Boxin
Zhang
d,
Indu
Aravind
a,
Sisi
Yang
a,
Sizhe
Weng
c,
Bofan
Zhao
c,
Grace
Johnson
ef,
Lucas
Brown
ef,
Jason
Olfert
g,
Heejung
Jung
ef and
Stephen B.
Cronin
*abc
aDepartment of Physics and Astronomy, Los Angeles, CA 90089, USA. E-mail: scronin@usc.edu
bDepartment of Chemistry, Los Angeles, CA 90089, USA
cMing Hsieh Department of Electrical Engineering, Los Angeles, CA 90089, USA
dMork Family Department of Chemical Engineering and Materials Science, University of Southern California, Los Angeles, CA 90089, USA
eDepartment of Mechanical Engineering, Riverside, CA 92521, USA
fCollege of Engineering-Center for Environmental Research and Technology (CE-CERT), University of California, Riverside, Riverside, CA 92521, USA
gDepartment of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada
First published on 29th September 2023
This study evaluates the beneficial effects of discharging nanosecond pulse transient plasma (NPTP) in a coaxial electrostatic precipitator for capturing nanoscale soot particles (∼50 nm) produced by an ethylene flame. Here, the nanoscale soot particles are collected using two different reactor geometries: a 3′′ diameter reactor with a mean flow velocity of 1.2 m s−1 and a 1.5′′ diameter reactor with a mean flow velocity 1.5 m s−1, corresponding to volumetric flow rates of 11.5 CFM and 3.6 CFM, respectively. The nanosecond high voltage pulses (+20 kV, 20 ns, 800 Hz) are applied in conjunction with DC bias voltages. While nearly 100% collection efficiency can be achieved without NPTP at sufficiently high DC voltages (|VDC| > 14 kV), this drops below 50% for lower DC voltages (|VDC| < 10 kV). With NPTP, we observe substantially enhanced remediation (up to 23×) at lower DC voltages (|VDC| < 10 kV) due to the enhanced ion density produced by the plasma. For DC-only electrostatic precipitation, the charging of soot particles takes place via a DC corona, whose ion density is several orders of magnitude lower than that of the NPTP, which produces a streamer discharge due to the fast rise times of the nanosecond pulses (i.e., dV/dt ∼ 1012 V s−1). High speed imaging of the plasma emission profile indicates that ion densities 106 times higher are achieved with the nanosecond pulsed plasma, as compared to that of the DC corona. At lower DC voltages (i.e., |VDC| < 10 kV), the charging of soot particles is a key factor limiting the DC-only remediation efficiencies, and NPTP provides a way to mitigate this limitation.
Environmental significanceThe remediation of combustion generated particles (i.e., soot or black carbon) produced by internal combustion engines is important due to their adverse health effects and their effects on climate change. There are currently no after treatment systems for controlling particulate emissions from medium and large ship engines. These ships emit soot at and near port, as well as in the open ocean, resulting in poor air quality near port areas and global climate change. We are reporting up to 23× enhancement in the collection efficiency (% remediation) of soot particles with nanosecond pulse transient plasma over a wide range of DC bias voltages from −15 kV to +15 kV. In the midst of accelerating climate change and global warming, our work in this field adds a significant scientific contribution to the ever-demanding search for cleaner automobile and industrial emissions. |
Electrostatic precipitators (ESPs) are widely used to treat large volumes of particle laden flow.18 Most coal-fired power plants are equipped with ESPs to reduce emissions of particulates called fly ash. ESPs generally require a very large footprint and path length, which can be problematic for mobile sources.19 In conventional ESPs, a corona discharge produced at high DC voltages generates ions that charge particles in the exhaust stream.20 These charged particles are then swept out to the collecting electrodes by the electrostatic force of the DC voltage, thus, precipitating the particles out of the gas phase.21 ESPs have not been adopted to remove diesel particulates from on-road diesel engines, as they require a long path and large device sizes to achieve a high enough collection efficiency.22 While DC coronas in conventional ESPs are very effective in charging large particulates (i.e., larger than 1 μm), they do a relatively poor job of charging sub-micron sized particles (e.g., diesel particulates are typically ∼100 nm).23 Also, ESPs are not appropriate for treating dynamically changing exhaust emissions, such as diesel exhaust emissions for on-road vehicles. However, this limitation can be overcome if higher concentrations of ions can be generated. In a conventional ESP, a constant voltage is used to charge the particles (via corona discharge) and provide the electrostatic force needed to sweep them out to the collecting electrode. This DC corona discharge is inherently unstable, as the ionization threshold and arcing limit are often very close, leaving a narrow range of operation. At high enough voltages, dielectric breakdown occurs, resulting in the formation of a highly conducting arc (see Fig. S1 in the ESI†), which causes the electrostatic field between the two electrodes to collapse, terminating the electrostatic precipitation process. The arcing threshold (i.e., dielectric breakdown) depends strongly on temperature,24 which is particularly problematic for dynamically changing exhaust emissions that can be inhomogeneously distributed along the reactor length. Nanosecond high voltage pulses provide a way around this arcing threshold, enabling substantially higher peak fields to be achieved without arcing. With higher ion concentrations, more compact ESPs can be designed to effectively capture sub-micron particles and provide increased stability over a wider range of operating conditions. As such, it is important to develop new strategies and systems that can avoid instabilities related to arcing.
