Sakshi Gandhi and
Suneet Kumar Awasthi*
Department of Physics and Material Science and Engineering, Jaypee Institute of Information Technology, Noida 201304, U.P., India. E-mail: suneet_electronic@yahoo.com
First published on 24th October 2022
In this study, the reconfigurable biosensing capabilities of the one-dimensional annular photonic structure, (AB)5CDC(AB)5, was examined theoretically. The proposed structure was made of concentric cylindrical layers of periodically modulated refractive indices, which were restricted in one direction only. Germanium antimony telluride (GST), which belongs to the class of phase-change materials (PCMs), was used in the fabrication of the proposed biosensing design. The entire study was carried out in the near-infrared region of the electromagnetic spectrum. The suggested biosensing structure was constructed by depositing alternate periodic cylindrical layers of SiO2 and Si with a central air core. An air cavity coated on both sides by a phase-change chalcogenide material (Ge2Sb2Te5) was introduced at the centre of the 1D annular photonic crystal to realize the (AB)5CDC(AB)5 structure. The simulation results of the proposed work were obtained using the MATLAB computational tool taking into consideration the modified transfer matrix method. The primary focus of this study was to measure the change in the position and intensity of the defect mode with respect to the change in the concentration levels of analytes containing progesterone and estradiol reproductive hormones separately in the amorphous and crystalline phases of the Ge2Sb2Te5 material. Interestingly, a strong tunability in the position of the central wavelength of the defect mode inside the photonic band gap (PBG) was noticed during the phase transition of the GST material from amorphous to crystalline and back. In both the phases of the GST material, our design could identify minute refractive index variations in blood samples containing reproductive hormones at different concentrations for monitoring various gynaecological disorders in women. Besides sensitivity, other important parameters such as the limit of detection, signal-to-noise ratio, and quality factor were estimated to evaluate the biosensing capabilities of the proposed design.
From the beginning of the previous century, the importance of maintaining hormone levels in the human body was recognized, and consequently considerable significant research work associated with different kinds of innovative biosensors capable of detecting the concentrations of various hormone levels in the human body have been developed. Most of the biosensors that are being used by biomedical professionals are based on immunometric assay approaches for the accurate identification and detection of the concentration levels of various hormones in the body. Nonetheless, biosensors based on immunometric assay approaches have several disadvantages, including time efficiency, low sensitivity, accuracy rate, and selectivity.13–16 Besides, traditional pathological investigation requires experienced laboratory staff and well-equipped laboratories to conduct specific pathological tests for identifying the levels of particular hormones in the human body.17,18 The currently available photonic biosensing technology may provide a solution to these technological challenges in a better way.
The past few decades have witnessed the emergence of photonic crystals (PhCs) as a promising candidate to design and develop various optical devices with a tremendous ability to control and manipulate the flow of electromagnetic waves (EMWs) passing through them.19 PhCs are engineered multilayer periodic structures in which the periodic arrangement of the constituent material layers is in one, two, or three dimensions of space. Based on the periodic arrangement of the constituent layers, PhCs can be classified into one-dimensional (1D), two-dimensional (2D), or three-dimensional (3D).20 The fabrication of 1D PhCs is very simple and cost effective in contrast to 2D and 3D PhCs, which attracted the attention of researchers working in the field of photonic engineering to make cost-effective photonic products to reach common people. Actually PhCs have a tremendous capability for controlling and manipulating electromagnetic waves because they possess photonic band gaps (PBGs).21,22 The ranges of frequencies of incident electromagnetic radiation which lies inside PBGs are not permitted to travel into the structure except for the radiation of frequencies which lies outside.23 A break in the periodicity of photonic structures can lead to the existence of a defect mode with high transmittance inside the PBG of the structure due to photon confinement inside the cavity region. The width of the PBG and the defect mode position inside the PBG are strongly affected by changes in the structural variables, like in the refractive index of the materials used, the thickness of distinct layers, and the incident