Hien
Nguyen
ab,
Dilara
Sultanova
b,
Philipp A.
Heizmann
ac,
Severin
Vierrath
abc and
Matthias
Breitwieser
*ab
aElectrochemical Energy Systems, IMTEK–Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
bHahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany. E-mail: Matthias.Breitwieser@Hahn-Schickard.de
cUniversity of Freiburg, Institute and FIT–Freiburg Center for Interactive Materials and Bioinspired Technologies, Georges-Köhler-Allee 105, 79110 Freiburg, Germany
First published on 30th September 2022
Recently, the cell performances of fully hydrocarbon-based fuel cells approached those of cells with perfluorinated ionomers. Most studies used a low catalyst layer ionomer content (∼10 wt%) to enable the highest performance. However, such low ionomer contents can cause a lower cell performance, especially under application-relevant, i.e. reduced humidities (≤50% relative humidity). This work systematically investigates ionomer content gradients in cathode catalyst layers based on hydrocarbon ionomer. A graded ionomer content in the catalyst layer with a higher ionomer content in the vicinity of the membrane (I/C = 0.4, 25% of total layer) and a lower ionomer content (I/C = 0.2, 75% of entire layer) near the gas diffusion layer was found to ensure sufficient proton conductivity without compromising reactant transport. In single-cell tests at hot and dry operation conditions (H2/air, 95 °C and 50% RH), the graded layer enabled both significantly improved current density at relevant cell potentials vs. a monolithic catalyst layer (496 mA cm−2vs. 367 mA cm−2@0.7 V) and slightly increased peak performance (0.76 W cm−2vs. 0.71 W cm−2). Under the given conditions, the performance of the graded layer is similar to that of a Nafion catalyst layer. At 80% RH, the hydrocarbon-graded catalyst layer outperforms the Nafion catalyst layer at high current densities.
Membranes based on sulfonated phenylated polyphenylene ionomer were reported to enable chemical durability compared to Nafion, e.g. 1000 h stability in the accelerated stress test for chemical membrane degradation set by the US Department of Energy.5,6 However, the performance of hydrocarbon-based fuel cells has so far been inferior to that of Nafion-based fuel cells,7 and no performance data under application-relevant conditions has been reported. Recently, more works on fluorine-free membrane electrode assemblies (MEAs) for fuel cells have shown performance approaching PFSA-based MEAs.2,8 Balogun et al.9 have reported a fuel cell based on sulfonated phenylated polyphenylene with performance comparable to Nafion 211 (>1 W cm−2 peak power density and 1.2 A cm−2 at 0.6 V under H2/O2 and fully humidified gas). Our previous study10 demonstrated a fuel cell MEA based on Pemion™ (also based on sulfonated phenylated polyphenylene) with a peak performance that is on par with state-of-the-art PFSA-based MEAs employing short-side-chain materials (>2 W cm−2 peak power density and 2.5 A cm−2 at 0.6 V under H2/O2 and fully humidified gas). Despite the promising high performance, all of these reported MEAs were based on monolithic membranes, i.e. without a mechanical reinforcement layer, making them most likely inapplicable in actual practice. In addition, the balance of material composition versus operation conditions appears even more delicate for fully hydrocarbon-based MEAs than for their typical PFSA-based counterparts. The benchmark performance for fully hydrocarbon-based cathode catalyst layers in our recent work10 and Balogun et al.9 implied remarkably low ionomer-to-carbon (I/C) ratios of only around 0.2 (∼9 wt% ionomer), enabling the highest overall cell performance. These low I/C ratios were considered the best balance between sufficient gas transports through the inherently more gas-tight hydrocarbon ionomer but allowed still good proton conductivity in the porous electrode. As mentioned in our previous work,10 in particular, the sensitivity of hydrocarbon MEAs to the humidity of the gas feed makes them not yet applicable under the targeted operation conditions with low humidification.
