500 500 (ref. 32) 0
10 Dodecane (3%) 13.4 1200 1200 1


Table 4 Retention indices and method detection limits for VOCs sampled in the ICU
Compound RIObs RILit Δ RT /(s) S RI S RI Method detection limit/ppbV
Method B Method A Method B (site 1) Method B (site 2) Method A (both sites)
RIobs = retention indices calculated from breath samples; RIlit = literature retention index; ΔRT is the difference between the observed retention time and the retention time calculated from RIlit; SRI is the standard deviation in retention indices.
Acetone 504 500 (ref. 31) 1 8 6 6.28 5.60 1.25
Isoprene 515 520 (ref. 36) 1 9 7 0.10 0.22 0.21
Benzene 660 657 (ref. 31) 1 2 2 0.09 0.25 0.13
3-Pentanone 700 689 (ref. 31) 4 7 7 2.13 1.11 1.39
1,4-Dioxane 707 705 (ref. 37) 2 1 1 0.02 0.13 0.12
Pyridine 740 736 (ref. 31) 3 3 3 0.12 0.14 0.06
Toluene 764 760 (ref. 31) 3 0 1 0.17 0.19 0.14
Octane 800 800 0.14 0.10 0.12
Butyl acetate 813 811 (ref. 32) 2 6 1 0.03 0.05 0.06
p-Xylene 868 865 (ref. 31) 3 29 0 2.80 4.20 0.48
Nonane 900 900 0.09 0.03 0.13
Benzaldehyde 961 960 (ref. 32) 2 8 1 1.00 0.39 1.33
1-Heptanol 969 969 (ref. 31) 1 6 1 0.56 0.21 0.55
Decane 1000 1000 0.35 2.36 0.32
3-Carene 1011 1010 (ref. 31) 1 1 1 3.46 1.29 0.13
Limonene 1030 1031 (ref. 38) 2 1 0 0.77 1.18 0.45
Undecane 1100 1100 0.83 0.15 0.28
Nonanal 1105 1105 (ref. 38) 1 1 0 2.67 0.60 1.96
Tetralin 1165 1163 (ref. 27) 3 1 1 0.10 0.06 0.02
Dodecane 1200 1200 0.11 0.80 0.30
1-Methyl indole 1276 1273 (ref. 27) 4 5 5 0.02 0.01 0.01
Tridecane 1300 1300 0.11 0.03 0.49
Tetradecane 1400 1400 0.08 0.13 0.32
Pentadecane 1500 1500 0.01 0.01 0.09


Comparing analytical limits between sampling methods

Table 4 shows the method detection limits (MDLs) calculated for each sampling method (3σ) and for the two sites where patients were recruited. The results from the dummy lung work were generalized to apply to both sites for method A. For method B, two sets of MDLs were obtained one for each centre, representing the different brands of closed suction catheter used in their equipment. A wide range of MDLs are presented in Table 4 reflecting not only the direct interference from gases such as 3-carene that are emitted by the suction catheter, but also indirect interference from co-eluting compounds. This is apparent on examination of the retention indices presented in Table 4, calculated from breath samples collected from mechanically ventilated patients. For both methods, early-eluting compounds are associated with a wider spread of RI values. These compounds elute in a busy part of the chromatogram during trap injection. However, midway through the chromatograms the spread in RI values becomes much wider for method B (particularly for the compound p-xylene, also listed in Table 3).

Comparing analytical limits to breath data

To evaluate the MDLs listed in Table 4, data obtained following the analysis of breath from 40 mechanically ventilated patients were investigated to determine the proportion of results above the MDLs for both sampling methods (Fig. 4). Whilst based on Fig. 2 the selected compounds all displayed a greater degree of VOC recovery for method B, the findings represented in Fig. 4 exemplify the complexity of the system under study. Benzene, for example, has a higher proportion of results above the MDL for method B at site 1. Conversely, at site 2, a higher proportion of results are above the MDL for method A. Benzene, a known trap artefact, is likely to be affected by the presence of the closely eluting compound, 1,2-dichloroethane. Pyridine provides another example where background contamination likely affects the MDL and at both sites method A appears to be more successful in detecting the compound. Butyl acetate is associated with the opposite effect; in this case the larger recovery of exhaled VOCs obtained by method B leads to better MDLs and higher proportions of the compound are detected. Similarly the same effect is observed for nonane, albeit with a smaller proportion of the dataset measured at levels above the MDL.
image file: c9an01134j-f4.tif
Fig. 4 The proportion of results above the MDL for both sampling methods used to obtain breath samples from two ICUs (N = 40, 2 replicates at each site).