angle, period number, and nature of the polarization of incident light. The PBG characteristics of 1D photonic structures are also responsible for affecting the reflection, absorption, and transmittance properties of the structure. It is thought that the PBG-dependent optical properties of photonic structures may be used to improve the working of a wide range of optical devices, such as biosensors, photodetectors, lasers, solar cells, optical switches, and photonic waveguides.24–26 Additionally, the biosensing abilities of annular photonic crystals (APCs) have also attracted the attention of researchers worldwide for the development of highly efficient photonic biosensing structures due to the efficiency, rapidity, accuracy, and sensitivity found in the results of biosensors composed of APCs. Such APCs are made up of concentric and periodic cylindrical layers whose refractive index variation is restricted only in one direction.27,28 Moreover, the necessity of examining the levels of reproductive hormones has attracted us towards the development of a 1D APC-based biosensor with the special ability to sense and detect the reproductive hormone levels in both males and females. These hormones are also known as sex hormones and can be easily examined through the blood or urine samples of the patient. Nowadays, a wide range of photonic biosensing technology-based biosensors are available for the effective investigation of the biological and chemical properties of the samples under consideration. These samples are termed as analytes. For example, Hussein et al. theoretically explored the temperature-detection abilities of a 1D defective annular photonic crystal (DAPC). They used a modified transfer matrix method approach based on a cylindrical coordinate system.29–31 Arafa et al., on the other hand, proposed how a 1D APC could be utilized efficiently as an effective air purifier in the ultraviolet (UV) region of the electromagnetic spectrum for minimizing the possibility of spreading airborne communicable diseases, like COVID-19.32 Moreover, Abadla et al. suggested a highly efficient Tamm/Fano resonance-based 1D APC biosensor capable of identifying the refractive index fluctuations of biofluids ranging from 1 to 1.5.33 The aforementioned biosensing capabilities of 1D APC-based structures have attracted the attention of researchers globally for designing different types of biosensors as a low cost and efficient alternative compared to conventional biosensing designs.
The above-mentioned piece of remarkable research work motivated us to explore a way by which a 1D defective annular photonic structure could be used as a bi-stable and reconfigurable biosensor for the effective detection of the reproductive hormone levels in the human body.34–40 Another reason behind this motivation was to examine the bi-stable and reconfigurable behaviour of the 1D defective annular photonic structure with GST-coated cavity walls similar to the work of Arafa et al., who conducted a study on 1D planar photonic structures for the detection of the reproductive hormones via the blood samples of women.41,42 The working principle of our proposed annular photonic structure is based on the detection of a small change in the refractive index of a blood sample containing reproductive hormones of different concentrations present in the sample under consideration. To the best of our knowledge, such a kind of bi-stable and reconfigurable biosensing device composed of 1D defective APC with GST-coated cavity walls for the detection of the estradiol and progesterone hormone levels present in a blood sample has not been investigated to date. This manuscript is organized as follows. Section 1 presents the introduction to the proposed work. The design specifications are discussed in Section 2. Theoretical formulations pertaining to the work are given in Section 3. Section 4 deals with the results and discussions pertaining to the work. Finally, Section 5 of this manuscript presents the conclusion of the work.
For experimental realization of the proposed work, we used a wide-band light source at the axis of the annular photonic structure in addition to a single mode fibre and direction couplers. The blood sample circulation chamber was installed near the top of the cavity layer with the facility of IN and OUT ports. These ports were utilized for sample loading and extraction. A shift in the position of the defect mode due to changes in the concentration levels of different reproductive hormones present in the blood sample inside the PBG could be easily analyzed on the computer screen with the help of an optical spectrum analyzer and interfacing software. Moreover, we had to comply with all the well-known sets of rules and regulations for the preparation of reproductive hormones of different concentration levels extracted from human blood as one of the mandatory requirements for obtaining the desired level of accuracy from the results biosensors.
