Yi
Gao
abc,
Shaofeng
Liang
c,
Shuangliang
Zhao
abde,
Wei
Gao
*abcd,
Zequan
Li
c,
Muqun
Wang
c,
Hong
Li
c,
Xiangning
He
c,
Riyao
Cong
c,
Hailin
Diao
f,
Chuwang
Su
c and
Xiaoying
Xie
abg
aKey Laboratory of Disaster Prevention and Structural Safety of Ministry of Education, Guangxi University, Nanning 530004, Guangxi, China. E-mail: galaxy@gxu.edu.cn
bGuangxi Key Laboratory of Disaster Prevention and Engineering Safety, Guangxi University, Nanning 530004, Guangxi, China
cSchool of Resources, Environment and Materials, Guangxi University, Nanning 530004, Guangxi, China
dGuangxi Engineering and Technology Research Center for High Quality Structural Panels from Biomass Wastes, Nanning 530004, Guangxi, China
eCollege of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, Guangxi, China
fForestry College, Guangxi University, Nanning 530004, Guangxi, China
gSchool of Civil Engineering and Architecture, Guangxi University, Nanning 530004, Guangxi, China
First published on 16th August 2022
The emergence of cooling technology has brought about huge social benefits to society, but it is also accompanied by the serious problem of energy consumption. In countries close to the equator, intense solar radiation is accompanied by unbearable high temperatures and strong ultraviolet radiation. Therefore, we prepared a simple hydrogel with good evaporative cooling, which can work continuously and has good UV absorption, to solve the indoor cooling and UV radiation problems. Polyacrylamide (PAM) in the hydrogel provides a mechanically strong backbone, and polyethylene glycol (PEG) slows water loss and provides the hydrogel with the ability to reflect infrared light. Lithium bromide (LiBr) is a highly efficient water vapor absorbent, which can provide the hydrogel with water regeneration capability. Carbon dots (CDs) can provide excellent UV absorption for hydrogels, and CDs (4.28 kJ kg−1 K−1) have a higher specific heat capacity than water (4.20 kJ kg−1 K−1), which can store more heat for a better indoor cooling effect. The composite hydrogel has a good prospect of application in the windows of residential and high-rise buildings.
At the same time, UV radiation is also a concern, as almost 9% of the Earth's solar energy is in the UV region.10 The risks of exposure to solar ultraviolet radiation (UVR) have long been known. Therefore, the World Health Organization (WHO) has recommended that people living in areas between 30°N and 30°S need year-round sun protection.11 Even indoors, UV radiation can still cause harm to humans through windows, so regulating UV radiation through windows is a good solution.12,13 Carbon dots (CDs) are a new type of carbon nanomaterial with a unique structure that has excellent absorption of UV light.14–18 The application of CDs to windows can well solve the indoor problem of ultraviolet radiation.
Liu reported a layer-by-layer (LBL) structure including a silica aerogel layer and an extra phase change material layer was designed. This structure demonstrates a dual-function regulation performance that regulates and equalizes cold (−30 °C) and hot (70 °C) environments.19 Huang et al. developed a surfactant-assisted ball milling method to prepare an aqueous P(VDF-HFP) coating. The coating was 9.5 °C cooler than room air and 6.2 °C cooler than paint at a solar flux of 950 W m−2 compared with a common titanium dioxide-based paint, further demonstrating the better cooling ability of the aqueous P(VDF-HFP) coating.20 Fang reported the tuneable sunlight scattering behavior of a thermochromic hydrogel. The hydrogel moderator can maintain its own temperature difference within 1.2 °C at ambient air temperature differences exceeding 6 °C.21 In the past, scholars have reported these thermoregulators as a coating or a combination device. In particular, this paper pioneered the introduction of carbon dots with UV absorbing function into hydrogels. This carbon dot hydrogel offers different advantages at the same time.
In this work, we prepare a hydrogel with acrylamide (AM) and polyethylene glycol (PEG) as a simple design of the cooling system, and the hydrogel has good cooling performance. Lithium bromide (LiBr) can provide regeneration capability for the hydrogel and the regeneration time can be shortened with increasing concentration of LiBr. After loading CDs into the hydrogel, the hydrogel has excellent UV shielding ability, which can well solve the UV radiation problem, and CDs have higher specific heat capacity than water, which can help the hydrogel to store more heat and achieve a better indoor cooling effect.
