Muhammad
Sher
a,
Luqman Ali
Shah
*a,
Jun
Fu
b,
Hyeong-Min
Yoo
c,
Riaz
Ullah
d and
Mohamed A.
Ibrahim
e
aPolymer Laboratory, National Centre of Excellence in Physical Chemistry, University of Peshawar, 25120, Pakistan. E-mail: luqman_alisha@uop.edu.pk; Luqman_alisha@yahoo.com; Fax: +92-91-9216671; Tel: +92-91-9216766
bKey Laboratory of Polymeric Composite and Functional Materials, School of Materials Science and Engineering, Sun Yat-sen University, Guangzhou 510275, China
cSchool of Mechanical Engineering, Korea University of Technology and Education (KOREATECH), Cheonan 31253, Republic of Korea
dDepartment of Pharmacognosy, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia
eDepartment of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
First published on 18th September 2024
Conductive hydrogel-based soft devices are gaining increasing attention. Still, their dependence on water makes them susceptible to freezing and drying, which affects their long-term stability and durability and limits their applications under subzero temperatures. Developing hydrogels that combine exceptional strength, high strain sensitivity, anti-freezing properties, synchronous sensing, durability, and actuating capabilities remains a significant challenge. To overcome these issues, a universal solvent replacement strategy (USRS) was adopted to fabricate anti-freezing and anti-drying organohydrogels with ultra stretchability and high strain sensitivity in a wide temperature range. Ethylene glycol (Eg) and glycerol (Gl) were used as secondary solvents to replace water (primary solvent) from the hydrogel network. Due to the strong hydrogen bonding capabilities of Eg and Gl with water and the hydrogel network, the organohydrogels formed show resistance to freezing and drying. This allows the organohydrogels to maintain conductivity, sensitivity, stretchability, and durability under subzero temperatures. The developed organohydrogels display remarkable stretchability (850%), good electrical conductivity (0.45 S m−1), exceptional anti-freezing performance below −90 °C and very high sensitivity (GF = 10.14). Additionally, the strain sensor demonstrates a notably wide strain range (1–600%) checked within the temperature range of −15 °C to 25 °C. It also effectively monitors various human movements with differing strain levels, maintaining good stability and repeatability from −15 to 25 °C. It is also believed that this strain sensor can work efficiently above and below the mentioned temperature range. This study introduced a straightforward approach to developing conductive organohydrogels with outstanding anti-freezing and mechanical properties, demonstrating significant potential for use in wearable strain sensors and soft robotics.
Soft robotics is an emerging field that involves the design and development of robots. Strain sensing is a vital feature of soft robots, allowing them to establish a tactile interface resembling human skin when interacting with their surroundings. To meet soft robot compliance and morphology needs, sensing materials must possess softness and stretchability to minimize interference with the robot movements.7 Traditional practice involves engineering nano-materials like low-dimensional carbon materials, metal nanowires, and silicon nano-ribbons on elastic substrates to create stretchable strain sensors for robot incorporation, but they usually suffer from low mechanical performance.7
This issue has been resolved using intrinsically stretchable materials that offer a straightforward solution, boasting simple fabrication processes, affordability, strong mechanical resilience, and a high device density.8 In this regard, hydrogels, three-dimensional (3D) polymeric networks, can hold substantial amounts of water without leaking primarily due to their 3D structure. This feature equips them with advantageous properties akin to living tissues, making them highly valuable for diverse applications in biomedicine and soft electronics.9,10
In the past decade, scientists have greatly improved the weak areas of hydrogels. For example, various approaches have been investigated to tackle the issue of weak mechanical properties. These include the development of double-network structures, enhancing crosslinking density, employing multi-functional crosslinkers, and introducing an anisotropic configuration. In particular, double-networked (DN) hydrogels, comprising a rigid network and a ductile matrix, demonstrate improved mechanical strength, resilience, and functional attributes compared to their single-networked counterparts.