The optimum thicknesses of the concentric and periodic coaxial cylindrical layers A, B, C, and D were chosen as d1 = 390 nm, d2 = 180 nm, d3 = 50 nm, and dD = 1150 nm, respectively. The refractive indices of layers A and B were taken as 3.3 and 1.45, respectively, in the near-infrared region of the electromagnetic spectrum. The period number N was fixed as 5.
The unit cell of the periodic part of the proposed design consisted of the cylindrical layers A and B, as shown in Fig. 1. The refractive indices and thicknesses of the A and B layers were denoted as n1 and n2 and d1 and d2, respectively. The radial distance of the ith cylindrical layer from the axis of the 1D defective APC is as described in ref. 43–45 and as below:
(1) |
(2) |
The elements of the matrix Xi are described as
(3a) |
(3b) |
(3c) |
(3d) |
The resultant transfer matrix Z connecting the first to last interfaces of all the cylindrical layers used in the formation of the proposed defective APC structure (AB)5CDC(AB)5 can be established as
(4) |
The transmission coefficient of the proposed 1D defective APC structure can be obtained as
(5) |
(6) |
(7) |
The Hankel functions of the first and second kind are denoted as the notations H(1)m and H(2)m, respectively. Here, the notations are representing their respective derivatives.
The transmittance of the proposed photonic biosensing device is obtained from ref. 43–45 and is given by the equation below.
T = tt* = |t|2 | (8) |
The complex refractive index of GST under amorphous and crystalline phases was defined in eqn (9) and (10), respectively. Experimentally determined complex refractive index values of GST under amorphous and crystalline phases were used to establish the theoretical relations in eqn (11)–(14), representing the wavelength-dependent real and imaginary parts of the complex refractive index values of GST under amorphous and crystalline phases. Polynomial curve fitting of degrees 4 and 5 were utilized to ensure a greater accuracy and precision between the theoretical and experimental findings.
na = naGST + iKaGST | (9) |
nc = ncGST + iKcGST | (10) |
naGST = −0.51929λ4 + 4.3531λ3 − 12.984λ2 + 15.789λ − 2.0315 | (11) |
KaGST = −0.29346λ3 + 2.3145λ2 − 5.9547λ + 4.9925 | (12) |
Similarly, a curve fitting formula can also be applied to obtain the wavelength-dependent real and imaginary parts of the complex refractive index of GST under the crystalline phase, as given in eqn (13) and (14), respectively, below
ncGST = 1.2751λ3 − 8.1973λ2 + 16.168λ − 2.9464 | (13) |
KcGST = −0.72443λ4 + 5.461λ3 − 13.331λ2 + 9.7612λ + 1.8907 | (14) |
Additionally, in the near-infrared region, GST reflects a significant contrast between the complex refractive index values under the amorphous and crystalline phases. The capability of a change in the refractive index values of GST under the amorphous and crystalline phases offers a novel pathway towards developing tuneable and reconfigurable photonic biosensors with extremely high sensitivity.
Next, we defined eqn (15) and (16) for determining the refractive index of blood samples containing progesterone and estradiol reproductive hormones, respectively, at different concentrations.39,40 These relations were determined by using cubic curve fitting applied on an experimentally observed refractive index of values of blood samples containing progesterone and estradiol hormones of different concentrations.