Fig. 5 displays the proportion of the breath dataset above the MDL for all 24 compounds under study. At site 1, using method B to sample breath resulted in a significant increase in the number of compounds measured at detectable levels. Method A and method B are better suited to sampling different compounds however at site 2, the proportion of the data set above the MDL is approximately even. In this regard, the two sampling techniques complemented one another. A full evaluation of the suitability of these sampling methods towards sampling breath in mechanically ventilated patients may only be possible when target compounds have been identified and biomarkers indicative of infection are known.


image file: c9an01134j-f5.tif
Fig. 5 The proportion of results above the MDL for both sampling methods used to obtain breath samples from two ICUs based on all 24 compounds under study (N = 40, 2 replicates at each site).

Discussion

A ventilator circuit was constructed that enabled thorough ex vivo testing of two methods for capturing breath in mechanically ventilated patients. A clear difference in VOC recovery was seen between both sampling methods: method B (the semi-invasive method) was associated with larger abundances of VOCs sampled onto the sorbent tubes, compared to the non-invasive method.

The dynamic range of the system appeared to cover several orders of magnitude, appropriate for the wide concentration distributions frequently observed in breath research. The observed larger absolute sensitivities for method B (the semi-invasive sampling method) are likely explained by the proximity to the sampling position closer to the source of origin of the VOCs. Also the position of the HME filter (between the source of VOCs and the sampling tube) may contribute to a lower absolute sensitivity for method A. Several less volatile, more polar species were recovered in significantly lower proportions using the non-invasive method compared to the semi-invasive method, likely reflecting interaction between breath VOCs and surfaces downstream of the ventilator circuit. However, this enhancement in recovery for method B did not necessarily translate to better MDLs, largely due to interference from contaminants within the sample matrix.

The two ICUs use different closed suction catheters (employed in method B), giving rise to varying levels of analytical contamination. These contaminants affected MDLs, either directly as exogenous sources of VAP-relevant species, or indirectly by affecting the chromatography of target compounds. Exploratory experiments whereby suction catheters were purged for over an hour showed a reduction in contamination (data not shown), however a significant proportion still remained. The catheters used in mechanically ventilated patients must be flexible in order to follow the anatomical routes of the upper respiratory system, and clinical ICU practice is restricted to CE marked equipment. Therefore, replacing the catheters with bespoke tubing made from lower emitting but more rigid materials (e.g., PTFE) is not an option. One of the most abundant VOCs emitted in catheter headspace was cyclohexanone, an organic solvent involved in the production process of certain medical devices containing polyvinyl chloride (e.g. endotracheal tubes, intravenous fluid bags, extracorporeal circulation tubing),39 and has been specifically related to patients receiving mechanical ventilation.40 Other high concentration species included several methylcyclosiloxanes, likely emanating from silicon elastomers built in to the catheters. Whilst compounds such as 2-ethyl-1-hexanol and isophorone may be considered exogenous species (the former is used to produce plasticizers whilst the latter is a polymer precursor), the extent to which they are produced in the body is unknown. To our knowledge, only one other study has described validation experiments in which air was sampled from a ventilator circuit in a laboratory.24 Low concentrations of 15 VOCs were found in medical air including cyclohexanone. The researchers did not consider this contamination to have substantially influenced the results of their clinical study investigating breath sampling in mechanically ventilated patients.

In many cases the LoDs in Table 4 were larger for method B than those associated with method A. This is due to the amount of contaminating signal on the chromatograms associated with the use of the suction catheters in method B. Relatively high LoDs for semi-volatile compounds in method A are likely due to interaction with surface materials along the longer sample flow path. Several of the compounds listed in Table 4 have shown to be of diagnostic interest: acetone, isoprene, octane, 3-carene, nonanal, dodecane and tetradecane have been linked to VA-LRTI,3,11–13,41–43 and isoprene has also been linked to muscle activity44 and may thus be altered in mechanically ventilated ICU patients. ARDS has been associated with higher concentrations of octane in exhaled breath (associated with approximately equal LoDs for both methods).45 For many of these compounds, method B showed lower LoDs (Table 4). However, the efficacy of both sampling methods is highly compound-dependent and thus will depend on the chemical species under study.

