Ling Zhua,
Lujia Shib,
Yiping Tanb,
Huaiyin Zhangb,
Jiacheng Yinb,
Chang Xua,
Danlian Wua and
Yunsu Ma*b
aDepartment of Pharmacy, The Affiliated Jiangyin Clinical College of Xuzhou Medical University, Wuxi, PR China
bSchool of Pharmacy, Xuzhou Medical University, Xuzhou, PR China. E-mail: yunsu@xzhmu.edu.cn
First published on 21st October 2022
In this study, a sensitive ratiometric fluorescent nanosensor was constructed using a facile one-pot method by encapsulating carbon dots (CDs) and cadmium telluride quantum dots (CdTe QDs) into the pore cavities of a metal–organic framework (ZIF-8). In this nanosensor (CD/CdTe QD@ZIF-8), the fluorescence attributed to CdTe QDs was quenched by silver ions (Ag+), and the fluorescence intensity of CDs did not change. The introduction of ZIF-8 into the system can not only adsorb Ag+ but also easily separate CDs and CdTe QDs from the matrix. The developed CD/CdTe QD@ZIF-8 composite used as a ratiometric fluorescent probe exhibited high sensitivity and selectivity towards Ag+. The working linear range was 0.1–20 μM with a limit of detection (LOD) of 1.49 nM. Finally, the proposed nanosensor was applied to determine Ag+ in lake water with satisfactory results.
With attention to these concerns, the quantitative determination of the trace amount of Ag+ in environmental and industrial samples has significant implications. To date, various analytical methods have been applied to detect Ag+, such as atomic absorption spectroscopy,10 inductively coupled plasma optical emission,11,12 electrochemical analysis,13,14 and fluorescence analysis.15–17 However, these methods either lack selectivity and sensitivity or are laboratory-based and tedious in sample preparation. Among them, spectrofluorimetry has drawn great attention owing to its simple and convenient operations. Recently, several fluorescent nanosensors based on organic fluorescent dyes,18–20 semiconductor quantum dots,21–25 and CDs26–29 have been constructed for the determination of Ag+. However, traditional spectrofluorimetry based on a single fluorescence intensity is influenced by various factors, such as probe concentration, light source and measurement conditions. Alternatively, some ratiometric fluorescent probes30,31 have been reported. Compared with traditional spectrofluorimetry based on single fluorophore, ratiometric fluorimetry has higher selectivity and sensitivity and a wider quantitative range.
As the functional groups on the surface of QDs are rich in metal ions, heavy metal ions in the environment are exchanged with functional groups of QDs by electron transfer, resulting in the collapse of QDs and fluorescence quenching.1,6 While the functional groups on the surface of CDs were –NH2 or –COOH, electron transfer is potentially less likely to happen between CDs and heavy metal ions.26 Therefore, most QDs were more sensitive to heavy metal ions than CDs. These provide a chance to develop a ratiometric fluorescent probe to detect Ag+.
ZIF-8, as a member of metal–organic frameworks (MOFs), is a novel porous material synthesized by self-assembling zinc ions with 2-methylimidazole under certain conditions. Owing to its unique structural characteristics that are rich in porosity and active metal sites, ZIF-8 shows promising potential in many fields such as separation, adsorption and catalysis.32–34 As the introduction of ZIF-8 into the system can make CDs and CdTe QDs enclosed in its holes,35 the compounds (CD/CdTe QD@ZIF-8) possess several advantages. First, nanosize CDs and CdTe QDs are water-soluble and are difficult to extract from the matrix, CD/CdTe QD@ZIF-8 can easily be separated by centrifugation. Second, ZIF-8 can adsorb and enrich Ag+ from surroundings so that it plays an important role in improving sensitivity immensely.
Therefore, to develop a sensitive, selective and convenient fluorescent nanosensor, multi-nanoparticles, including CDs, CdTe QDs and ZIF-8, were chosen to construct a ratiometric fluorescence probe (CD/CdTe QD@ZIF-8) in this paper. The introduction of Ag+ causes the fluorescence quenching of CD/CdTe QD@ZIF-8 at 650 nm, but no change at 430 nm. The concentration-dependent percent quenching was calculated. Finally, the nanosensor was applied to sense Ag+ in lake water.
As shown in Fig. 1C, the absorption peaks at 240 nm and 360 nm were attributed to the n–π* and π–π* transitions of CC/CO, respectively. The CDs had a maximum fluorescence intensity of 430 nm based on the excitation wavelength of 365 nm.