np = 4.2882 × 10−8c3 + 2.2847 × 10−6c2 + 4.5962 × 10−5c + 1.3352 | (15) |
ne = 2.678 × 10−4c3 + 1.7648 × 10−3c2 + 3.7489 × 10−3c + 1.3333 | (16) |
Reproductive hormones | |||
---|---|---|---|
Progesterone | Estradiol | ||
Concentration (nmol L−1) | Refractive index | Concentration (nmol L−1) | Refractive index |
0 | 1.3352 | 0 | 1.3333 |
40 | 1.3361 | 5 | 1.3413 |
80 | 1.3462 | 7 | 1.3647 |
120 | 1.3819 | 9 | 1.4190 |
160 | 1.4596 | 11 | 1.5170 |
200 | 1.5961 |
The transmittance of the suggested design under identical circumstances as elaborated above in the amorphous phase of Ge2Sb2Te5 was plotted and the results are shown in Fig. 2(b). This shows that as we switched the phase of Ge2Sb2Te5 from crystalline to amorphous, the central wavelength of the defect mode earlier located at a wavelength of 2220 nm was relocated to a new position at a wavelength of 2420 nm. Additionally, this change in phase of GST also advanced the PBG to a new position between 2300 nm to 2550 nm, as shown in Fig. 2(b). The transmittance of the defect mode under the amorphous phase of GST inside the PBG located at 2420 nm was reduced by 80% due to the increase in the imaginary part of the complex index of refraction of Ge2Sb2Te5 when in the amorphous phase. In both cases, the full width at half maximum (FWHM) was narrow, which is an essential requirement for the design of any high-performance biosensors. Thus, it can be concluded that the PCM-based APCs can be employed for the fabrication of reconfigurable, bi-stable, and tuneable photonic biosensors.
Next, efforts were made to examine the behaviour of the proposed photonic biosensing design when its cavity was loaded separately with blood samples containing progesterone hormone at different concentration levels under the influence of the amorphous phase of Ge2Sb2Te5. This study was conducted to verify our claim that the proposed structure can be used as a bi-stable and reconfigurable photonic biosensor. For this purpose, the cavity region of the proposed 1D photonic biosensor (AB)5CDC(AB)5 composed of 1D defective APC was infiltrated with blood samples containing progesterone hormone at concentrations of 0, 40, 80, 120, 160, and 200 nmol L−1, separately, under the amorphous phase of GST. The transmittance of the proposed biosensor loaded with analytes containing progesterone hormone at concentrations of 0, 40, 80, 120, 160, and 200 nmol L−1 are plotted in Fig. 3(b). This shows six distinguishable defect modes coloured here blue, red, yellow, purple, green, and light blue corresponding to blood samples containing progesterone hormones at concentrations of 0, 40, 80, 120, 160, and 200 nmol L−1, respectively, inside the PBG ranging from 2400 nm to 2650 nm. It is evident from Fig. 3(b) that the increase in the concentration of progesterone present in the analyte was responsible for the movement of the PBG and the respective defect modes located inside the PBG towards the higher wavelength side. Surprisingly, we also noted that all the defect modes had almost identical intensities located inside the PBG, ranging from 2400 nm to 2650 nm. The intensities of the defect modes were close to 80%, which would be more than enough to be detected by an optical spectrum analyzer used. The variation in the intensity of defect modes associated with the different samples under investigation is one of the major drawbacks involved with the structures used for photonic biosensing applications. Comparisons among the results in Fig. 3 showed that the use of Ge2Sb2Te5 in the amorphous phase overcome the drawbacks of the intensity variation associated with the defect modes of the proposed structure loaded with different samples with the crystalline phase of GST. This study may also provide an insight to promote the use of GST in the amorphous phase in the design of biophotonic sensors to overcome the drawbacks of the intensity variations that occur in the defect modes of photonic biosensors loaded with different samples.
Finally, we turned our attention to examining the behaviour of the proposed design loaded with analytes containing estradiol hormones at different concentrations of 0, 5, 7, 9, and 11 nmol L−1, separately, under the influence of the amorphous phase of Ge2Sb2Te5 and a cavity thickness dD of 1150 nm. The transmittance of the proposed biosensor loaded with analytes containing estradiol hormones at the aforementioned concentration levels was plotted and the results are shown in Fig. 4(b). As can be seen in Fig. 4(b), five defect modes were distinguishable, here coloured blue, red, yellow, purple, and green, corresponding to analytes containing estradiol hormones at different concentrations of 0, 5, 7, 9, and 11 nmol L−1, respectively, inside the PBG extending from 2375 nm to 2640 nm. This also reflected that as the concentration of estradiol present in the analyte under investigation increased, the central wavelength of the respective defect modes inside the PBG ranging from 2375 nm to 2640 nm moved towards the higher wavelength side. This behaviour was similar to the results in Fig. 3. All five defect modes inside the PBG of the design originated due to the infiltration of the cavity of the structure with analytes containing estradiol hormones at concentrations of 0, 5, 7, 9, and 11 nmol L−1, separately. All these defect modes had an identical intensity of 80%, as evident in Fig. 4(b). The energy associated with each defect mode would be more than sufficient to meet the threshold value of the detector for accurate sensing and detection.
