Xumei Wanga,
Qi Suna,
Xinjian Song*a,
Yan Wanga and
Wei Hu*b
aHubei Key Laboratory of Biological Resources Protection and Utilization, School of Chemical and Environmental Engineering, Hubei Minzu University, Enshi, 445000, China. E-mail: whxjsong@163.com
bCollege of Bioresources and Materials Engineering, Shaanxi University of Science & Technology, Xi'an, 710021, China. E-mail: huwchem@sust.edu.cn
First published on 20th January 2022
In recent years, reflecting the degree of cellular inflammation through in situ monitoring of nitric oxide using fluorescence sensing has received much attention due to many merits such as non-invasiveness and easy operation. In particular, two-photon excitation microscopy can significantly improve the imaging resolution and visualization time. In the meantime, a ratiometric-based nitric oxide fluorescent sensor can avoid the interference of many factors, including light source intensity, solvent scattering degree, solvent color, solvent viscosity, probe distribution, and instrument performance, and improve the accuracy of the result. However, the mutual interference of two emission peaks is still an issue restricting the development of this field. In this work, the Rh-NO-F dye obtained by modifying the rhodol dye with benzothiazole exhibited excited state intramolecular proton transfer (ESIPT) in the closed ring state. In the open ring state, however, the emission wavelength can be significantly red-shifted by increasing the degree of dye conjugation. By introducing o-phenylenediamine, the recognition domain of NO, we successfully designed and synthesized a ratiometric two-photon NO fluorescent probe, Rh-NO-P, which showed a 154 nm increase in the maximum emission wavelength before and after the response and almost no interference between the two emission peaks. Confocal imaging showed that the probe could achieve in situ detection of exogenous NO fluctuations in cells. The probe was also successfully applied to detect the changes in NO content during wound healing in mice.
Currently, fluorescence imaging has provided powerful assistance for real-time and in situ detection of NO distribution and concentration fluctuations in living organisms due to its advantages of simple operation, visualization, high sensitivity, and high spatial and temporal resolution. A large number of NO fluorescent probes have been developed, which mainly include organic fluorescent probes and metal–ligand complex probes.11–15 However, due to the limitation of the response mechanism, most NO probes exhibit the characteristics of a turn-on or turn-off type, and ratiometric fluorescent probes are rarely reported.16–20 It is known that ratiometric fluorescent probes can correct the two emission peaks by themselves to eliminate the effects of environmental factors on the experimental results (including artificial interference caused by the environmental change of the probe, probe concentration, and excitation intensity) and increase the effective range of the fluorescence measurement.21–26 Based on FRET scaffold carrying BODIPY and TMR fluorescent beams, Xiao's group reported a ratiometric fluorescent probe with high sensitivity and selectivity to NO, which was the pioneering work in this field.27 After that, NO sensitivity ratiometric fluorescent probes have been continuously reported.28 However, the crosstalk interference between the two emission peaks seriously affects the accuracy and resolution of the results. Therefore, expanding the distance while reducing the interference between the two emission peaks and effectively improving the accuracy and resolution of ratiometric fluorescent probes remains one of the scientific problems requiring urgent solutions.
The current strategies for constructing ratiometric fluorescent probes mainly include the charge transfer mechanism (ICT, including intramolecular electron transfer and twisted intramolecular charge transfer),29 excited state intramolecular proton transfer (ESIPT), and energy transfer (including fluorescence resonance energy transfer and through-bond energy transfer).30,31 The charge transfer mechanism and excited state proton transfer are based on changing the energy difference between the highest occupied molecular orbital (HOMO) and the lowest unoccupied molecular orbital (LUMO) of the molecule, which could lead to synchronous changes in the emission wavelength and the absorption wavelength before and after the response. The complete separation of the two emission peaks requires two different excitation wavelengths, which will result in more cumbersome detection procedures and unguaranteed accuracy. In recent years, ratiometric fluorescent probes constructed based on energy transfer, especially through-bond energy transfer, have been reported by our group to have single-wavelength excitation and dual-emission peaks baseline separation. However, the large molecular weight and high fat solubility limit the probes' high sensitivity real-time target monitoring in living organisms.
Our group previously reported a fluorescent dye Rh-NO-F based on the rhodol dye, which exhibited excellent photophysical properties of the rhodol dye, such as high fluorescence quantum yield, large molar absorption coefficient, and good light stability, but also extended the π-conjugated system of the rhodol fluorescent dye through the introduction of the strong electron-withdrawing group 2-(2-hydroxyphenyl)-benzothiazole (HBT), thereby ensuring that the emission wavelength reached the near-infrared region.32–34 In this work, Rh-NO-F was modified with o-phenylenediamine (Rh-NO-P), a typical NO recognition domain, to close its ring, thereby quenching the fluorescence emission of the rhodol dye. Thus, the free state hydroxyl group can undergo an excited state intramolecular proton transfer with HBT to emit shorter-wavelength fluorescence. What's more, regardless of whether excitation in one-photon mode (380 nm) or two-photon mode (800 nm), two non-interfering fluorescence emission peaks (with emission wavelengths of 457 nm and 611 nm) appeared before and after the reaction between Rh-NO-P and NO, which had a distance of 154 nm. In vitro experiments showed that Rh-NO-P had a highly sensitive response to NO with a detection limit of 51.3 nM, and its ratio intensity reached the maximum at 20 s, which was enhanced approximately 110.9-fold. In the end, we used NO as an inflammation marker and successfully tracked the fluctuations in the degree of cellular inflammation during wound healing in mice.