The UV-vis absorption spectra and fluorescence spectra of CdTe QDs are also demonstrated in Fig. 1D. CdTe QDs had wide UV-vis absorption and an emission peak at 640 nm. The photometric characteristics of the prepared CDs and CdTe QDs were consistent with those reported in papers.23
The UV-vis absorption spectrum of CDs, CdTe QDs, ZIF-8 and CD/CdTe QD@ZIF-8 are depicted in Fig. 2A. The UV-vis absorption spectrum of CD/CdTe QD@ZIF-8 had a stronger and wider absorption than ZIF-8, which may be caused by the overlay of CDs and CdTe QDs. Furthermore, the characteristic absorption peaks of CDs at 240 nm and 360 nm disappeared in the UV-vis absorption spectrum of CD/CdTe QD@ZIF-8, which indicated that the CDs were covered by ZIF-8 not attached to the surface of ZIF-8. As shown in Fig. 2B, there were no obvious differences between the infrared spectrum diagrams of ZIF-8 and CD/CdTe QD@ZIF-8. Moreover, the correlative characteristic peaks attributed to CDs and CdTe QDs did not appear in CD/CdTe QD@ZIF-8. This indicated that the exterior structure of CD/CdTe QD@ZIF-8 had no significant changes compared with ZIF-8, which also proved that CDs and CdTe QDs were covered by ZIF-8. This is consistent with the results in Fig. 2A. As shown in Fig. 2C, CD/CdTe QD@ZIF-8 nanosensor had weaker emission peaks at 438 nm and 650 nm with a single excitation wavelength at 365 nm, while the maximum emission wavelengths of CDs and CdTe QDs were 430 and 640 nm, respectively. The appearance and bathochromic shift of dual-emissive fluorescent peaks demonstrated the successful combination of CDs, CdTe QDs and ZIF-8, and it meets the demand for developing ratiometric fluorescent probes.
Fig. 2 The UV-vis absorption spectra (A), FT-IR spectra (B) and fluorescence spectra (C) of CDs, CdTe QDs, ZIF-8 and CD/CdTe QD@ZIF-8. |
In addition, as shown in Fig. 3, the TEM and SEM images demonstrated that there were no significant changes between the size and shape of ZIF-8 and CD/CdTe QD@ZIF-8. This supports our supposition that CDs and CdTe QDs were successfully encapsulated in the cage construction of ZIF-8. EDS mapping images were carried out for the elemental composition tracing of ZIF-8 and CD/CdTe QD@ZIF-8, as depicted in Fig. 3E and F. After encapsuling in ZIF-8, the peaks of Cd and Te attributed to CdTe QDs appeared. Because CDs comprise chemical elements (C, N and O), which were also the components of ZIF-8, no significant changes can prove the existence of CDs occurred. The strong signal of Cu was caused by the copper nets used during the inspection. Combined with the fluorescence spectra of CD/CdTe QD@ZIF-8, we proved the successful synthesis of CD/CdTe QD@ZIF-8. CDs and CdTe QDs were enclosed in the interior space of ZIF-8, not in the external adsorption.
Fig. 3 SEM images of ZIF-8 (A) and CD/CdTe QD@ZIF-8 (B); TEM images of ZIF-8 (C) and CD/CdTe QD@ZIF-8 (D); EDS mapping of ZIF-8 (E) and CD/CdTe QD@ZIF-8 (F). |
In this paper, we designed a ratiometric fluorescent probe for determining Ag+. As shown in Scheme 1, CDs (internal standard) and CdTe QDs (fluorophore) were synthesized beforehand. Then, the nanosensors (CD/CdTe QD@ZIF-8) were developed using a facile one-pot method, which encapsulates CDs and CdTe QDs into the pore cavities of ZIF-8 (adsorbing material and separator). Because of the excellent adsorption properties of ZIF-8, Ag+ was enriched in the medium. In the presence of Ag+, Ag+ with a large size cannot pass through the shell layer and exchange with Cd2+ from CdTe, and then Ag2Te is generated, which results in the collapse of CdTe QDs and fluorescence quenching. In this nanosensor (CD/CdTe QD@ZIF-8), owing to its excellent stability and chemical inertness to Ag+, CDs play a background reference role in the sensing system, while CdTe QDs are quenched as the Ag+ reaction site. The ratio of the fluorescence intensity of CdTe QDs to CDs was measured for quantitative analysis.
