Krishnadas Narayanan Nampoothiri‡
a,
Niladri Sekhar Satpathia and
Ashis Kumar Sen*ab
aFluid Systems Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai-600036, India. E-mail: ashis@iitm.ac.in
bMicro Nano Bio Fluidics Group, Indian Institute of Technology Madras, Chennai-600036, India
First published on 17th August 2022
Fluid manipulation using surface acoustic waves (SAW) has been utilized as a promising technique in the field of microfluidics due to its numerous advantages, over other active techniques, such as low power requirement, facile fabrication methods, and non-invasive nature. Even though SAW-based generation of micron-sized droplets through atomization has been studied, the role of substrate wettability on the characteristics of the transferred droplets has not been explored to date. Here, we study the generation and effective transfer of micron-sized droplets using SAW onto wettable substrates whose water contact angles vary from 5° to 145°. The characteristics of transferred droplets after impacting the wettable substrates are characterized in terms of the contact line diameter and polydispersity index. A theoretical model is formulated to predict the initial average size of the transferred droplets on the wettable substrates of different contact angles. The variation of polydispersity and number density with contact angle is explained by considering droplet coalescence and bouncing. The relevance of the technique in biological assays is demonstrated by transferring droplets of streptavidin protein samples onto a substrate.
SAWs are defined as mechanical vibrations of nanometric amplitudes that propagate on the surface of a piezoelectric substrate.23 Upon applying an AC electrical signal to interdigitated electrodes (IDTs), mechanical traveling waves are formed on the surface of the piezoelectric substrate as a consequence of the inverse piezoelectric effect. When SAWs encounter a liquid, leaky SAWs are introduced into the bulk of the liquid at the Rayleigh angle.22,32 When sufficient power is applied, strong capillary waves at the air-droplet interface overcome the capillary stress and form micron-sized satellite droplets.28,33–35 The atomized droplet sizes are typically measured during their flight using time of flight experiments28,36 and using this mechanism, droplets of size in the range of 1 to 100 μm were generated in a rapid and controlled manner.24,37 The ease of mass-fabrication of SAW devices provides SAW atomizers38,39 with an edge over ultrasonic atomizers.40,41
From the application perspective, SAW-based atomization has been reported as an effective technique for extraction of bioreagents,26 transfer of analytes into a mass spectrometer for peptide detection,35 drug delivery,42–44 and the production of insulin liquid aerosols and solid protein nanoparticles.39 Qi et al.26 demonstrated the usage of paper strips for SAW atomization and extracted protein molecules and yeast cells (∼5 μm) from narrow paper strips. Sun et al.35 presented an integrated SAW-based chip that could control the nebulization rate of the non-volatile analytes during atomization. Huang et al.42 utilized the SAW-based nebulization for asthma treatment. Alhasan et al.43 utilized this SAW atomization platform for efficient pulmonary stem cell delivery. Rajapaksa et al.44 demonstrated the delivery of a pDNA vaccine in a large animal model using SAW based hand-held nebulizer. Owing to the scaled-down device and absence of nozzles, the SAW-based atomization technique can be utilized for cooling electronic devices.45 Huang et al.46 investigated the effect of acoustothermal heating and measured the temperature distribution of liquid atomization during SAW actuation. To avoid the effect of acoustothermal heating in efficient transfer of proteins and cells, literature suggests the usage of low SAW powers (<4 W).23,47 Even though the transport of droplet-encapsulated bioreagents has been demonstrated in the literature, the effect of substrate wettability on the characteristics of these transferred droplets has not been investigated. This study is critical for the transfer of monodisperse droplets which has relevance in various applications such as cosmetics,48 food,49 and chemical industries.50 These droplets can also serve as microvessels for carrying out various bio-detection techniques.51,52
In the present work, we have investigated the characteristics of the transferred droplets after impacting onto various wettable substrates. These droplets are generated using SAW technique on LiNbO3 substrate and the source liquid used is in the form of a thin liquid film which is proven to offer a higher atomization rate as compared with that obtained using microliter volume droplets.28,32,53 For such a study, surfaces of different wettability with water contact angles (WCA) in the range of 5° to 145° are prepared using a glass coverslip as the base substrate. The transferred droplets on the different wettable substrates are imaged to obtain the droplet characteristics such as the size distribution and the polydispersity index. A theoretical model is presented that predicts the average initial size of the transferred droplets on the wettable substrates. During these experiments, the wettability of the LiNbO3 substrate is unaltered since literature54 suggests that as the wettability of the LiNbO3 substrate is changed to hydrophobic/superhydrophobic the area fraction through which the surface acoustic waves leak into the droplet decreases and there will be no effect of surface acoustic waves. Finally, the potential application of the technique is demonstrated by transferring streptavidin protein molecules.