Lower gas humidification leads to three main problems, which were also observed in PFSA-based systems: lower ORR kinetics,11,12 higher oxygen transport loss across the ionomer film,13–15 which in turn also affects the ORR and lower proton conductivity, decreasing the catalyst layer utilization.12,16–18 While the former problems cannot be quickly resolved by adjusting the ionomer content, the latter can be optimized by an ionomer gradient in the catalyst layer. Theoretical modelling18,19 and experiments20–22 suggest an inhomogeneous reaction rate within the catalyst layer. Graded catalyst layers, i.e. varying the material composition (e.g. Pt on carbon content, ionomer loading, etc.) in the catalyst layer through-plane direction, are concepts to address this inhomogeneity. Many works on graded catalyst layers report improved performance, particularly at higher current densities.19,21–25 These reports raised our interest in transferring the optimized catalyst layer utilization from the Nafion-based systems to hydrocarbon-based catalyst layers. This work uses grading the catalyst layer to have a high ionomer loading only where needed while reducing the loading to improve gas transport. Thus, using a higher I/C ratio close to the membrane, sufficient proton conductivity and an optimized interface to the membrane should be reached. Using a lower I/C ratio near the GDL ensures good gas transport properties.
The catalyst used in the anode catalyst layer (CL) is Pt/C (45.3 wt% Pt content, Elyst Pt50 0550, Umicore), while that used in the cathode catalyst layer is PtCo/C (45.3 wt% Pt content, Elyst Pt50 0690, Umicore). Cathode catalyst inks are prepared following the same procedure as for the anode. The dry ionomer content in the anode CL is 14 wt%, corresponding to an I/C of 0.3. Cathode catalyst inks with various I/C ratios (0.1 to 0.5) are used to systematically investigate the effect of graded ionomer content in the CL.
Nafion (D2020, DuPont) was used as the binder in the anode and cathode as a reference for the best gradient hydrocarbon-based catalyst layers (Section S3.3, ESI†). The Nafion anode CL contains Pt/C (45.3 wt% Pt content, Elyst Pt50 0550, Umicore) and a dry ionomer content of 33 wt%, as reported in the literature (30–33 wt%).9,21 The Nafion ionomer content used in the PtCo/C cathode CL was varied from 0.3 to 0.9. An ionomer content of 25 wt% (I/C = 0.6) was found to be optimum for the operating conditions (95 °C, 50% and 80% RH, 250 kPaabs, Section 2.2) and, thus, provides the fairest benchmark for the hydrocarbon gradient catalyst layers.
The catalyst inks are deposited on the pristine Pemion™ membranes with an ultrasonic spray system (Sonaer Sono-Cell). Fabricating the membrane electrode assemblies is identical to our previously reported study.10 The aimed Pt loading for the anode is 0.1 mg cm−2, and the total Pt loading for the cathode is 0.4 mg cm−2. The Pt loading was controlled during the spray coating procedure by weighing a thin metal pad of a 2 cm2 area before and after spraying with a microbalance (ME36S, Sartorius AG). The final Pt loading was confirmed by micro X-ray fluorescence spectroscopy (μXRF, Bruker Tornado M4).
In the first part of this work, different ionomer contents within the graded catalyst layers were tested in a proportion of 25% of the total Pt loading in the catalyst layer (0.1 mgPt cm−2) to the membrane (sub-layer I, Fig. 2) and 75% of the total Pt loading (0.3 mgPt cm−2) towards the gas diffusion layer (sub-layer II, Fig. 2). High I/C ratios were chosen for sub-layer I (0.4 or 0.5), and lower I/C ratios (0.2 or 0.1) were kept for sub-layer II. After comparing the two graded cathode catalyst layers (0.4/0.1 vs. 0.4/0.2), the graded cathode catalyst layer with higher I/C to the membrane (0.5/0.2) is also tested.
The second part investigated the proportion of the two sub-layers with the best combination of the I/C ratios. The sub-layer I to sub-layer II ratio was increased from 0% (pure sub-layer II) to 25% of sub-layer I/75% of sub-layer II to 50% of sub-layer I/50% of sub-layer II to 100% of pure sub-layer I.