As water samples from the river had different kinds of metal ions, it may affect the fluorescence of the nanosensor.38–40 In our research, several common metal ions were chosen to investigate the responses of the as-prepared nanosensor. The effects of interferents (100 μM) on the fluorescence intensity of CD/CdTe QD@ZIF-8 are demonstrated in Fig. 4A. As shown, negligible changes in fluorescence intensity were observed in the presence of other metal ions, except in Fe3+, Fe2+, Cu2+, Ag+ and Hg2+, compared to nanosensor in anion free solution. The aforementioned results can be explained as follows: in the structure of CdTe QDs, some of the particles are not perfectly coated by a shell. Hence, cations with a small size can pass through the shell layer and interact with the core. Moreover, Ag+ and Cu2+ with larger sizes cannot pass through the shell layer but strongly bind onto the surface of CdTe QDs. Compared with CdTe, Ag2Te and CuTe had extremely low solubility, which resulted in the chemical displacement of surface Cd2+ by Ag+ or Cu2+ to form Ag2Te or CuTe particles on the surface of CdTe QDs. Once Ag2Te or CuTe particles grow, the fluorescence intensity of QDs is quenched efficiently.23,41 In addition, it was reported that Fe3+ could quench the fluorescence of CdTe QDs based on a coordination reaction or fluorescence resonance energy transfer. As for Fe2+ with a strong reducing action, it is easy to be oxidized to Fe3+ in the air. It is interesting that the addition of EDTA can eliminate the effects of other metal ions except for Ag+. Therefore, EDTA was chosen to eliminate the influences brought by these interference ions.42 The results are illustrated in Fig. 4B; only Ag+ can quench the fluorescence intensity effectively after the addition of EDTA. This is attributed to the exfoliation of metal ions–EDTA chelates from the surface of the nanosensor. The results indicate that the developed nanosensor has excellent selectivity and anti-interference ability after the addition of EDTA.
Fig. 4 Selectivity of CD/CdTe QD@ZIF-8 in the presence of various potential interferents before (A) and after (B) the addition of EDTA. |
As shown in Fig. 5, the color of the CD/CdTe QD@ZIF-8 nanosensor changed gradually from red to pink along with the increase of the Ag+ concentration. Fig. 6 shows that the fluorescence intensity of the as-prepared ratiometric nanosensor at 650 nm decreased along with the increase of the concentration of Ag+, whereas the fluorescence intensity at 430 nm remained unchanged. The change of the fluorescence intensity ratio of the nanosensor at 650 nm and 430 nm (ΔF650/F430) showed a good linear relationship with the increase of Ag+ concentration in a range of 0.1–20 μM. The calibration curve is expressed by the equation ΔF650/F430 = 2.4972 × lg[Ag+] − 4.8643 with a correlation coefficient of 0.9997. The limit of detection based on 3σ/k was 1.49 nM, where σ is the standard deviation of the blank (n = 10) and k is the slope of the calibration line. As shown in Table 1, the intra-day and inter-day relative standard deviations (RSDs) of the three concentrations were all within 10%. Compared to many previously reported results, as depicted in Table 2, the present study using CD/CdTe QD@ZIF-8 nanosensor has a wider linear range and more excellent LOD for Ag+ determination. The outstanding sensitivity of the developed sensor is attributed to the excellent adsorption capacity of the ZIF-8 shell in CD/CdTe QD@ZIF-8. In short, the above results indicate that the probe conducted in this study can meet the needs of the determination of Ag+ in practical samples.
Fig. 6 The linearity relationship between fluorescence intensity value of (ΔF650/F430) and different concentration of Ag+. Inset: calibration curve of Ag+ detection in the range of 0.1–20 μM. |
concentration of Ag+ (μM) | Intra-day (μM) | RSD (%) | Inter-day (μM) | RSD (%) |
---|---|---|---|---|
0.2 | 0.204 | 5.7 | 0.196 | 2.3 |
0.194 | 0.204 | |||
0.182 | 0.204 | |||
1 | 0.964 | 4.8 | 1.024 | 9.0 |
0.951 | 0.964 | |||
0.882 | 1.147 | |||
16 | 15.416 | 2.7 | 16.334 | 3.0 |
14.674 | 15.416 | |||
15.284 | 15.985 |
Probe | Linear range (μM) | LOD (nM) | References |
---|---|---|---|
N-GQDs | 0.2–40 | 168 | 2 |
MnO2 nanosheet–DNA complex | 30–240 | 9.1 | 16 |
GSH@CdTe QDs | 0.02–0.2 | 1.3 | 21 |
MPA stabled CdTe QDs | 0.4–3.2 | 41.06 | 23 |
Dansyl-peptide | 1–5 | 80 | 43 |
Cysteamine capped CdS QDs | 0.1–1.5 | 68 | 44 |
DNA–Ag nanoclusters | 0.05–0.50 | 10 | 45 |
DNA-functionalized AuNPs | 0.05–0.75 | 9.5 | 46 |
GQDs and OPD | 0–115.2 | 250 | 47 |
CD/CdTe QD@ZIF-8 | 0.1–20 | 1.49 | This work |
To verify the feasibility of the proposed method, the prepared nanosensor was applied to detect Ag+ using the standard addition method. The results are presented in Table 3. The recoveries were in the range of 88.29–90.39% with RSDs less than 1%. The results indicate that the as-prepared ratiometric fluorescent probe possesses viability for the determination of Ag+ from real samples.
Sample | Spiked (nM) | Found (nM) | Recovery (%) | RSD (%) |
---|---|---|---|---|
Lake water | 0 | 152.78 | — | — |
150 | 288.36 | 90.39 | 0.52 | |
300 | 418.90 | 88.70 | 0.35 | |
450 | 550.11 | 88.29 | 0.18 |
This journal is © The Royal Society of Chemistry 2022 |