In the work presented here, we report the effect of transient plasma discharge on the collection efficiency of electrostatic precipitation of soot particles over a wide range of applied DC voltages based on particle size distribution measurements. The particle effective density, with and without transient nanosecond pulse plasma, was also measured to determine the change in particle mass distribution. Lastly, high speed imaging of the plasma distribution profile was performed on the transient plasma and DC corona in order to compare their relative ion densities.
Fig. 1 Schematic diagram of the plasma-enhanced electrostatic precipitator (PE-ESP) soot remediation system and measurement configuration. |
Particle aerodynamic number-size distributions are measured using a Dekati ELPI+ aerosol particle size spectrometer (Model 2E10-10) over a range from 6 nm to 10 μm. Particle mobility number-size distributions were measured with a TSI Scanning Mobility Particle Sizer (Model 308200), which consists of a differential mobility analyzer (DMA, TSI Model 3080) and a condensation particle counter (CPC, TSI Model 3750). The DMA was set to a resolution of 0.3 nm, and the range of the measurement is 9.65 to 421.7 nm. The collection efficiency is calculated as the ratio of the total particle concentration (number or mass) with the ESP on divided by the particle concentration with the ESP off. The number concentrations are determined by integrating the particle number distribution over the range of each instrument. The particles generated by the flame were less than 300 nm (in either mobility or aerodynamic diameter).
The mass concentration of the aerosol is found by converting the number-size distributions to mass-size distributions and integrating. The relationship between particle size and particle mass (often expressed as the ‘effective density’ as a function of mobility diameter) is measured using a DMA (TSI Model 3080), which classifies particles by electrical mobility, in series with a centrifugal particle mass analyzer (CPMA, Cambustion Ltd),26 which classifies particles by their mass-to-charge ratio, and a CPC (TSI Model 3750), as shown in Fig. 1. Details of the DMA-CPMA-CPC system and the effective density measurements of the soot are discussed in detail in Section S1 of the ESI.†
Fig. 3a shows the particle number-based collection efficiency observed with the 1.5′′-diameter reactor plotted as a function of DC voltage for DC-only and DC with nanosecond pulse transient plasma discharge using the ELPI+ particle spectrometer. Looking first at the DC-only data around zero bias voltage, we see the collection efficiency increasing monotonically under both positive and negative applied potentials, reaching around 40–50% remediation up to 10 kV for positive bias DC voltage and down to −9 kV for negative bias DC voltage. This low-bias remediation occurs because a fraction of the soot particles entering the reactor are already charged bipolar (i.e., both positively and negatively charged particles) by chemical ions from the ethylene diffusion flame. Thus, for either negative or positive applied voltages, only half of the particles (i.e., the charged fraction) are remediated under DC-only conditions.27 DC voltages VDC < −10 kV lie above the threshold for ionization (i.e., formation of a corona discharge), and the remediation rapidly jumps up to nearly 100% with increasing DC voltage as the DC corona discharge generates ions that impart charge to the soot particles. The data taken with transient plasma discharge (red data points) exhibit a roughly 2–3 fold enhancement in the remediation over the entire voltage range from −8 kV to +10 kV. This enhancement is due to the high concentrations of ions created by the high voltage nanosecond pulse discharges. High concentrations of both positive and negative ions may increase the average absolute charge per particle in both polarities, increasing particle electrical mobility. Originally, we had hoped that the plasma would oxidize/vaporize the soot particles. However, this does not appear to be the case, as evidenced by the poor remediation efficiency observed without the DC bias (i.e., plasma only). Instead, the main effect of the plasma is to increase the ion density and, hence, charge per particle, thus, facilitating/enhancing the electrostatic precipitation process.