The non-invasive nature of method A is a significant advantage, allowing it to be implemented in large scale clinical studies (and potentially in clinical practice) more easily. However it should be noted that the creation of a single ‘ideal’ breath sampling method was not a goal of the present study, as different methodologies may require different sampling approaches.46 In our study, we were unable to quantify the potential differences between the ventilators, and as a result of different equipment being used by the different ICUs, the centres were associated with different MDLs. This is an important aspect to consider when conducting multi-centre studies and highlights the importance of a standardized approach to breath sampling both in the critical care unit and across the wider research community.

Author contributions

PvO, CJ, PD and SF conceived and designed the experiments. PvO, CJ and IW performed the experiments. IW analysed the data. PvO, IW and SF wrote the initial manuscript; WA revised the manuscript in response to peer review. PvO, WA, CJ, JBS, TF, LDB, RG, PD and SF approved the final manuscript.

Conflicts of interest

The authors declare no conflict of interest.

Acknowledgements

This study was funded by the NIHR, award number II-LA-0214-20009, and supported by the NIHR Manchester Clinical Research Facility. IW, PMD, TF and SJF are supported by the NIHR Manchester Biomedical Research Centre. We would like to acknowledge the support from Salford Royal Hospital and their Critical Care for the use of the ventilator circuit equipment and decommissioning and regular servicing, as well as the support of the translational Clinical Science laboratories.