Fig. 1 Schematic diagram of the experimental setup depicting the generation of liquid film, SAW-based droplet atomization, and transfer of atomized droplets to a substrate. |
A piece of polyester cellulose lint-free paper is used to wick the liquid from a reservoir through capillary action and to maintain a continuous liquid film front exposed to the SAWs.32 The surface of the liquid film undergoes capillary instability resulting in the ejection of small droplets that are deposited on surfaces of different wettability with a glass coverslip as the substrate, as shown in Fig. 1. The side view of the liquid film is captured using a high-speed camera (Photron Fastcam Mini AX200).
The temperatures of the substrates were measured using a thermal IR camera (A6701, FLIR). The IR camera is calibrated against an external thermometer by measuring the temperature of a water bath, which is heated using a hot plate.
Streptavidin (biotin-binding proteins) covalently attached to a fluorescent label, Qdot™ 625 Streptavidin conjugate, is transferred from the liquid film to the substrate. Optiprep™ (Sigma-Aldrich) is used as the density gradient medium to ensure Streptavidin particles remain neutrally buoyant.
The images of the transferred droplets and the biotin-binding proteins are captured using a 60× objective lens attached to an inverted fluorescent microscope (IX71, Olympus) in combination with a high-speed camera (SA5, Photron) and a fluorescence attachment (Olympus U-HGLGPS). The size distribution of the transferred droplets are analyzed using ImageJ software.57
Microscopic coverslips (Blue Star, India) of thickness 0.17 mm are used as the substrates for transferring the atomized droplets (Fig. 1). The water contact angle of the coverslip substrate (WCA) is varied in the range of 5° to 145°, as shown in Fig. 2, by using the protocols described below. The various contact angles are measured using a Goniometer and Drop Shape Analyzer (DSA25, KRÜSS GmbH). Each measurement is repeated at least thrice on multiple substrates having the same wettability to ensure repeatability and reproducibility.
PDMS base and curing agent at 10:1 ratio are thoroughly mixed and the mixture is degassed in a desiccator to remove air bubbles. The coverslip substrate is washed with isopropyl alcohol in an ultrasonicator and dried by spraying high-pressure N2 gas. The PDMS mixture is spin-coated on a glass coverslip at 4000 rpm for 50 s and cured at 140 °C for 1 h resulting in a uniformly coated and cured PDMS layer. The PDMS surface is then exposed to oxygen plasma (PDC – 002, Harrick Plasma, U.S.A.) at 30 W for 90 s,58 and the WCA of the PDMS surface immediately after the exposure is measured to be 5° ± 0.2° (Fig. 2a). In addition to the wettability of the substrate, the surface roughness can also have an effect on the droplet distribution. PDMS substrate will have nanometric roughness, as reported in another study from our group.59 But here we keep the surface roughness fixed and only study the effect of wettability. The variation of the wettability of a plasma exposed PDMS surface with time has been investigated elsewhere,60 which is attributed to the adsorption of the –OH bonds into the PDMS layer.60 From our measurements, we found the WCA of PDMS surfaces to be 18° ± 0.1° after 8 h (Fig. 2b) and 37° ± 0.3° after 24 h (Fig. 2c). The WCA of the cleaned coverslip and PDMS surface without plasma exposure after curing for 140 °C for 1 h is measured to be 60° ± 0.2° and 84° ± 0.3°, respectively (Fig. 2d and e respectively), which are consistent with values reported in the literature.61,62
The obtained PDMS surface is considered rigid since the elastocapillary number length63,64 (γ/E) , where γ is the liquid surface tension and E is the Young's modulus of PDMS,65 is considered to be low (≈10−8 m). To achieve hydrophobic surface, the spin-coated PDMS layer is cured at 180 °C for 90 min,66 and the WCA is measured to be 110° ± 0.3° (Fig. 2f). To obtain a superhydrophobic surface, the glass coverslip is coated with 30 nm diameter silica nanoparticles (Glaco Mirror coat, Soft 99, Japan) and heated at 110 °C for 1 h to reinforce the coating.55 The coating offers a surface having micro and nanoscale dimensions and the WCA is measured to be 145° ± 0.2° (Fig. 2g). The substrate has very low (∼±2°) contact angle hysteresis which ensures the minimal effect of the same in spreading and retraction of the droplet upon impact. Since experiments with each of the wettable surfaces are completed within 15 min during which the WCA variation is insignificant,60 the effect of the dynamic wettability change on the droplet characteristics can be safely neglected. The different protocols used to achieve different WCAs are summarized in Table 1.