The mass activities of catalyst layers were investigated under set conditions by the US Department of Energy (DOE);26,27 H2/O2 polarisation curves (0.25 slpm/1 slpm) were measured under 80 °C, 96% RH and 150 kPaabs. The current density was scanned from 0 mA cm−2 to 125 mA cm−2 in 5 mA cm−2 steps for 5 minutes per point (average of last 5 seconds used). The H2/O2 polarisation curves for the mass activity determination were corrected for membrane, contact and electronic resistances, represented by the high-frequency resistances (HFRs). The HFRs were measured simultaneously with the polarization data and were used to evaluate the membrane, interfacial and electronic resistances. HFR spectra were recorded at a frequency of 3200 Hz by the Frequency Resistance Analyzer (FRA) integrated into the fuel cell testing hardware, as described in our earlier work.10 To correct the hydrogen cross-over current densities for the mass activity evaluation, linear sweep voltammetry (LSV) was conducted under H2/N2 (0.2/0.05 l min−1), 80 °C, 96% RH and 150 kPaabs. The Tafel plots were corrected for the ohmic resistance and the hydrogen cross-over current densities ix-over following the approach by Neyerlin et al.18 The mass activity is obtained by dividing the current density corrected with hydrogen cross-over (i + ix-over) at 0.9 VHFR-free and normalized with the cathode Pt-loading of the cell (0.4 mgPt cm−2), which is verified by the micro X-ray fluorescence spectroscopy (μXRF).
The cyclic voltammograms (CVs) were measured under H2/N2, 35 °C, 96% RH and ambient pressure. The potential was swept from 0.05 to 1.0 V versus RHE at a scan rate of 50 mV s−1. The CVs were repeated 8 times to reach saturation. As reported in the literature,7,25 the factor used to calculate the ECSA from the Hupd charge was 210 μC cm−2. Note that the hydrogen underpotential deposition (Hupd) for Pt-alloy only serves as an indicative value for ECSA due to the altered structural and electronic properties of PtCo, which impact the adsorption behaviour of hydrogen.28–30 A LSV under the same conditions as the CV (H2/N2, 35 °C, 95% RH and ambient pressure) was additionally recorded after the CVs to correct possible electrical shorts.
H2/air polarisation curves (0.25 slpm/1 slpm) under commercial applications relevant conditions: H2/air, 95 °C and 250 kPaabs were measured under two different humidities: (a) 50% RH and (b) 80% RH. The current density was scanned from zero to 250 mA cm−2 in 12.5 mA cm−2 increments with a 1 minute hold at each current step.10 Afterwards, the current densities were scanned from 375 mA cm−2 to 6250 mA cm−2 in 125 mA cm−2 increments with a 3-minute hold per current step.10
The proton resistance in the catalyst layers at 50% RH and 96% RH was characterized via AC impedance spectroscopy (Gamry Interface 5000E) recorded in H2/N2 at 0.45 VDC with a root-mean-square perturbation of 1.75 mV between 100 kHz and 0.2 Hz (20 points per decade). The impedance spectroscopy was performed with high flow rates of H2 and N2 (0.5 slpm/0.5 slpm) to avoid possible artefacts caused by mass transport limitations. The cells operated in the same conditions as the mass activity measurements, i.e. 80 °C and 150 kPaabs. The measurements started at low RH to ensure the validity of the proton resistances at lower humidity since the rest water from the previous experiment with higher humidity could remain in the pores of the catalyst layers and positively affect the proton resistances at lower humidity.
For hydrocarbon-based MEAs, similar trends apply: a delicate balance between proton conductivity and oxygen transport is required to achieve optimal performance.9 Due to the higher swelling and the lower gas permeability of typical hydrocarbon ionomers compared to PFSAs, this balance is even more critical for hydrocarbon ionomers. At high humidity (>50% RH), a lower ionomer content (<10 wt%) seems sufficient for sufficient proton conductivity in the catalyst layer due to its relatively high ion exchange capacity (IEC) and high swelling. A higher ionomer content is desired at low humidity for good proton conductivity or CL utilization.18Fig. 1 confirms the higher proton conductivity of a CL with the higher ionomer content (I/C = 0.4 or 18 wt%) compared to that with lower ionomer content (I/C = 0.2 or 9 wt%) at 50% RH.
Fig. 1 Proton resistance of MEAs with different cathode I/C ratios (mono-layers). The H2/N2 impedance spectroscopy is measured at 80 °C, 50% RH and 150 kPaabs. |
However, a high ionomer content has detrimental effects on oxygen diffusion in the CL due to hydrocarbon ionomers’ inherent low gas permeability.7,36 Furthermore, a high ionomer content can cause increased catalyst poisoning by sulfonate37,38 or phenyl groups39–41 or provoke catalyst layer flooding due to the increased CL's hydrophilicity induced by the high ion exchange capacity of the ionomer. All of these factors have undesirable impacts on the overall performance of the fuel cells.