References

  1. B. de Lacy Costello, A. Amann, H. Al-Kateb, C. Flynn, W. Filipiak, T. Khalid, D. Osborne and N. M. Ratcliffe, J. Breath Res., 2014, 8, 014001 CrossRef CAS.
  2. A. W. Boots, J. J. B. N. van Berkel, J. W. Dallinga, A. Smolinska, E. F. Wouters and F. J. van Schooten, J. Breath Res., 2012, 6, 027108 CrossRef.
  3. L. D. J. Bos, P. J. Sterk and M. J. Schultz, PLoS Pathog., 2013, 9, e1003311 CrossRef CAS.
  4. M. P. van der Schee, T. Paff, P. Brinkman, W. M. C. van Aalderen, E. G. Haarman and P. J. Sterk, Chest, 2015, 147, 224 CrossRef.
  5. M. Basanta, B. Ibrahim, R. Dockry, D. Douce, M. Morris, D. Singh, A. Woodcock and S. J. Fowler, Respir. Res., 2012, 13, 72 CrossRef CAS.
  6. N. Fens, A. H. Zwinderman, M. P. Van Der Schee, S. B. De Nijs, E. Dijkers, A. C. Roldaan, D. Cheung, E. H. Bel and P. J. Sterk, Am. J. Respir. Crit. Care Med., 2009, 180, 1076–1082 CrossRef CAS.
  7. T. Paff, M. P. van der Schee, J. M. A. Daniels, G. Pals, P. E. Postmus, P. J. Sterk and E. G. Haarman, J. Cystic Fibrosis, 2013, 12, 454–460 CrossRef CAS.
  8. M. Bruins, Z. Rahim, A. Bos, W. W. J. van de Sande, H. P. Endtz and A. van Belkum, Tuberculosis, 2013, 93, 232–238 CrossRef.
  9. P. M. van Oort, P. Povoa, R. Schnabel, P. Dark, A. Artigas, D. Bergmans, T. Felton, L. Coelho, M. J. Schultz, S. J. Fowler and L. D. Bos, J. Breath Res., 2018, 12, 24001 CrossRef.
  10. L. D. J. Bos, M. J. Schultz and P. J. Sterk, BMC Pulm. Med., 2014, 14, 72 CrossRef.
  11. S. J. Fowler, M. Basanta-Sanchez, Y. Xu, R. Goodacre and P. M. Dark, Thorax, 2015, 320–325 CrossRef.
  12. R. Schnabel, R. Fijten, A. Smolinska, J. Dallinga, M.-L. Boumans, E. Stobberingh, A. Boots, P. Roekaerts, D. Bergmans and F. J. van Schooten, Sci. Rep., 2015, 5, 17179 CrossRef CAS.
  13. P. M. P. van Oort, S. De Bruin, H. Weda, H. H. Knobel, M. J. Schultz and L. D. Bos, Int. J. Mol. Sci., 2017, 18, 1–14 Search PubMed.
  14. W. Miekisch, J. K. Schubert and G. F. Noeldge-Schomburg, Clin. Chim. Acta, 2004, 347, 25–39 CrossRef CAS.
  15. W. Filipiak, R. Beer, A. Sponring, A. Filipiak, C. Ager, A. Schiefecker, S. Lanthaler, R. Helbok, M. Nagl, J. Troppmair and A. Amann, J. Breath Res., 2015, 9, 016004 CrossRef.
  16. N. J. W. Rattray, Z. Hamrang, D. K. Trivedi, R. Goodacre and S. J. Fowler, Trends Biotechnol., 2014, 32, 538–548 CrossRef CAS.
  17. W. Filipiak, A. Filipiak, C. Ager, H. Wiesenhofer and A. Amann, J. Breath Res., 2012, 6, 027107 CrossRef.
  18. S. Ghimenti, T. Lomonaco, F. G. Bellagambi, S. Tabucchi, M. Onor, M. G. Trivella, A. Ceccarini, R. Fuoco and F. Di Francesco, J. Breath Res., 2015, 9, 047110 CrossRef CAS.
  19. P. Mochalski, J. King, K. Unterkofler and A. Amann, Analyst, 2013, 138, 1405–1418 RSC.
  20. M. P. van der Schee, N. Fens, P. Brinkman, L. D. Bos, M. D. Angelo, T. M. Nijsen, R. Raabe, H. H. Knobel, T. J. Vink and P. J. Sterk, J. Breath Res., 2013, 7, 16002 CrossRef CAS.
  21. P. Trefz, L. Rösner, D. Hein, J. K. Schubert and W. Miekisch, Anal. Bioanal. Chem., 2013, 405, 3105–3115 CrossRef CAS.
  22. D. Biagini, T. Lomonaco, S. Ghimenti, F. G. Bellagambi, M. Onor, M. C. Scali, V. Barletta, M. Marzilli, P. Salvo, M. G. Trivella, R. Fuoco and F. Di Francesco, J. Breath Res., 2017, 11, 047110 CrossRef CAS.
  23. I. Horváth, P. J. Barnes, S. Loukides, P. J. Sterk, M. Högman, A. C. Olin, A. Amann, B. Antus, E. Baraldi, A. Bikov, A. W. Boots, L. D. Bos, P. Brinkman, C. Bucca, G. E. Carpagnano, M. Corradi, S. Cristescu, J. C. De Jongste, A. T. Dinh-Xuan, E. Dompeling, N. Fens, S. Fowler, J. M. Hohlfeld, O. Holz, Q. Jöbsis, K. Van De Kant, H. H. Knobel, K. Kostikas, L. Lehtimäki, J. O. Lundberg, P. Montuschi, A. Van Muylem, G. Pennazza, P. Reinhold, F. L. M. Ricciardolo, P. Rosias, M. Santonico, M. P. van der Schee, F. J. van Schooten, A. Spanevello, T. Tonia and T. J. Vink, Eur. Respir. J., 2017, 49, 1600965 CrossRef.