Substrate surface | Curing condition | Plasma exposure time | Waiting time | WCA |
---|---|---|---|---|
Glass coverslip | Not applicable | Not applicable | Not applicable | 60° ± 0.2° |
Spin coated PDMS | 140 °C, 1 h | 84° ± 0.3° | ||
Spin coated PDMS | 180 °C, 90 min | 110° ± 0.3° | ||
Silica nanoparticle coating | 110 °C, 1 h | 145° ± 0.2° | ||
Plasma exposed PDMS | Not applicable | 30 W for one and half min | Not applicable | 5° ± 0.2° |
8 h | 18° ± 0.1° | |||
24 h | 37° ± 0.3° |
Since the experiments are performed for a duration of 5 s, there might be the effect of acoustothermal heating which can produce heating effect on the atomized droplets. Thus, the temperature distribution of the substrate (with and without thin liquid film) is measured using a thermal camera. The emissivities of LiNbO3 and water are given as 0.71 (ref. 67) and 0.96.68 Fig. S1a† shows the thermal IR image of the substrate (with liquid thin film) when SAW is actuated for 10 s. A region of interest (ROI) is created and the average temperature of ROI during SAW actuation is measured. Fig. S1b† provides information about the average temperature rise for the dry substrate and for the thin liquid film for the same ROI. The maximum temperature rise for time t = 5 s is observed to be 2.25 °C and 0.25 °C for the wet and dry substrates respectively. Thus, the effect of acoustothermal heating can be negated during the experiments.
Within 1.0 ms of SAW actuation, droplets are observed on the coverslip substrate indicating that the timescale of instability and subsequent atomization is smaller than 1.0 ms and hence the processes occur quite rapidly.27,37 The experimental images of the droplets collected on the various wettable surfaces at t = 0 s and t = 5 s are presented in Fig. 3b and c and S2.† Here, t = 0 s denotes the time instant at which the droplets were first observed on the coverslip substrate, and t = 5 s represents the time instant just after 5 s. When the droplets impact the wettable coverslip substrates, depending on the WCA and the time elapsed, the contact line diameter of the drops Dm and the droplet number density (Nd) on the coverslip will be different.
The size distribution of contact line diameters of the droplets at t = 0 s and t = 5 s on different substrates having different WCA are presented in Fig. 4a and b and S3.† From the captured images, ROI is chosen which could accommodate the maximum number of droplets. For consistency the coordinates of the ROI is kept constant for all images. The edges of the transferred droplets are detected using ImageJ through edge detection process.