The comparison between the nature of transmittance of the proposed 1D defective APC-based biosensing design (AB)5CDC(AB)5 infiltrated with blood samples containing progesterone and estradiol hormones of various concentration levels under the influence of the crystalline and amorphous phases of Ge2Sb2Te5 as shown in Fig. 3 and 4, respectively, illustrated the bi-stable and reconfigurable behaviour of the proposed biosensor. Moreover, these results were also reflected in the FWHM of each defect mode of the structure loaded with both types of blood samples containing progesterone and estradiol hormones being smaller in the case with the crystalline phase of Ge2Sb2Te5. A small FWHM is always an essential requirement for the design of sensitive photonic biosensing devices. Our study successfully demonstrated that under both phases of Ge2Sb2Te5 the proposed 1D defective APC-based photonic biosensor (AB)5CDC(AB)5 was capable of identifying minute changes in the refractive index of different blood samples containing progesterone and estradiol hormones of various concentration levels. The infiltration of various blood samples did not cause any significant reduction in the intensity of the defect modes, which makes our design suitable to be used for the accurate sensing and detection of reproductive hormones under the influence of both the crystalline and amorphous phases of Ge2Sb2Te5. The involvement of the phase-change material (PCM) in the fabrication of the structure makes our design bi-stable and reconfigurable.
(17) |
The parameter Q indicates how effectively a biosensor can work, and indicates how small a change in the refractive index of a sample could still be precisely and accurately sensed by any biosensor. For quality biosensing applications, a high value of Q is always preferred. It is defined as,
(18) |
The parameter FoM is directly proportional to the sensitivity of any biosensing device and is inversely proportional to the FWHM of the defect mode inside the PBG. For any biosensor to work efficiently, a large FoM value is always required. The FoM is defined as,
(19) |
Besides the above parameters, two more parameters, namely the SnR and LoD, were also investigated to appraise the effective working of the proposed biosensor, as defined mathematically in eqn (20) and (21), respectively.
(20) |
(21) |
Based on the parameters described above in eqn (17)–(21), we evaluated the performance of our suggested 1D defective APC-based photonic biosensing design (AB)5CDC(AB)5 with coated cavity walls loaded with analytes containing progesterone and estradiol of different concentration levels under the crystalline and amorphous phases of Ge2Sb2Te5. The numerical values of S, Q, FoM, LoD, and SnR were calculated from eqn (17)–(21), respectively, and are summarized in Tables 2 and 3 for when the structure was loaded with analytes containing progesterone and estradiol at different concentration levels under the crystalline phase of Ge2Sb2Te5, respectively.