Recent reports have also showcased hydrogel-based strain and pressure sensors that boast exceptional stretchability. For example, Yazdani et al. developed a robust hydrogel by combining lauryl methacrylate, acrylamide, and sodium alginate through a cross-linked network for ionic skin and human motion detection.11 Ullah et al. have developed a mechanically strong hydrogel with fracture stress and strain that reached 0.5 MPa and 401%, respectively, having gauge factor values 8.2.12 Similarly, in our previous work, we developed hydrogels for flexible and artificial epidermis with an enhanced mechanical performance of 1100% and a fracture strain of 661 kPa with high sensitivity having a gauge factor value of 28.8.9 However, hydrogels unavoidably solidify below-freezing temperatures, resulting in stiffness, fragility, and loss of conductivity.13,14 Furthermore, these strategies need to be revised to control excess water, leading to environmentally unstable hydrogels that frequently need to meet the criteria for long-term durability. Hence, the utilization of hydrogel-based devices is impeded in low-temperature environments. Even under room temperature or higher, hydrogels inevitably experience dehydration through water evaporation.15,16 The inherent problems of freezing and drying lead to loss in flexibility, stretchability, conductivity, and other properties in water-based hydrogels, significantly undermining their stability and durability, and the potential applications of devices they are used in.17,18
Eg and Gl, well-known humectant and anti-freezing agents used in industry, have high boiling points and low volatility at room temperature compared to water. Replacing water with ethylene glycol and glycerol endowed the hydrogels with enhanced durability, anti-drying, and anti-freezing properties.19,20 They prevent water from freezing by creating strong hydrogen bonds with water molecules while simultaneously breaking the hydrogen bonds between water molecules.8,13 Notably, by adjusting the Eg and Gl concentration in the organohydrogels, the freezing point can be lowered to as much as −40 °C, significantly below the freezing points of pure Eg and water.20,21
Herein, we describe a straightforward USRS for creating strong, ultra-stretchable, and stable organohydrogels with conductive, anti-freezing, and anti-drying characteristics for soft robotics and human–machine interaction. Hexadecyltrimethylammonium bromide (HDAB) was dissolved in distilled water to produce a micelle structure in which hydrophobic monomer lauryl methacrylate (LM) stabilizes itself. Then, acrylamide (Am) and LM copolymer were grafted onto the agar (Ag) chain using ammonium persulphate (APS) as a thermal initiator. Incorporating Ag improves the hydrogel's mechanical characteristics and makes it more challenging. Moreover, the synthesized hydrogels were successfully converted into organohydrogels through USRS using different Eg and Gl concentrations in individual states and binary solution form. The obtained anti-freezing organohydrogels displayed enhanced stretchability (up to 850% strain), anti-drying, and strain-sensing capability at −15 °C. Thus, the strain sensors based on organohydrogels can be applied in soft robotics and human–machine interaction technologies with great stability, high sensitivity (GF = 10.14), wide strain range (1–600%), and a wide temperature range.
(1) |
To subject the sensor to desired strains during the electromechanical test, the ends of the samples were secured onto the two-electrode system using a stretching stage labeled carefully for each desired strain in increasing order.
The electromechanical properties of the organohydrogel sensors for low-temperature strain sensing were investigated immediately upon its removal from the −15 °C environment. After removing it from the subzero temperature, we performed only one test each time and stored it again for one hr. In this process, we alternatively used five samples of the same composition and equal dimensions. A similar configuration was utilized to study human motion monitoring, sensitivity (gauge factor), and pressure sensing.
Similarly, the viscoelastic properties of the designed hydrogels and organohydrogels were examined using an Anton Paar rheometer (Physica MCR 301) equipped with a 25 mm diameter measuring probe. Amplitude sweep tests were conducted over a strain range of 0.01 to 1000% at a constant frequency of 10 rad s−1, while frequency sweep experiments covered frequencies from 0.1 to 100 rad s−1; throughout the rheological analysis, the temperature was maintained at 25 °C. Percentage changes in storage modulus were calculated using eqn (2).25
(2) |
The conductivity of the organohydrogels was checked by using an LCR machine. A piece of known dimension organohydrogel was investigated for RS (series resistance) value by connecting it in the two electrodes of the device. The values were utilized to get the conductivity of the organohydrogels using eqn (3).25
(3) |
The water retention capability of the organohydrogels was validated through a comparative study with a hydrogel. In this study, samples S1, S2, S3, and S6 were kept at room temperature (RT) and pressure and relative humidity (RH) of 58% in an open environment. Over the course of two months, the water loss was monitored, and their water retention capabilities were ultimately compared.
Differential scanning calorimetry (DSC) curves of the samples were acquired using a DSC-204 F1 instrument from Netzsch, Germany in the temperature range of 25 to −90 °C.
Similarly, the addition of Ag to the solution led to the formation of stable hydrogels due to its capability to form physical cross-linking (hydrogen bonding) with both LM and Am due to numerous numbers of active sites on its chain, as shown in Fig. S1 (ESI†) and reported in previous literature.29 Furthermore, the stability can also be attributed to the capability of the Ag to link to the hydrogel structure from different sites. The addition of CoCl2·6H2O imparts conductivity to the hydrogels and makes it best fit for sensing applications. A sample without Ag was synthesized to investigate the effect of Ag on the hydrogels mechanical performance.