Fig. 4 Droplet size distributions at (a) t = 0 s and (b) t = 5 s on surfaces having different WCA (a-i and b-i) 5° (a-ii and b-ii) 37° (a-iii and b-iii) 60° (a-iv and b-iv) 145°. |
It is observed that for smaller WCA (5°, 18°, and 37°), the droplet diameters fall in the range of 2 to 4 μm and 3 to 5 μm at t = 0 s and t = 5 s respectively. With an increase in the WCA between 60° and 145°, the droplet diameters are in the range of 3 to 5 μm and 4 to 6 μm at t = 0 s and t = 5 s respectively. This is quite non-intuitive as the contact line diameter of droplets is expected to be larger on surfaces having a smaller WCA. The results suggest that droplets impact on the surface at a time point earlier than one second, and smaller impacting droplets can stay over surfaces having smaller WCA. On the other hand, smaller droplets impacting over surfaces having higher WCA roll-off or bounce back and only larger droplets formed through coalescence with incoming droplets stay on such surfaces. For all the surfaces, a polydisperse nature is observed in the size distribution of the droplets. Depending on the contact angle of the wettable substrate where these droplets are allowed to impact, only some of the droplets are captured. As seen in Fig. 4a and b, an increase in the diameter range between t = 0 s and t = 5 s is due to the coalescence of the droplets on the surfaces. The evaporation of thin films (1–50 μl) is reported to be in minutes.69 Since the SAW actuation and subsequent atomization effects are performed within a few seconds, the effects of evaporation on the droplet transfer can be neglected. The effect of evaporation on the size of the transferred droplets is not considered here.
Fig. 5 (a) Schematic diagram of the model geometry depicting a droplet before and after impact. (b) Comparison of the theoretical Dm values with the measured experimental average Dm values. |
Considering H and L as the characteristic height and length scale of the liquid thin film, which is generated during SAW actuation, Wang et al.36 reported an expression of the diameter of ejected droplets (Do) as follows,
(1) |
(2) |
(3) |
Depending on the geometric profile of the generated liquid film, i.e. (ϵ = H/L) ratio, different expressions are suggested for estimating the fc. For ϵ ≪ 1, the regime is considered to be a capillary resonant condition due to the internal viscous damping of the liquid and fc is estimated as
(4) |
On the other hand, for ϵ ≫ 1, the regime is considered to be capillary resonant frequency due to the inertial forcing of the drop and fc is estimated as
(5) |
In the present case, since ϵ ≪ 1, as seen in Fig. 3a, and the regime can be considered satisfying the viscous-capillary resonant condition28,32,36 and the capillary wave frequency can be calculated from eqn (4) as fc ∼ 0.27 MHz. Thus, by taking the different values into eqn (1), Do is calculated as 3.08 μm.
The ejected droplets from the liquid meniscus impact the surface and undergo spreading to attain their equilibrium contact line diameters at the maximum spreading position. A general approach is to balance the sum of the initial kinetic energy (KEi) and interfacial energy (SEi) of the ejected droplets with the sum of the viscous energy dissipated during spreading (VE) and interfacial energy at the maximum spread (IEm) position on the substrate.71–73 Hence, from the principle of conservation of energy we get,
KEi + SEi = VE + IEm | (6) |
(7) |
SEi = πγDo2 | (8) |
(9) |
Here v represents the velocity of the droplet just before impacting on the surface and θ represents the WCA. Normally, h is calculated73 by equating the volume of a spherical droplet of diameter Do with that of a cylinder of height h and diameter Dm as the splat is assumed to be cylindrical in shape as follows,
(10) |
Now, VE is estimated from the energy spent to overcome the friction force,73,74 which is given as follows,
(11) |
Upon substitution of the above parameters in eqn (11), VE is expressed as
(12) |
Combining the eqn (7)–(9) and (12) and substituting in eqn (6), and taking the dimensionless maximum spreading parameter as , we get
(13) |
To obtain β, it is essential to know the velocity v of the droplet during the impact. Due to experimental constraints in measuring individual droplets during their impact on various wettable substrates, the approximate value of the velocity is taken into consideration. Through experimental observations, the time droplets taken to appear on the coverslip substrate, after SAW actuation, is measured as 0.6 ms. From literature, the time for the mist generation is known to be 0.2 ms,27,37 thus the time of flight is found to be 0.4 ms. The coverslip substrate is kept at a distance of 10 mm from the LiNbO3 substrate, using this the velocity of the drop just before impact is estimated to be v ≈ 25 m s−1. By placing the values in eqn (13), β is calculated and Dm is obtained by taking Do as 3.08 μm.
This model predicts the initial droplet spreading diameter when the time t = 0 s and does not take into consideration the impact of multiple droplets. Thus, the obtained theoretical values is compared with the experimental average Dm for various WCAs which is measured at time t = 0 s. The experimental average Dm is calculated from the Gaussian size distribution (Fig. 4a).