Based on the above analysis, this study first detected the photophysical properties of the fluorophore Rh-NO-F in different solvents. As shown in Fig. S4 and Table S1,† Rh-NO-F has two obvious absorption peaks in different solvents at 350 nm and 560 nm, and the maximum emission peak appears at 580–590 nm. The polarity of the solvent has a negligible influence on the emission wavelength and quantum yield of Rh-NO-F. Meanwhile, Rh-NO-F shows the highest quantum yield in dimethyl sulfoxide (DMSO, Φ = 0.61, rhodamine B as a reference). Therefore, in all the following experiments, we used PBS buffer containing DMSO as the measurement conditions. Next, the solubility of Rh-NO-P was determined under the conditions of PBS buffer (10 mM, pH = 7.4, containing 10% DMSO). The results are shown in Fig. S5.† The absorption spectroscopy shows that when the concentration of Rh-NO-P reaches 25 μM, the intensity does not reach the plateau, indicating that the probe still has good solubility and therefore it can be used for detection in subsequent experiments. Then, the absorption and emission spectra before and after the reaction of Rh-NO-P with NO were investigated. It can be seen from Fig. 1c and d that Rh-NO-P itself has an obvious absorption peak at 360 nm, and the fluorescence emission occurs at 457 nm. However, after the reaction with NO, the absorbance at 360 nm increases slightly, and a new peak occurs at 560 nm. In addition, the fluorescence emission peak moves from 457 nm to 611 nm after the response. The possible reason for this movement is that the probe reacts with NO to produce the triazole derivative intermediate 1; then benzotriazole is hydrolyzed and falls off to form the fluorophore Rh-NO-F; the ESIPT effect disappears, and the opening of the rhodamine ring occurs (shown in Fig. 1b). In order to verify the speculation of the response mechanism of probe Rh-NO-P and NO, HR-MS was applied (see the ESI, Fig. S6†). It can be seen that the molecular ion peaks of Rh-NO-P, 1 and Rh-NO-F are 611.2089, 622.1831, and 521.1452, respectively, which proves the rationality of the speculation. In order to evaluate whether the probe Rh-NO-P can be used for two-photon confocal imaging, this work investigated the relationship between two-photon emission intensity and excitation optical power. The results indicated that the slopes of the square of the two-photon excitation optical power versus the two-photon fluorescence intensity of Rh-NO-P and Rh-NO-F are close to 2.0 (2.38 and 2.06, respectively), indicating that the two-photon absorption process can occur in Rh-NO-P before and after the reaction with NO (as shown in Fig. 1e and f). We also investigated the quantum yield and two-photon activity cross-section of Rh-NO-P before and after the reaction with NO (see the ESI, Fig. S7 and Table S2†). It can be seen that the quantum yields before and after the reaction between Rh-NO-P and NO are 0.41 and 0.56, respectively, and the two-photon maximum activity cross-section at 800 nm reaches 49.5 GM and 189.8 GM, respectively, indicating that the probe can be applied for two-photon confocal imaging.
Based on the above findings, this study explored the response of the probe Rh-NO-P to the concentration of NO. The absorption spectra show that with the increase of the concentration of NO, the absorption peak at 350 nm is slightly increased while the absorption peak at 560 nm is significantly enhanced (shown in Fig. 2a). It can also be seen that the emission peak intensity at 611 nm gradually increases. Meanwhile, the fluorescence intensity at 457 nm gradually decreases (as shown in Fig. 2b), and the distance between the two emission peaks reaches 154 nm, indicating that the probe Rh-NO-P has a significant ratio response to NO. Besides, the two emission peaks have almost none of the crosstalk, thereby increasing the accuracy and resolution of the detection. We also investigated the relationship curve between the fluorescence intensity ratio (I611/I457) and NO concentration. As shown in Fig. 2c and d, when the NO concentration is lower than 12 μM, the I611/I457 and NO concentration have a good linear relationship, and then the reaction reaches a plateau. The correlation coefficient R2 = 0.994, indicating that the probe can achieve accurate detection of NO. More importantly, the detection limit of this method can be calculated as 51.3 nM based on LOD = 3σ/k. In addition, the reaction between Rh-NO-P and NO gradually reached a plateau after 20 s (red line in Fig. 2e), indicating that the probe Rh-NO-P can quickly respond to NO. In the absence of NO, no changes in I611/I457 were observed in the reaction solution, indicating that the probe was stable in the system. The changes of I611/I457 with the pH value of the solution before (green line) and after (red line) the reaction between the probe Rh-NO-P and NO (see the ESI, Fig. S8†). It can be seen that the I611/I457 value of the probe Rh-NO-P in PBS solutions with different pH values (2–11) is basically unchanged, indicating that its fluorescence intensity before and after the reaction is basically not affected by the pH value. Finally, we investigated the selectivity of probe Rh-NO-P for NO. Interferents including Cys, Hcy, GSH, H2O2, ˙OH, O2˙−, HOCl, NO2−, ONOO−, NO2, SO2, H2S, H2Sn, Fe3+, Ca2+, Mg2+, Zn2+, and Cu2+ were selected, and the fluorescence response of the probe was examined. It was found that I611/I457 could not be significantly enhanced by interferents; however, it was enhanced after the addition of NO (Fig. 2f). These results indicate that the probe Rh-NO-P is highly selective for NO.