  24. L. Bos, M. Schultz and P. Sterk, Respir. Physiol. Neurobiol., 2014, 191, 67–74 CrossRef.
  25. M. Basanta, B. Ibrahim, D. Douce, M. Morris, A. Woodcock and S. J. Fowler, J. Breath Res., 2012, 6, 26002 CrossRef CAS.
  26. L. W. Sumner, A. Amberg, D. Barrett, M. H. Beale, R. Beger, C. A. Daykin, T. W.-M. Fan, O. Fiehn, R. Goodacre, J. L. Griffin, T. Hankemeier, N. Hardy and J. Harnly, Metabolomics, 2007, 3, 211–221 CrossRef CAS.
  27. C. E. Rostad and W. E. Pereira, J. High Resolut. Chromatogr. Chromatogr. Commun., 1986, 9, 328–334 CrossRef CAS.
  28. I. Jerkovic, G. Hegic, Z. Marijanovic and D. Bubalo, Molecules, 2010, 15, 2911–2924 CrossRef CAS.
  29. B. Tirillini, G. Verdelli, F. Paolocci, P. Ciccioli and M. Frattoni, Phytochemistry, 2000, 55, 983–985 CrossRef CAS.
  30. G. Fischer and P. Kusch, LC-GC Int., 1993, 6, 760–763 Search PubMed.
  31. U. Kotowska, M. Zalikowski and V. Isidorov, Environ. Monit. Assess., 2012, 184, 2893–2907 CrossRef CAS.
  32. J. Pino, E. Marquez, C. Quijano and D. Castro, Cienc. Technol. Aliment., 2010, 30, 183–187 CrossRef.
  33. J. Weller and M. Wolf, Beitr. Gerichtl. Med., 1989, 47, 525–532 CAS.
  34. F. Khorasheh, M. Gray and M. Selucky, J. Chromatogr., 1989, 481, 1–16 CrossRef CAS.
  35. A. Kadri, Z. Zarai, I. Chobba, A. Bekir, N. Gharsallah, M. Damak and R. Gdoura, J. Med. Plants Res., 2011, 5, 6502–6508 CAS.
  36. D. Helmig, W. Pollock, J. Greenberg and P. Zimmerman, J. Geophys. Res., 1996, 101, 14697–14710 CrossRef CAS.
  37. J. Spadone, G. Takeoka and R. Liardon, J. Agric. Food Chem., 1990, 38, 226–233 CrossRef CAS.
  38. C. Zhao, Y. Liang, H. Fang and X. Li, J. Chromatogr. A, 2005, 1096, 76–85 CrossRef CAS.
  39. S. Kischkel, W. Miekisch, P. Fuchs and J. K. Schubert, Eur. Respir. J., 2012, 40, 706–713 CrossRef.
  40. J. Julák, E. Stránská, V. Rosová, H. Geppert, P. Španěl and D. Smith, J. Microbiol. Methods, 2006, 65, 76–86 CrossRef.
  41. W. Filipiak, A. Sponring, M. M. Baur, C. Ager, A. Filipiak, H. Wiesenhofer, M. Nagl, J. Troppmair and A. Amann, Microbiology, 2012, 158, 3044–3053 CrossRef CAS.
  42. O. Lawal, H. Muhamadali, W. M. Ahmed, I. R. White, T. M. E. Nijsen, R. Goodacre and S. J. Fowler, J. Breath Res., 2018, 12, 26002 CrossRef.
  43. P. M. van Oort, P. Brinkman, G. Slingers, G. Koppen, A. Maas, J. J. Roelofs, R. Schnabel, D. C. Bergmans, M. Raes, R. Goodacre, S. J. Fowler, M. J. Schultz and L. D. Bos, Am. J. Physiol.: Lung Cell. Mol. Physiol., 2019, 316, L751–L756 CrossRef CAS.
  44. M. Stein, M. Klieber, M. Baumann, K. Unterkofler, G. Teschl, A. Amann, P. Mochalski and J. King, Biochem. Biophys. Res. Commun., 2012, 423, 526–530 CrossRef.
  45. L. D. J. Bos, H. Weda, Y. Wang, H. H. Knobel, T. M. E. Nijsen, T. J. Vink, A. H. Zwinderman, P. J. Sterk and M. J. Schultz, Eur. Respir. J., 2014, 44, 188–197 CrossRef.
  46. J. D. Beauchamp and J. D. Pleil, J. Breath Res., 2013, 7, 1–3 CrossRef.

Footnotes

Iain White was involved in the execution of the experiments and in writing the initial manuscript, but he is unaware of the final manuscript as we are unable to contact him. Therefore he does not take responsibility for its contents.
Both authors contributed equally.

This journal is © The Royal Society of Chemistry 2021
Click here to see how this site uses Cookies. View our privacy policy here.