c (nmol L−1) | Refractive index (RIU) | Wavelength (nm) | FWHM (nm) | Sensitivity (nm nmol−1 L−1) | Quality factor | FoM (nmol L−1) | LoD | SnR |
---|---|---|---|---|---|---|---|---|
0 | 1.3352 | 2218 | 0.180 | 12322.22 | 0.009 | |||
40 | 1.3361 | 2219 | 0.225 | 1111.11 | 9862.22 | 4938.27 | 1.013 × 10−5 | 4.44 |
80 | 1.3462 | 2228 | 0.225 | 909.09 | 9902.22 | 4040.40 | 1.238 × 10−5 | 44.44 |
120 | 1.3819 | 2259 | 0.225 | 877.94 | 10040.00 | 3901.97 | 1.281 × 10−5 | 182.22 |
160 | 1.4597 | 2329 | 0.225 | 891.59 | 10351.11 | 3962.52 | 1.262 × 10−5 | 493.33 |
200 | 1.5951 | 2454 | 0.180 | 908.04 | 13633.33 | 5044.68 | 9.91 × 10−6 | 1311.11 |
c (nmol L−1) | Refractive index (RIU) | Wavelength (nm) | FWHM (nm) | Sensitivity (nm nmol−1 L−1) | Quality factor | FoM (nmol L−1) | LoD | SnR |
---|---|---|---|---|---|---|---|---|
0 | 1.3352 | 2416 | 0.225 | 10737.78 | 0.01125 | |||
40 | 1.3361 | 2417 | 0.315 | 1111.11 | 7673.02 | 3527.34 | 1.418 × 10−5 | 3.17 |
80 | 1.3462 | 2426 | 0.315 | 909.09 | 7701.59 | 2886.00 | 1.733 × 10−5 | 31.75 |
120 | 1.3819 | 2455 | 0.27 | 835.12 | 9092.60 | 3093.03 | 1.617 × 10−5 | 144.44 |
160 | 1.4597 | 2519 | 0.315 | 839.45 | 7996.83 | 2664.91 | 1.876 × 10−5 | 326.98 |
200 | 1.5951 | 2628 | 0.495 | 1111.11 | 5309.09 | 2241.67 | 2.228 × 10−5 | 428.28 |
In all this work, we used the optimized value of the cavity layer as dD = 1150 nm. To determine this optimum value, we measured the sensitivity of the design loaded with blood samples containing reproductive hormones of different concentrations with varying dD thicknesses of 650, 750, 850, 950, 1050, 1150, and 1250 nm, separately. This process helped us to estimate the optimum value of the cavity layer thickness. For example, we present a plot of the sensitivity versus cavity layer thickness of the proposed structure loaded with a blood sample containing estradiol hormone at 7 nmol L−1 under the influence of the amorphous phase of GST in Fig. 5. This figure shows that the sensitivity of the proposed design reached a maximum value of 828.03 nmol L−1, corresponding to dD = 1150 nm. Further increases in the cavity layer thickness affected the sensitivity of the proposed APC structure; therefore, our choice of selecting the optimum value of cavity layer thickness as dD = 1150 nm in this work is justified.
Fig. 5 Sensitivity versus cavity layer thickness variations of the proposed structure loaded with a blood sample containing estradiol hormone at 7 nmol L−1 under the amorphous phase of GST. |
The numerical values of S, Q, FoM, LoD, and SnR of the proposed biosensor loaded with analytes containing progesterone hormone at different concentrations of 0, 40, 80, 120, 160, and 200 nmol L−1 under the crystalline phase of Ge2Sb2Te5 are listed in Table 2. It can be seen in the table that the sensitivity of the design varied between 877.94 nm nmol−1 L−1, corresponding to the blood sample containing progesterone hormones at 120 nmol L−1, and 1111.11 nm nmol−1 L−1, corresponding to the sample with a concentration of 40 nm nmol−1 L−1. The maximum achieved value of the FoM of the proposed biosensor was 5044.68 nmol L−1. This value was high, as expected. The lowest achieved LoD value was 9.91 × 10−6. The SnR values of the proposed design varied between 4.44 and 1311.11.