Then, the confocal imaging of Rh-NO-P for exogenous NO in BV-2 cells was conducted to explore the application of Rh-NO-P in living cells. The results are shown in Fig. 3. In two-photon confocal imaging, BV-2 cells were incubated for 30 min with NOC-9 with different concentrations (0, 10, 20, 40 μM) and then were incubated for 20 min with 10 μM Rh-NO-P. As the concentration of NOC-9 increased, the fluorescence of the blue channel (410–530 nm) of Rh-NO-P decreased continuously, while the fluorescence of the red channel (580–650 nm) increased continuously. After the addition of 40 μM NOC-9 and aminoguanidine AG (0.5 mM, NO scavenger), the fluorescence of the red channel disappeared, and the fluorescence of the blue channel was restored. The one-photon fluorescence imaging results are consistent with the two-photon fluorescence imaging results (Fig. S11†). These results indicate that the probe Rh-NO-P was able to detect exogenous NO with high sensitivity in either one-photon mode or two-photon mode.
Subsequently, in this work, we used LPS/IFN-γ to stimulate the inflammatory response of cells. The overexpression of inducible nitric oxide synthase (iNOS) during the inflammatory response of cells resulted in the increase of NO levels. The two-photon fluorescence imaging results are shown in Fig. 4a and b. After the cells were treated with LPS and IFN-γ, the fluorescence intensity of the red channel was significantly increased compared with that of the Sham group, while the fluorescence intensity of the blue channel was almost negligible. Inflammation inhibitor (NS-398), oxidative stress inhibitor (Apocynin, APO), and NOX-2 (ROS synthesis protein) gene silencing (NOX-2KD) were applied, respectively. The results showed that NO level was dramatically decreased, indicating that during the LPS/IFN-γ stimulation, inflammation was caused by oxidative stress of cells. Besides, the ratio signal of the negative control group was significantly higher than that of the NOX-2KD group. The one-photon fluorescence imaging results are consistent with the two-photon fluorescence imaging results (Fig. S12†). The above experiments demonstrated that NOX-2 protein could regulate oxidative stress of cells and cause inflammation, whether in one-photon mode or two-photon mode. ELISA also demonstrated the accuracy of our view (Fig. 4c–e). The levels of the inflammatory factors TNF-α and IL-1β, and hydrogen peroxide (H2O2, a marker of cellular oxidative stress) had the same changing trend with the ratio signals, indicating that inhibiting oxidative stress could significantly suppress cellular inflammation. More importantly, the CCK-8 experiment showed that oxidative stress inhibitors and inflammation inhibitors could both alleviate cell death induced by cell inflammation. This conclusion provides a theoretical basis for wound healing in mice (shown in Fig. 4f).
Based on the above findings, fluorescence imaging of inflammatory wound tissue of Rh-NO-P was investigated (Fig. 5). The mice were divided into three groups: the first group is the control group; the right feet of the mice in the second group were cut; the right feet of the mice in the third group were also cut, and the mice in the third group were given a subcutaneous injection of NS-398 through the inner thigh. 12 h later, the three groups of mice were injected subcutaneously with Rh-NO-P (200 μL, 100 μM) through the inner thighs. 1 h later, the wound biopsies of the three groups were imaged. The results were similar to those of the cell model. The red channel fluorescence intensity of the skin tissue of mice in the wound group was significantly increased compared with that in the normal group, the blue channel fluorescence was negligible, and the ratio signal was significantly increased. The ratio signal of the NS-398 pre-injection group was significantly reduced compared with that of the wound group, indicating that the wound can induce inflammation in mice (Fig. 5a and b). H&E staining light microscopy showed that the mice in the control group had clear skin tissue structure and normal cell morphology while the mice in the wound group showed significant abnormalities in the skin tissue structure, with a significant increase in nuclear pyknosis. However, after adding NS-398, the tissue structure of mice was less damaged and recovered from time to time. The nuclear pyknosis was reduced, and inflammatory cells were reduced. Additionally, the expression of IL-6 by immunohistochemical staining analysis and ROS expression by DHE staining were consistent with the cellular results (Fig. 5c–e). The above experimental results show that the inflammation in mice is attributed to the wound, and NS-398 can protect the mice from skin damage caused by the inflammatory response.
Footnote |
† Electronic supplementary information (ESI) available: Experimental details and characterization of Rh-NO-F and Rh-NO-P supplementary spectral results. See DOI: 10.1039/d1ra08426g |
This journal is © The Royal Society of Chemistry 2022 |