Similarly, the organohydrogels were prepared by following the USRS driven by the concentration difference, as shown in Fig. 1 and reported in previous literature.8 The as-fabricated water-based hydrogels were directly immersed in an Eg and Gl solution to exchange water molecules from the hydrogel network with an outside Eg and Gl solution. Due to the difference in concentration, the molecular exchange occurred swiftly until reaching equilibrium. Consequently, the initial water-based hydrogels were transformed into organohydrogels using Eg and Gl in the individual states and a binary solvent, displaying enhanced capabilities to resist freezing and dehydration. To explore the impact of solvents on the anti-freezing properties of the product material, identical batches of hydrogels were submerged in five distinct solutions. These solutions comprised 100 wt% Eg, 100 wt% Gl, 50 wt% of Eg/Gl each, 30 wt% Eg + 70 wt% Gl, and 30 wt% Gl + 70 wt% Eg, for equal durations, yielding respective samples labeled S1 through S5. Similarly, a sample containing only water (not soaked) is named as S6, while a sample without Ag was prepared and coded as sample S0.
Conversely, all the other samples had almost frozen up after 24 hours of treatment and could not withstand such large deformations. This suggests the importance of Eg and Gl solvent and its efficiency in imparting anti-freezing characteristics in the organohydrogels reported in previous literature.30 It has also been clear that the lowest freezing point of the organohydrogels is obtained when the hydrogel was dipped in 100% Eg and 100% Gl for 1 hour.8 By contrast, hydrogels dipped in low concentrations of Eg and Gl solution could not achieve the required amount of solvent replacement. The competition between the solvents, combined with their diluted effective concentrations, reduces their ability to efficiently penetrate the hydrogel matrix and replace the internal water content, leading to incomplete solvent replacement. Furthermore, the incomplete swelling dynamics results in only a small amount of solvent replacement leaving the hydrogel matrix less modified than intended. Hence, samples S1 and S2 demonstrate superior anti-freezing capacity compared to S3, S4, and S5. Fig. S2 (ESI†) presents images comparing the stretching performance of the hydrogels and organohydrogels at room temperature and after storing at −15 °C for two hours. It is clear from the images in Fig. S2(A, a) (ESI†) that the stretching ability of the hydrogels has decreased after keeping at subzero temperature; conversely, the stretching performance of samples S1 and S2 is not as such affected by storing at subzero temperature (Fig. S2(B, b and C, c), ESI†). These samples can maintain their ability to stretch at various strains even after being stored at −15 °C for 24 hours, showcasing remarkable resilience under subzero conditions. While our current experimental setup registers −15 °C as the minimum temperature, there's a possibility that the organohydrogels could resist freezing even at lower temperatures. Therefore, employing the solvent replacement strategy offers a convenient avenue for adjusting the freezing resilience of organohydrogels by manipulating the concentration of antifreeze agents. The significantly enhanced anti-freezing capability observed in the resulting organohydrogels also suggests successful modification of Eg and Gl within the hydrogels through the USRS. Moreover, we conducted a thorough examination of the anti-freezing characteristics of the hydrogels and organohydrogels by analyzing the DSC curves of the samples, as shown in Fig. 2e. The analysis revealed a broad and long crystallization peak for samples S4 and S6. This broader peak suggests that the samples do not crystallize simultaneously at a specific temperature but rather over a range of temperatures with maximum crystallization at the peak temperature value. Sample S6 demonstrated some antifreeze behavior, with a crystallization temperature of −5 °C, attributed to the presence of CoCl2·6H2O. Similarly, samples S3, S4, and S5 showed peaks at −16.6 °C, −57.4 °C, and −24.4 °C, respectively, indicating their antifreeze properties. The broader peak in sample S4 suggests that 70% Gl can impart improper crystallization behavior, which is over a range of temperatures with the maximum at −57.4 °C. In contrast, there were no obvious peaks for samples S1 and S2 within the provided temperature range, indicating that these samples can function below −90 °C.
Furthermore, the hydrogen bonding between the water molecules is disturbed by replacing water with Eg or Gl. By comparing the mechanical strength of the organohydrogels, the breaking point of sample S2 is at 900% strain, whereas that of sample S1 is at 790% strain. The greater reduction in both tensile stress and strain for S1 is attributed to the fewer active sites on Eg compared to Gl, as well as the differing swelling ratios in the solvent used. Furthermore, the existing van der Waals forces among Ag, water, and the hydrogel network is disturbed, and it could not regain its strength after replacing water with Eg.32Fig. 3b shows a comparative study of the toughness and elastic modulus of the synthesized materials. It can be deduced that the incorporation of the Ag into the hydrogels and then the subsequent replacement of the solvent with the Gl had a profound effect on the material toughness, and its performance increased significantly.