Next, we examined the performance of the proposed structure loaded with analytes containing progesterone hormones at concentration levels of 0, 40, 80, 120, 160, and 200 nmol L−1 under the amorphous phase of Ge2Sb2Te5 by evaluating the parameters S, Q, FoM, LoD, and SnR as mentioned above with the help of eqn (17)–(21), respectively. The data are listed in Table 3 below. Comparison of the data presented in Table 2 with Table 3 shows that under the influence of the amorphous phase of Ge2Sb2Te5, the performance of the proposed structure loaded with progesterone hormones at the different concentration levels was marginally compromised due to the increase in the imaginary part of the complex refractive index of Ge2Sb2Te5 when in the amorphous phase in comparison to in the crystalline phase. These observations are similar to the findings of Arafa et al.41
Next, linear curve fitting was applied on the data in Tables 2 and 3 to observe the behaviour of the changes in the position of the defect mode corresponding to blood samples containing progesterone hormones at different concentration levels under the influence of the crystalline and amorphous phase of GST, respectively. This linear curve fitting yielded two empirical relations, eqn (22) and (23), which gave straight line plots, as shown in Fig. 6(a) and (b), corresponding to the crystalline and amorphous phases of GST, respectively. The empirical relations eqn (22) and (23) as defined below are plotted in Fig. 6(a) and (b), respectively. The straight lines plotted in Fig. 6 gave slopes of 892.16 and 815.03, which indicated respective sensitivities of 892.16 nm per RIU and 815.03 nm per RIU under the crystalline and amorphous phases of GST. It is clear from the slopes from eqn (22) and (23) that the structure was more sensitive for observing changes in the refractive index of the sample containing progesterone hormones at different concentrations under the crystalline phase of GST as compared to the amorphous phase.
(λpD)Cry = 906.52np + 1007.2 | (22) |
(λpD)Amo = 815.03np + 1328.4 | (23) |
Further, we evaluated the performance of our proposed design loaded with estradiol hormones of various concentration levels under the influence of the crystalline phase of Ge2Sb2Te5. The numeric values of S, Q, FoM, LoD, and SnR of the proposed design loaded with blood samples containing estradiol hormones at concentrations of 0, 5, 7, 9, and 11 nmol L−1 under the influence of the crystalline phase of Ge2Sb2Te5 are listed in Table 4.
c (nmol L−1) | Refractive index (RIU) | Wavelength (nm) | FWHM (nm) | Sensitivity (nm nmol−1 L) | Quality factor | FoM (nmol L−1) | LoD | SnR |
---|---|---|---|---|---|---|---|---|
0 | 1.3330 | 2217 | 0.315 | 7038.09 | 0.01575 | |||
5 | 1.3413 | 2224 | 0.270 | 873.80 | 8237.04 | 3236.29 | 1.545 × 10−5 | 25.93 |
7 | 1.3647 | 2244 | 0.315 | 858.52 | 7123.81 | 2725.46 | 1.835 × 10−5 | 85.71 |
9 | 1.4190 | 2292 | 0.270 | 874.81 | 8488.89 | 3240.03 | 1.543 × 10−5 | 272.78 |
11 | 1.5170 | 2381 | 0.315 | 892.68 | 7558.73 | 2833.90 | 1.764 × 10−5 | 520.63 |
The above-mentioned performance–evaluation parameters of the proposed structure loaded with blood samples containing estradiol hormones at different concentration levels under the amorphous phase of Ge2Sb2Te5 are listed in Table 5. Again, we noticed that the sensing performance of the proposed structure loaded with blood samples containing estradiol hormones at different concentration was little bit compromised in the amorphous phase of Ge2Sb2Te5 in comparison to the crystalline phase.
c (nmol L−1) | Refractive index (RIU) | Wavelength (nm) | FWHM (nm) | Sensitivity (nm nmol−1 L) | Quality factor | FoM (nmol L−1) | LoD | SnR |
---|---|---|---|---|---|---|---|---|
0 | 1.3330 | 2415 | 0.315 | 7666.67 | 0.01575 | |||
5 | 1.3413 | 2422 | 0.360 | 875.00 | 6727.78 | 2430.56 | 2.057 × 10−5 | 19.44 |
7 | 1.3647 | 2441 | 0.315 | 828.03 | 7749.21 | 2628.65 | 1.902 × 10−5 | 82.54 |
9 | 1.4190 | 2486 | 0.315 | 828.47 | 7892.06 | 2630.07 | 1.901 × 10−5 | 222.22 |
11 | 1.5170 | 2565 | 0.450 | 816.55 | 5700.00 | 1814.55 | 2.756 × 10−5 | 333.33 |
Further, efforts were made to study the behaviour of the changes in the position of the defect mode due to changes in the refractive index of blood samples containing estradiol hormones at various concentration levels under the crystalline and amorphous phase of GST by applying linear curve fitting on the data in Tables 4 and 5, respectively, as discussed above. The linear curve fitting yielded two empirical relations that govern the movement of the defect mode inside the PBG of the proposed structure loaded with blood samples containing estradiol hormones at different concentration levels, as described below in eqn (24) and (25), under the influence of the crystalline and amorphous phases of GST, respectively.