Based on the size distribution for the droplets captured, the experimental average Dm for various WCAs is measured and compared with the theoretical results obtained from eqn (13) (Fig. 5b). The results show that the Dm decreases with the increase in WCA experimentally and the same trend is observed for the theoretical values also. Even though the error between experimental and theoretical values is minimal (<1%), there is scope of improvement for the theoretical model if the velocity of the drop can be measured accurately rather than estimating the magnitude of the velocity.
The variation of PDI with WCA at time t = 0 s and 5 s are presented in Fig. 6a(a-i). It is observed that the PDI decreases with an increase in the WCA, which can be attributed to the fact that droplets deposited onto a hydrophilic surface tend to spread more and therefore have a higher tendency to coalesce leading to a higher PDI. For a given surface with a fixed WCA, the successive coalescence of droplets gives rise to the formation of a larger number of uniform coalesced droplets, leading to a reduction in polydispersity with time, as observed between t = 0 and 5 s. The experimental images of coalescence of adjacent droplets on surfaces having WCA = 5° and 18° are depicted in Fig. 6b(b-i–iv).
We find that the PDI is dependent on the interdistance between the adjacent droplets, which in turn is related to Nd. The interdistance between adjacent droplets is smaller for a surface with a smaller WCA (Fig. 6a(a-ii)). As WCA increases the droplet spreads less on the surface and the tendency of the droplet to rebound and leave the surface increases hence a lower droplet density is observed with a higher WCA (Fig. 6a(a-iii)). On the other hand, at lower WCA, the droplets tend to spread more thereby maximizing their Dm71,77 and incurring higher viscous losses which reduce their tendency to rebound from the surface and also reduce the inter-distance between the droplets. In the case of the superhydrophobic surface with WCA of 110° and 145°, PDI is found to be less than 0.1 for all times indicating a mono-disperse nature.78,79 PDI is found to be >0.1 for all other cases indicating the polydisperse nature of the formed droplets.
On superhydrophobic surfaces with WCA of 110° and 145°, the droplets tend to rebound from the surface77,80 and some disappear quickly after getting deposited onto the surface. In Fig. 6c(c-i and ii) the droplets encircled with dotted lines disappear after 0.5 s. With the reduction in droplet size, the capillary forces become stronger leading to a higher rebounding tendency than larger droplets.72 Further, for smaller size droplets, the surface area to volume ratio is higher leading to a higher rate of evaporation. As some of the smaller droplets rebound off the surface or quickly evaporate, the average inter-distance increases thereby reducing the coalescence tendency. This leads to a reduction in the droplet density thus providing a monodisperse droplet distribution at higher WCAs.
A liquid sample (10 μl) containing quantum dot conjugated streptavidin solution and 10% Optiprep is prepared and loaded onto the lint-free paper. After drying the paper strip at room temperature, it is soaked with DI water from the reservoir through the wicking process and a liquid meniscus containing protein molecules is established. A fluorescent image of the proteins in the liquid meniscus is shown in Fig. 7a. Initially, before SAW actuation, the coverslip substrate is devoid of any protein (Fig. 7b). When SAW is actuated with the timer circuit set at 100 ms, droplets containing the proteins get transferred (inset of Fig. 7b) onto the coverslip substrate. The interface in the inset of Fig. 7b demarcates the regions of the substrate deposited with droplets containing protein molecules and the bare substrate. An experimental image of the proteins transferred onto the substrate, after complete evaporation of the droplets, is presented in Fig. 7c. While transferring the droplets onto the wettable surface by SAW, the coffee ring effect was not observed on the LiNbO3 substrate. Suppression of the coffee ring effect by acoustic waves has been reported in the literature.81 The dynamic patterns of solute particle formed inside the liquid film, during SAW actuation, inhibit the evaporation driven transport of the particles towards the contact line, thereby suppressing the coffee-ring effect. Thus, the low-power non-contact method of producing droplets from a liquid meniscus can be used for the transfer of bioreagents onto preferred substrates.
Footnotes |
† Electronic supplementary information (ESI) available. See https://doi.org/10.1039/d2ra04089a |
‡ Current address: Department of Mechanical Engineering, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Chennai-601103, India. |
This journal is © The Royal Society of Chemistry 2022 |