Ionomer gradients have been shown for Nafion catalyst layers to improve performance at high current densities.21,22,24 In these studies,21,22 the optimal ionomer content near the membrane was between 30 and 40 wt% and around 20 wt% near the gas-diffusion media. The improved performance was explained by better proton conductivity at the catalyst layer/membrane interface22 and better mass transport22 or a reduction of flooding problems21 at the catalyst layer/gas diffusion medium interface.
In our previous study,10 the optimal I/C ratio was 0.2 since the best compromise to enable cell operation to high current and power densities. However, limitations have been encountered at application-relevant cell voltages >0.6 V. This encouraged optimizing the MEAs with an I/C higher than 0.2 owing to the higher proton conductivity, especially at low humidity. With a graded catalyst layer, the higher I/C ratio can be partially utilized in the CL without sacrificing performance at high current densities. A schematic illustration of the cathode catalyst layer with a graded ionomer and the proportion variation between high I/C and low I/C are shown in Fig. 2.
Fig. 2 Schematic illustration of the cathode catalyst layer with ionomer content gradient (a) and the proportion variation of sub-layer I (high I/C) and sub-layer II (low I/C) (b). |
The following investigated the optimal graded ionomer content and its proportion in the catalyst layer. The I/C in the sub-layer I (Pt Loading = 0.1 mgPt cm−2) was kept at 0.4, as the proton resistance of the homogeneous CL with this ionomer content was the lowest at 50% RH (Fig. 1).
I/CPEM (0.1 mg cm−2) (25%)/I/CGDL (0.3 mg cm−2) (75%) | Mass activity in A g−1 | Tafel slopes in mV dec−1 | Proton resistances in mOhm cm2 | Cathode CL thickness in μm | Proton resistivity in Ohm cm | ECSA in m2 g−1 | Cathode Pt loading in mg cm−2 |
---|---|---|---|---|---|---|---|
0.2/0.2 | 58 ± 4 | 83 ± 10 | 108 ± 72 | 8.7 ± 0.7 | 124 | 29 ± 2 | 0.42 |
0.4/0.4 | 66 ± 2 | 85 ± 1 | 81 ± 3 | 9.1 ± 0.4 | 89 | 35 ± 2 | 0.43 |
0.4/0.2 | 65 ± 7 | 86 ± 3 | 80 ± 4 | 10.2 ± 0.8 | 78 | 31 ± 2 | 0.43 |
0.4/0.1 | 68 ± 5 | 99 ± 5 | 200 ± 100 | 10.7 ± 0.9 | 228 | 30 ± 1 | 0.46 |
0.5/0.2 | 62 ± 3 | 82 ± 5 | 57 ± 9 | 9.8 ± 0.5 | 58 | 28 ± 1 | 0.45 |
The highest proton resistances are those of the CL, with an I/C of 0.2 and 0.4/0.1. The standard deviation of the proton resistance of the CL with the I/C = 0.4/0.1 is comparably high (>±50%). This deviation could be linked to the too-low ionomer content in the catalyst layer (I/C < 0.2).
The thicknesses of MEAs with graded catalyst layers are similar to those of MEAs with homogeneous CLs (between 9 and 11 μm). The thickness of the CL with the I/C = 0.2 is slightly lower than those of the rest. As a result, the thickness does not significantly affect the trend in proton resistivity (quotient of the CL proton resistance and thickness). The cross-sections of the CLs are shown in Fig. S5a–f (ESI†), along with thickness histograms (Fig. S6a–f, ESI†).