Named | AM (g) | PEG20000 (g) | MBA (g) | I2959 (g) |
---|---|---|---|---|
Hydrogel-0 | 3.0 | 0.0 | 0.15 | 0.090 |
Hydrogel-1 | 2.8 | 0.2 | 0.14 | 0.084 |
Hydrogel-2 | 2.6 | 0.4 | 0.13 | 0.078 |
Hydrogel-3 | 2.4 | 0.6 | 0.12 | 0.072 |
Hydrogel-4 | 2.2 | 0.8 | 0.11 | 0.066 |
Hydrogel-5 | 2.0 | 1.0 | 0.10 | 0.060 |
CDs-hydrogel: after the hydrogel was fully swelled in water, it was placed in an oven for dehydration, and the dehydrated hydrogel was placed in CDs (1 mg mL−1) to swell again, and CDs-hydrogel was obtained.
LiBr-hydrogel: after the hydrogel was completely dehydrated in an oven (50 °C), it was immersed in LiBr. When the hydrogel was completely absorbed and swelled, LiBr-hydrogel was obtained.
CDs/LiBr-hydrogel: LiBr was dissolved in CDs (1 mg mL−1), the completely dehydrated hydrogel was immersed in it, and the hydrogel was left to be completely swollen by absorbing water, and then CDs/LiBr-hydrogel was obtained.
Windows were assembled with PMMA sheets and the hydrogel was placed in the middle like a “sandwich” structure of a smart window. Smart windows were assembled on a simulated building and it was placed outdoors. The building was simulated under both daytime and night-time conditions to test the cooling performance and the ability of the hydrogel to block UV light.
Fig. 2a shows the XPS spectrum of CDs, which shows three representative peaks of C1s (285 eV), N1s (400 eV) and O1s (532 eV). The C1s results in XPS contain three different characteristic peaks (Fig. 2b): CC (284 eV), CO (285 eV), and HO–CO (288 eV); In the N1s results of XPS, there are two different characteristic peaks (Fig. 2c): pyridine nitrogen (398 eV) and pyrrolic nitrogen (399 eV); in the O1s results of XPS, there are three different characteristic peaks (Fig. 2d): C–O–C (530 eV), CO (531 eV), and C–OH (532 eV). The XPS results showed that the CDs contained many reactive functional groups, which was consistent with the FT-IR results.
Due to the existence of CC, it gives CDs the ability to absorb in the near ultraviolet region.27Fig. 3a shows a schematic diagram of the absorption of CDs in the near-UV region. We used UV from 200 to 400 nm for the excitation of CDs, and the CDs responded well to different wavelengths of UV excitation as shown in Fig. 3a. Interestingly, CDs have dual emission under the excitation of ultraviolet light, while most of the CDs reported now have single emission. In addition, Fig. 1d shows that CDs have an absorption response in the blue light region as well. In summary, the CDs prepared from biomass as a precursor can absorb light not only in the near-UV region but also in the visible region. To further apply CDs in practice, we incorporated CDs into hydrogels. CDs-hydrogel was tested outdoors. The UV absorption ability of the hydrogel was tested in both sunny and cloudy weather, and the hydrogel had excellent UV absorption ability and was almost shielded from UV radiation as shown in Fig. 3b–c. The CDs/PEG/PAM hydrogel, as shown in Fig. S4,† can fluoresce blue under UV irradiation, and therefore can be well shielded from UV light. However, considering the factor of cloud obstruction during the test, we choose a 10 mm hydrogel for the next test.
To select the optimal hydrogel, different hydrogels were characterized. As shown in Fig. 4a, the hydrogel without the addition of PEG20000 maintains good transparency, while the addition of PEG20000 makes the hydrogel appear “whitened”, which provides the hydrogel with the ability to reflect NIR light.28,29 In addition, polyethylene glycol has excellent moisturizing properties that slow down the loss of water, as shown in Fig. 4b. It also increases the water content of the hydrogel, which can be seen from Fig. 4c, with the increase of the PEG content. To ensure that the hydrogel can be used in life, the hydrogel needs a certain mechanical strength, but polyethylene glycol is a long-chain polymer, which makes the hydrogel lose some of its rigidity as shown in Fig. S5.† Compared to hydrogel-0, the mechanical strength of other hydrogels has decreased, as shown in Fig. 4d. However, both hydrogel-1 and hydrogel-2 were able to maintain their morphology well without deformation under the pressure of 500 g weight, as shown in Fig. S6.† As shown in Fig. S7,† hydrogel-0 and -1 both appeared to be broken after dehydration, while the other hydrogels could still keep their shapes intact after dehydration. The PAM hydrogel is too rigid and will break after complete dehydration, but the softened hydrogel can still maintain the intact form under dehydration. The addition of PEG endows the hydrogel with the ability to reflect light, and it is known from Fig. 4e and f that the reflection of near-infrared light is greater with increasing PEG content. The reflection of near-infrared light can be synergistically cooled down with cooling evaporation.