On the contrary, the replacement of water with Eg negatively affected the material performance in terms of toughness and elastic modulus. Similarly, Fig. 3c shows that sample S2 has the highest stiffness, which increases from 191 kPa to 447 kPa, indicating that the material displays higher resistance to deformation, showing the effect of Gl on the synthesized material. This enhancement in the material stiffness is because of the physical cross-linking of Ag and Gl due to numerous active sites on their side chain. Fig. 3d shows the Young's modulus of the material, which is highest (1.87 kPa) in the case of sample S2. Based on these studies, organohydrogel S2 was further considered for tensile cyclic loading–unloading testing to check its anti-fatigue performance. Fig. 3e shows a series of ten stretching cyclic tests, which shows that the hysteresis curves almost perfectly overlap after the 1st cycle, showing the remarkable fatigue resistance of the organohydrogel S2. This is also depicted in Fig. 3f, which suggests how the organohydrogel S2 responds to deformation forces during the ten consecutive cyclic tests. Fig. 3g indicates an energy dissipation mechanism in the organohydrogels, the primary source of which is hydrogen bonding. During the deformation process, these dynamic and reversible physical bonds, which also function as sacrificial bonds, effectively disperse mechanical stress and energy.33
Herein, we have kept a small piece of samples S1, S2, S3, and S6 with known dimensions and weight in an open environment at RT, RH of 58%, and noted the weight loss in each case over 8 days and extended this duration for two months. The weight loss in the case of sample S6 was found to be 22.6%. Similarly, the weight loss was 11.3%, 8%, and 13.6% in the case of sample S1, sample S2, and sample S3, respectively. It is clear from Fig. 4a, that the sample without soaking lost its stretchability, became hard and brittle, and lost its original color after some days. Furthermore, a higher water retention capacity was noted in the case of S2 because of more hydrogen bonding capability due to the creation of numerous numbers of active sites when replaced with water. Similarly, the weight loss after the 4th day was negligible and when the samples were investigated after two months, no significant water loss was observed in the case of samples S2 and S3, showing the environmental resilience and durability of these samples, as shown in Fig. 4(b) and (c).
Similarly, the strain sensing at different stretched levels for S6, S1, and S2 at −15 °C is shown in Fig. 6(a)–(i). It can be deduced that the hydrogel network facilitated the conduction of Co2+ and Cl− ions when an electric potential is applied, allowing ions to move through the hydrogel pores, resulting in ionic conductivity. Stretching the hydrogels enlarged the ion conduction pathway, increasing resistance and reducing LED brightness, as shown in Video S3 (ESI†). Releasing the stress restored the hydrogels to its original length, intensifying LED brightness and showcasing remarkable strain sensitivity and reversibility.
Additionally, a range of strain levels were applied to the organohydrogels after storing at −15 °C, taking one reading each time and then storing again for 1 hour. We systematically performed different stretching and release cycles through auto-lab by performing chronoamperometry at an applied potential of 1 V. Fig. 7(a) and (b) indicate that as the percent strain rises from 1% to 50% and 10% to 600%, resistance concurrently increases. This trend suggests that the pores within the hydrogel constrict as their length increases, making the movement of ions more challenging. This trend also shows the excellent sensitivity of the fabricated organohydrogels towards both small and large strains (1% and 600%), respectively. The response time of the as-fabricated hydrogels is found by conducting rapid stretching and subsequent relaxation experiments at a 400% strain level. The results revealed response and recovery times of 0.1 seconds (100 milliseconds) and 0.08 seconds (80 milliseconds), respectively (Fig. 7c), which surpasses those of other hydrogels and organohydrogels previously synthesized.36,37 This swift reaction to strain indicates that the synthesized hydrogels exhibits robustness and retain elastic energy efficiently even under low dissipation.
Consequently, it can swiftly rebound when subjected to stretching or compression. To further elucidate the stability of the organohydrogels, multiple cycles and slow-fast stretching were performed. Fig. 7d shows the organohydrogels response towards multiple cycles, during which 200 cycles were performed by continuously stretching and relaxing the organohydrogels for 200 seconds at 400% strain. There is no significant current drop observed, which shows the remarkable anti-fatigue resistance of the as-fabricated organohydrogels. The material stability was further confirmed by taking 500 cycles at 200% strain, and again no significant current drop was observed (Fig. S5, ESI†). In the same way, slow fast stretching was performed at different strain levels as shown in Fig. 7(e) and (f) −15 °C. This also suggests the stability and reproducibility of the material as the peaks generated are the same every time.