Fig. 3b shows the corresponding data taken with the 3′′-diameter reactor. Looking first at the DC-only data (black data points), we observe the same low-bias voltage dependence in which a fraction of soot particles is charged (imparted during combustion and subsequent soot formation process), resulting in a monotonically increasing dependence of the remediation on DC voltage that reaches a level of approximately 50% remediation. For high voltages |VDC| > 14 kV that lie above the ionization threshold, the DC corona generates a substantial amount of charge, which is imparted to the soot particles resulting in highly efficient electrostatic precipitation. The data taken with transient plasma discharge (red data points) again show a substantial enhancement in the remediation percentage over the entire voltage range from −12 kV to +14 kV. This enhancement is due to the large amount of charge generated by the high voltage nanosecond pulse plasma that imparts a large amount of charge to the soot particles, facilitating more efficient precipitation to the sidewalls of the reactor. There is, however, a slight drop in the plasma-enhanced remediation over the range from −4 kV to −8 kV due to the partial cancelation of the positive nanosecond pulse voltage by the negative applied DC voltage.
Fig. 4 compares the particle number and particle mass distributions under several test conditions measured using SMPS spectroscopy. The particle mass distributions were determined using the particle effective density (Fig. S3†) along with their number distribution. The particle number mean diameter is centered around 60 nm for all cases, while the particle mass mean diameter is centered around 120 nm. Table 1 summarizes the remediation efficiencies by number and mass obtained by integrating the distributions plotted in Fig. 4. The particle effective density with pulser on was used for −14 kVDC because of the expected ozone production due to the corona discharge, while the baseline particle effective density was used for −2 kVDC due to the absence of corona discharge and corresponding absence of ozone. It is well known that ozone is produced by the plasma, however, for engine exhaust ozone is consumed rapidly by NO. As such, we typically do not observe any ozone in real exhaust applications. The remediation efficiencies obtained by mass and number were in close agreement with each other except in two cases: 0.2 kHz pulser only and −2 kVDC only. The size-dependent, number-based remediation efficiencies obtained under 0.8 kHz pulse frequency and 2 kVDC bias conditions are plotted in Fig. 5. The collection efficiency profile from 16 nm to 200 nm exhibits a diameter dependence similar to a previous study showing minima around 75 nm.29 In this previous work, Ehara et al. explained the decrease in collection efficiency by re-entrainment of particles. However, the authors do not fully understand the sharp decrease in collection efficiency below 16 nm and indicate that further investigation is necessary. The diameter dependence of the remediation obtained with the ELPI particle size spectrometer are plotted in Fig. S4–S6 of the ESI.†
By number | By mass | |
---|---|---|
0.2 kHz NPTP | 6 | 11 |
0.8 kHz NPTP | 12 | 18 |
0.8 kHz NPTP – 2 kVDC | 63 | 63 |
0.8 kHz NPTP – 14 kVDC | 100 | 100 |
−2 kVDC | 8 | 0 |
−14 kVDC | 99 | 99 |
Fig. 5 Plots of the particle remediation by number and by mass observed under 0.8 kHz NPTP – 2 kVDC. |
Our previous work28 reported the use of plasma-enhanced electrostatic precipitation in diesel engine exhaust under engine relevant conditions. In the work presented here, we perform high speed optical imaging of the transient plasma, DC corona, and transient plasma + DC bias. This optical study demonstrates ion density enhancement via transient plasma and provides a way to explain the large increase in the collection efficiency of soot particles at low VDC with plasma. We also investigate a wide range of VDC (i.e., −18 kV to +18 kV) for a full dataset of collection efficiency at various VDC with and without plasma, whereas our previous paper only studied a few DC voltages. In particular, this study provides an important comparison of the NPTP under positive and negative applied bias voltages. Lastly, the soot particles used in this study were produced by a flame burner rather than a diesel engine, which eliminates several effects associated with moisture, NO and high temperatures.