LiBr is an efficient water vapor absorber and air humidity regulator, loaded into the hydrogel to give the hydrogel the ability to regenerate after water loss.30 The hydrogel composed of PAM and PEG, which distributes LiBr in the hydrogel, can effectively maintain the water content of the hydrogel, as shown in Fig. 5a–c. With the synergistic effect of PEG and LiBr, the hydrogel is less susceptible to water loss, which is essential for the cooling system. In addition, the hydrogel needs to have good regeneration ability. We placed the hydrogel outdoors and after two hours of exposure to sunlight, the hydrogel lost nearly 10% of its weight. Then, the hydrogel was placed in a room and the hydrogel was regenerated by absorbing water from the air after the temperature dropped, and after 10 hours, the hydrogel was completely regenerated, as shown in Fig. 5d. However, an excessively long regeneration time is clearly inappropriate. Increasing the concentration of LiBr can accelerate the regeneration of the hydrogel and thus shorten the regeneration time as shown in Fig. 5e. Fig. 5f and g show the time for a hydrogel to lose 0.1 g of water at 55 °C and then regenerate at room temperature. The regeneration time decreases with increasing ambient temperature and humidity, which is attributed to high humidity and ambient temperature. High humidity is necessary to accelerate the regeneration time, while an increase in temperature accelerates the movement of molecules and thus the absorption of water from the environment by the hydrogel.
As shown in Fig. 6a, we assembled the windows using PMMA sheets and placed the hydrogel in the middle, like a “sandwich” structure. One side of the PMMA board with holes facilitates the evaporation of water and takes away heat. At the same time, it can also effectively protect the hydrogel and play a self-cleaning role. Fig. 6b shows the diurnal working principle of the smart window. During the daytime, the hydrogel is exposed to the radiation of the sun, and the evaporated water escapes through the hole, which acts as evaporative cooling. At night, the moisture in the air is absorbed by the hydrogel through the holes for regeneration. As shown in Fig. S8,† the smart windows were assembled, and indoor simulation tests and outdoor tests were conducted to verify the cooling performance of the hydrogel. Fig. 6c shows the indoor test results of the hydrogel. From the results, the hydrogel can effectively have a cooling effect, and the PAM and PAM/PEG decreased the temperature by 5.5 and 9.5 °C respectively after 60 min of heating by a light source. Due to the presence of a large number of hydrogen bonds in water, water has a high specific heat capacity (Cp = 4.2 kJ kg−1 K−1), which can effectively store heat.31,32 As shown in Fig. S9,† the temperature of the hydrogel after heating for 60 min is as high as 56.2 °C. The outdoor test results are shown in Fig. 6d. The temperature of the three groups of test samples peaked after 3 h of sunlight irradiation, and the temperature of PAM and PAM/PEG decreased by 4.3 and 5.6 °C, respectively. The test results show that the hydrogel has excellent cooling performance, and PAM/PEG shows better cooling performance than PAM.
Fig. 6 (a) Smart window assembly diagram. (b) Working principle diagram of the smart window during day and night. (c) Smart window indoor testing. (d) Smart window outdoor testing. |
Fig. 7a shows the schematic structure of the composite hydrogel. CDs and LiBr are distributed in the hydrogel, CDs can efficiently absorb UV light, LiBr provides regeneration ability for the hydrogel,33 and PEG and PAM can lock the water. In Fig. S10,† it is obvious that CDs distribute evenly in the hydrogel network. PAM and PVA provide the skeleton structure of the hydrogel, and the carbon quantum dots are wrapped inside. The hydrogel structure of the double network has good mechanical properties and enough space, as shown in Fig. 1e, because of the presence of CO in the structure of CDs. In Fig. 7b, the specific heat capacity (4.28 kJ kg−1 K−1) of the CDs/PAM/PEG hydrogel is higher than that of water (4.20 kJ kg−1 K−1),34 which means that the thermal storage capacity of the hydrogel is enhanced. The UV absorbing ability of the hydrogel was tested outdoors, and the hydrogel can effectively solve the problem of UV radiation indoors on both sunny and cloudy days as shown in Fig. 7c. The composite hydrogel was tested for outdoor cooling performance, and the results are shown in Fig. 7d. Compared with the blank group, the composite hydrogel decreased by 6.1 °C at most. Compared with the hydrogel without CDs, the composite hydrogel decreased the temperature by 0.5 °C. The results showed that the cooling performance of the composite hydrogel was better. The good UV absorption ability and cooling evaporation performance can make the composite hydrogel have good application prospects. Applying the composite hydrogel to offices, residences, and buildings with floor-to-ceiling windows (cafes) can block ultraviolet rays and reduce cooling energy consumption.
Fig. 7 (a) Schematic structure of CDs/LiBr-hydrogel. (b) Specific heat capacity of CDs and water. (c) UV absorption (sunny & cloudy). (d) CDs/PAM/PEG hydrogel outdoor testing and comparison. |