The proton resistivity of the graded CL with the I/C = 0.4/0.1 is substantially higher than the rest (228 Ohm cm), which is expected due to the lower ionomer amount. As the Tafel slopes are extracted from the corrected cell voltage to the high-frequency resistance EHFR-free, they can be greater due to very high proton resistances.18 While the voltage losses to proton resistance are negligible in the Tafel slopes of the other ME, the Tafel slope of the MEA with the 0.4/0.1-graded CL is slightly higher, which is likely affected by the voltage losses due to its proton resistance. The proton resistivity of the cathode I/C = 0.5/0.2 is even lower than that of the CL with pure I/C = 0.4. In addition, the increased ionomer content from 0.2 to 0.4 of only 25% of the total cathode Pt loading in the vicinity of the membrane (sub-layer I) reduces the proton resistivity of the graded ionomer CL to the range of the pure I/C = 0.4 (80–90 Ohm cm). These results imply the importance of proton conductivity in the vicinity of the membrane|CL interface.
The polarization behaviour of the MEAs with the single- and graded layers was characterized under hot and dry conditions relevant for heavy-duty applications and aviation (95 °C, 50% RH and 250 kPaabs). The performance of the 0.4/0.2-graded CL MEA was increased by 35% at 0.7 V compared to the MEAs with homogeneous cathodes I/C (0.2 and 0.4) under the given conditions (Fig. 3).
The higher performance of the graded CL (I/C = 0.4/0.2) compared to that of the CL with I/C = 0.4 is attributed to the lower ionomer content at the GDL side of the CL, which potentially has better oxygen transport. This result is similar to the observations in previous studies with Nafion.21,22 Compared to the MEA with the graded cathode CL of 0.4/0.1, the MEA with the cathode I/C = 0.4/0.2 enables higher performance, most likely attributed to the significantly higher proton conductivity of sub-layer II (Fig. S7, ESI†). Despite the very low proton conductivity in the graded 0.4/0.1 CL, it is remarkable that the cell performance of the MEA with the cathode I/C = 0.4/0.1 is still higher than that with the pure cathode I/C = 0.4, especially at E < 0.6 V (Fig. 3). The result is remarkable, as it might indicate that sufficient oxygen transport, especially at the outer CL (to the GDL), appears to be more critical than the proton conductivity at high current densities.
The performance of the MEA with the graded cathode I/C = 0.4/0.2 is also higher than that with the graded cathode I/C = 0.5/0.2, despite the higher proton resistivity (Table 1). The difference is attributed to the higher I/C of the sub-layer I (PEM), which likely affects oxygen diffusion. The higher performance of the MEA with graded cathode I/C = 0.5/0.2 compared to that with the graded cathode I/C = 0.4/0.1 is probably linked to the lower losses to proton resistivity over the complete CL. The impeded oxygen transport in sub-layer I of the graded cathode I/C = 0.5/0.2 might be less impactful on the overall performance than the lack of proton conductivity in sub-layer II of the cathode I/C = 0.4/0.1 (compared to cathode I/C = 0.4/0.2) (Fig. 3).
I/C | Mass activity in A g−1 | Tafel slopes in mV dec−1 | Proton resistances in mOhm cm2 | Cathode CL thickness in μm | Proton resistivity in Ohm cm | ECSA in m2 g−1 | Cathode Pt loading in mg cm−2 | iRH+/Tafel slope |
---|---|---|---|---|---|---|---|---|
100 % 0.2 | 58 ± 4 | 83 ± 10 | 108 ± 72 | 8.7 ± 0.7 | 124 | 29 ± 2 | 0.42 | 0.03 ± 0.02 |
25 % 0.4 | 65 ± 7 | 86 ± 3 | 80 ± 4 | 10.2 ± 0.8 | 78 | 31 ± 2 | 0.43 | 0.0254 ± 0.0002 |
75 % 0.2 | ||||||||
50 % 0.4 | 61 ± 5 | 90 ± 1 | 129 ± 15 | 10.1 ± 0.8 | 128 | 28 ± 1 | 0.45 | 0.039 ± 0.001 |
50 % 0.2 | ||||||||
100 % 0.4 | 66 ± 2 | 85 ± 1 | 81 ± 3 | 9.1 ± 0.4 | 89 | 35 ± 2 | 0.43 | 0.027 ± 0.002 |
According to Neyerlin et al.,18 the voltage loss due to proton resistances is negligible if the ratio of proton transport resistance over kinetic resistance (iRH+/Tafel slope) is less than 0.15.18 In this study, the ratios iRH+/Tafel slope of all MEAs are below 0.15 (Table 2), assuring negligible voltage losses due to proton resistance and a reasonable low current density (<100 mA cm−2) for the evaluation of the ORR kinetics.18
Similar mass activities (60–70 A g−1), ECSAs (30–35 m2 g−1) and Tafel slopes (80–90 mV dec−1) were observed for all samples, indicating no differences in the kinetics of the four cells at 80 °C, 96% RH and 150 kPaabs. The mass activities of the hydrocarbon-based cells were reported to be generally lower than the typical values of PFSA-based cells (≫70 A g−1),10,42,43 despite applied I/C- and graded ionomer content optimization. As mass transport limitations should be negligible under these conditions (H2/O2 and 150 kPaabs) and low current densities (<100 mA cm−2),44 the lower mass activity could be related to the ORR kinetics. The lower mass activity thus might be linked to the excessive amount of sulfonate groups in the hydrocarbon ionomer poisoning the catalyst.37 The Tafel plots (Fig. S4a, ESI†), the mass-specific current density (Fig. S4b, ESI†) and the cyclic voltammograms (Fig. S2b, ESI†) show no difference in these values.