(λeD)Cry = 892.16ne + 1027 | (24) |
(λeD)Amo = 815.39ne + 1328.3 | (25) |
The above empirical relations are plotted in Fig. 7 below, which shows straight lines corresponding to the crystalline and amorphous phases of GST. The slopes of the lines plotted in Fig. 7(a) and (b) were 892.16 and 815.39, respectively. This yield that the sensitivities of the structure loaded with blood samples containing estradiol under the crystalline and amorphous phase were 892.16 nm per RIU and 815.39 nm per RIU, respectively. Additionally, the structure was more sensitive under the crystalline phase as compared to the amorphous phase. In both cases, the sensitivity reached an ultrahigh level compared to the results reported in ref. 41 and 42.
It can be clearly seen from the data presented in Tables 2 and 4 that under the influence of the crystalline phase of Ge2Sb2Te5 loaded with blood containing progesterone and estradiol hormones at different concentration levels separately, the sensing abilities of the proposed design were significantly enhanced as compared to the sensing abilities of the structure under the amorphous phase of Ge2Sb2Te5. Moreover, the sensing ability of the structure under both phases of Ge2Sb2Te5 was sufficient for the minute and accurate detection of reproductive hormones at different concentrations present in the samples. Additionally, the involvement of GST makes our 1D defective APC structure a bi-stable and reconfigurable biosensor.
Thus our design can be used for the sensing and detection of blood samples containing reproductive hormones at different concentration levels under the crystalline and amorphous phases of Ge2Sb2Te5. GST can be a preferable choice for the design and development of 1D defective annular photonic structure-based biosensing devices for the detection of minute changes in the refractive index of samples under consideration. Furthermore, an inbuilt switching property between the crystalline and amorphous phases of GST can open a new gateway for the development of APC-based externally tuneable biophotonic devices.
Finally, before concluding this work, we present a quick comparison between the proposed work and the earlier works of distinguished researchers based on photonic biosensing technology. This comparison shows that the APC structures can be better choice for designing various biosensors over planar photonic crystals. The proposed design has a higher sensitivity, ranging from 816 to 1111.11 nm nmol−1 L−1, which represents an ultrahigh sensitivity compared to similar kinds of biosensing work based on planar photonic structures for the detection of reproductive hormones.41,42 The orders of the Q factor and FoM values of our design were either equal or higher compared to those in previous works given in Table 6 below. This shows that the suggested biosensor had a reasonably higher sensitivity and much better performance compared to similar kinds of sensors in other research works for the detection of reproductive hormones in females. Fig. 8 below presents the statistical requirements of our work in terms of sensitivity in comparison to the similar kinds of photonic biosensing works presented in Table 6.
Year | S (nm per RIU) | Q factor | FoM | Frequency range | Ref. |
---|---|---|---|---|---|
2016 | 34.11 | — | 1.1 × 103 | THz | 46 |
2017 | 17 | 3 × 104 | 2.23 × 102 | Visible to NIR | 47 |
2019 | 53.0–90.9 | — | — | NIR | 48 |
2020 | 10 | 3 × 102 | 15.1 | Visible | 49 |
2021 | 137.02–30.44 | (0.12–1.43) ×104 | (0.2–2.7) ×103 | Visible | 41 |
2021 | 55.55–98.92 | (0.68–2.3) ×104 | (1.96–2.6) ×104 | Visible | 42 |
This work | 816.54–1111.11 | (0.57–1.36) ×104 | (0.22–0.5) ×104 | NIR |
Fig. 8 Annual statistical data comparing the performance of the proposed annular photonic biosensor with earlier designed biosensors in terms of the reported sensitivity. |