Furthermore, the strain sensitivity was also analyzed using the gauge factor (GF), a crucial quantitative measure for assessing material strain sensitivity. GF is determined by the formula previously used in the literature as (ΔR)/(R°)/ε. Fig. 7(g) and (h) illustrate that the organohydrogels exhibited an outstanding linear relationship between the relative change in resistance (ΔR)/(R0) and strain.
The linearity, as indicated by the correlation coefficient (R2), achieved a value of 0.99. The relative resistance (RR) was determined using ΔR/R0 (%) = 1.41119ε + 0.00535ε2 and then a linear fit was applied to calculate the GF, as shown in Fig. 7g.
Fig. 7h indicates that as strain increases, the GF enhances and at an applied strain of 700%, the calculated GF value obtained was 10.14, which exceeds those reported in previous studies underscoring the compassionate nature of the organohydrogels.38,39 All these findings suggest that the as-fabricated organohydrogel is a good fit for cyclic activities, highlighting its superior strain sensitivity under subzero temperatures. The key parameters of the current research compared with the most recent one of the same type are presented in Table S1 (ESI†). It can be deduced that although some of the synthesized materials have amazing sensitivity and conductivity, their working range is limited to RT. Some of them can work under a wide range of temperatures, but their sensitivity and stretchability are reduced.
However, the prevalent issue with hydrogels is their susceptibility to drying and freezing, particularly in low-temperature environments, leading to inactivation. Hence, there is a pressing need to innovate and develop a new breed of antifreeze gel materials capable of withstanding harsh cold conditions and resisting evaporation.43 Herein, the synthesized organohydrogels have remarkable anti-freezing and anti-drying capabilities, heightened strain sensitivity, good electrical stability, and robust mechanical properties. All these properties make the designed organohydrogels suitable for flexible wearable electronics, wearable robotics, and human motion detection. To perform some human motion tests, a circuit was devised by integrating an organohydrogel strip with an automated laboratory system. The organohydrogel strip, once connected, was affixed to various mobile joints on the body using scotch tape. This setup enabled detection at both singular and varied angles for comprehensive testing. Fig. 8a shows the finger bending response at a single angle. As the finger flexed to a specific degree, the organohydrogels underwent stretching, causing a temporary decrease in the current. Upon the finger returning to its original position, the current drop normalized accordingly.44 Similarly, Fig. 8b shows the response of the organohydrogels to the finger movement across various angles at subzero temperature. It was observed that with an increase in the finger angle, there is a corresponding increase in the percent relative resistance. Upon the finger restoration to its initial orientation, the percentage relative resistance reverted to its baseline level.
In the same way, Fig. 8c shows the response of organohydrogels to the elbow movement at various angles. This shows that as the elbow is bent for the 2nd time to the same angle, the current drop is similar which confirms the stability and reproducibility of the organohydrogels. Fig. 8d shows the response of the organohydrogels towards elbow movements at one specific angle. The organohydrogel sensitivity was further illustrated by affixing it onto the arm muscles. This resulted in distinct current–time peaks during muscle contraction and relaxation, as depicted in Fig. 8e. The organohydrogel response during handshaking can be shown in Fig. 8f, which shows that as the volunteers shake hands, the current drop occurs for a short period and gets normalized as the volunteers let go of each other's hands.
Furthermore, the meticulously designed organohydrogels demonstrates precision by detecting human voice, coughing signals, minute pressure through pen touch, and pressing keys on a keyboard even at subzero temperatures. As depicted in Fig. 9a, each time the volunteer coughs, the organohydrogels deliver a distinct signal, showcasing its reliable performance. Similarly, when the organohydrogels were affixed to the volunteer's vocal cords, it consistently detected the word “anti-freezing” with a specific signal upon pronunciation, as shown in Fig. 9b. The organohydrogel's ability to detect even the slightest pressure is demonstrated in Video S4 (ESI†). When the volunteer lightly touches the organohydrogel with a pen tip, a small signal is generated, affirming that the current drop occurs even with a minuscule touch to the organohydrogel (Fig. 9c). To ensure the reliability of our findings, the organohydrogel was rigorously tested. In one such test, the organohydrogel was affixed to the volunteer's forefinger, and their response to pressing the keyboard keys was analyzed. Fig. 9d presents the response when the volunteer presses the space button on the keyboard. These tests were repeated with five different segments of the same sample of S2, with each segment stored at −15 °C for 1 hour after each test, to mimic real-world conditions and verify the organohydrogel's consistent performance.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4ma00725e |
This journal is © The Royal Society of Chemistry 2024 |