Fig. 4 shows the proton resistance and resistivity at 80 °C and 50% RH. The proton resistances and resistivity are remarkably reduced by the increasing proportion of I/C = 0.4. This observation emphasizes the importance of proton conductivity of hydrocarbon-based CL next to the membrane at low humidity operations, which can be explained by the higher current distribution next to the membrane at lower humidity.18
Fig. 5 shows the polarisation curves of the four cells and the Nafion reference cell under 95 °C, 50% RH, and 250 kPaabs. The MEAs with CLs with higher I/C (0.4) at the PEM yield higher performance at E > 0.75 V than that with pure cathode I/C = 0.2 (0% of I/C = 0.4). The MEAs with CL with the higher proportion of the I/C = 0.2, i.e. 0% - 25% of I/C = 0.4, in the sub-layer II yield higher performance at E < 0.6 V than the other cells with a lower proportion. The MEA with the cathode I/C = 0.4 (100%) has the lowest performance at E < 0.6 V, most likely due to the limited oxygen transport and flooding.
The performance at 0.7 V of the 25% (I/C = 0.4) graded cathode CL was improved by 35% compared to that with pure cathode I/C = 0.2 and became in line with the Nafion reference under the given conditions. Increasing the I/C = 0.4 proportion of the CL to 50% leads to a decrease in the overall performance. These results show that a higher ionomer content (25% of the CL total Pt loading) in the vicinity of the membrane is beneficial for the low current density region, and it is essential to keep the ionomer content low in the vicinity of the GDL (>50% of the CL total Pt loading) for the high current density region to reduce oxygen resistance. Consequently, the CL with higher amounts of ionomer close to the membrane and less close to the GDL performs best throughout the current density range. The optimal proportion of the low I/C catalyst layer in hydrocarbon cells (75% of the total catalyst layer thickness) is higher than that of Nafion cells (∼30% of the total Nafion catalyst layer thickness).21,22 This result confirms proton conductivity and oxygen permeability differences between hydrocarbon and Nafion ionomers.
At high humidity (80%, Fig. 6), the beneficial properties of the cell with 25% I/C of 0.4 are maintained but less expressed as under 50% RH. The performance of the optimal gradient ionomer cell is in the range of the Nafion cell under low current densities (i < 1.4 A cm−2) and outperforms the Nafion cell at higher current densities (i > 1.4 A cm−2). The current densities at 0.7 V and the peak power densities of the MEAs are shown in the bar chart in Fig. 6c. The performance of the MEA with 25% (I/C = 0.4) graded cathode CL is also higher than the rest at 80% RH, but the improvement compared to, e.g. the MEA with pure I/C = 0.2 was ∼20%, which is not as significant as the improvement at 50% RH (∼35%).
The metrics of a current density of 750 mA cm−2 at 0.7 V and an improved peak performance of 0.95 W cm−2 (95 °C, 80% RH) are a new benchmark for fully hydrocarbon MEAs with commercially available and mechanically reinforced hydrocarbon membranes. The gradient system with 25/75% of I/C 0.4/0.2 enabled the highest peak performance and current density at 0.7 V cell voltage under dry and wet conditions.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d2ma00761d |