Nicole
Lecot
*ab,
Marcelo
Fernández-Lomónaco
c,
Hugo
Cerecetto
b,
Juan Pablo
Gambini
d,
Pablo
Cabral
b and
Romina
Glisoni
*e
aLaboratorio de Técnicas Nucleares Aplicadas a Bioquímica y Biotecnología, Centro de Investigaciones Nucleares, Facultad de Ciencias, Universidad de la República, 11400 Montevideo, Uruguay. E-mail: nlecot@fcien.edu.uy
bÁrea de Radiofarmacia, Centro de Investigaciones Nucleares, Facultad de Ciencias, Universidad de la República, 11400 Montevideo, Uruguay
cLaboratorio de Experimentación Animal, Centro de Investigaciones Nucleares, Facultad de Ciencias, Universidad de la República, 11400 Montevideo, Uruguay
dCentro de Medicina Nuclear, Hospital de Clínicas, Facultad de Medicina, Universidad de la República, Av. Italia s/n, 11600, Montevideo, Uruguay
eInstituto de Nanobiotecnología (NANOBIOTEC, UBA-CONICET), Department of Pharmaceutical Technology, Faculty of Pharmacy and Biochemistry, University of Buenos Aires, Buenos Aires, Argentina. E-mail: rglisoni@ffyb.ubar.ar; romy.glisoni@gmail.com
First published on 5th February 2024
Indocyanine green (ICG) is an FDA-approved near-infrared (NIR) dye used as a contrast agent for medical diagnosis in such techniques as image-guided surgery (IGS) and IGS-supported mapping for sentinel lymph node biopsy (SNLB). However, there are numerous disadvantages to its use in clinical applications: (i) self-aggregation in solution, (ii) poor targeting and (iii) short half-life in vivo, due to the rapid uptake by the liver. Herein, to overcome these obstacles, we utilized polymeric micelles (PMs) based on the amphiphilic linear and branched block poly(ethylene oxide)–poly(propylene oxide) (PEO–PPO) copolymers (Pluronic® and Tetronic®) for ICG stabilization, vehicleization and to directionally target breast cancer tissues. Because of their singular properties, PMs offer several advantages such as the ability to modify their surfaces with a variety of receptor-targeting ligands and their nano-scale size, which is suitable for taking advantage of the enhanced permeability and retention (EPR) effect for cancer diagnosis. In this work, we prepared ICG within pristine F127 and T1307 and their glucosylated derivatives (F127-Glu and T1307-Glu, respectively). These systems have a sub-30 nm-nanosized hydrodynamic diameter (19–27 nm), moderate negative Z-potentials (until −10 mV), and satisfactory stability in water even after lyophilisation and reconstitution, at 25 and 37 °C, respectively. Particularly, ICG within T1307-Glu PMs displayed maximum solubility and excellent encapsulation efficiency (100%), with a potentially large in vivo uptake according to high specificity and efficacious capture in lymph nodes (LNs) and tumors. All the results presented in this work, indicate that ICG-loaded PMs can potentially be used as image probe agents for IGS, SLNB and breast cancer imaging.
Particularly, indocyanine green (ICG), an FDA-approved poorly water-soluble NIR fluorescent dye (<0.5 mg mL−1, pH 7.4), has been used for different diagnostic purposes, including IGS or SLNB, as a minimally invasive alternative to cancer identification.3 ICG presents a large number of advantages in clinical applications, such as the absorption and fluorescence NIR spectrum (between 700 and 900 nm), the high rates of detection and sensitivity in comparison with conventional methods, the low toxicity and the possibility of carrying out a SLNB without the need for a radioactive substance for solitary tumours. However, ICG presents important disadvantages in clinical administration: (i) self-aggregation in aqueous solution to form dimers, tetramers and oligomers (depending on the concentration used) that promote ICG fluorescence quenching and dramatically decrease the imaging-efficiency,4 (ii) instability in solution over time (>10 h) and upon exposure to light, (iii) poor active targeting and (iv) a short half-life in vivo (only 3–4 minutes when injected intravenously), with a fast uptake to the liver and strong protein binding.5,6 Likewise, NIR fluorophores derived from ICG, such as the hybrid nanocolloid albumin ICG-radionuclide,7,8 are currently the most commonly used standard probes for sentinel node mapping, e.g., technetium-99-metastable (99mTc).9–12
Polymeric micelles (PMs) are well-known nanosystems that have been used for solubilisation, stabilization and lengthening the bioavailability of different active biological molecules, such as pharmaceutical active ingredients, proteins and dyes, among others.13–15 PMs based on methoxypoly(ethylene glycol)-block-poly(D,L-lactide) (mPEG–PDLLA) and paclitaxel (Genexol-PM®, Samyang Biopharmaceuticals) were approved in South Korea, India and Vietnam in 2007.15 Genexol-PM® was later licensed by a US company, Sorrento Therapeutics Inc. and became Cynviloq™, which was approved by the U.S. Food and Drug Administration (FDA) in 2014 for the treatment of metastatic breast, ovarian, pancreatic and non-small cell lung cancers in humans.15
In particular, there has been a great increase in the use of pristine block copolymers, Pluronic® and Tetronic®, for tumour diagnosis and therapy, in response to their FDA approval.16–19 Notable features are their unique aqueous self-assembly properties and core–shell structure based on amphiphilic copolymers formed by one hydrophobic backbone of poly(propylene oxide) (PPO), flanked by hydrophilic poly(ethylene oxide) (PEO) chains,16–18 which can be advantageous when ICG is used for molecular cancer diagnosis. Chiefly, we have found that PMs preferentially accumulate in solid tumours and capitalize on their characteristics, such as the high vascularization, poor lymphatic clearance, and slow venous return, via the enhanced permeability and retention (EPR) effect that has been widely reported in different nanosystems.17–24
Doxorubicin within mixed PMs based on F127:L61 (SP1049C) is a nanoplatform that is currently in phase III clinical studies for the treatment of adenocarcinoma of the oesophagus and gastroesophageal junction.19 Among others, PMs based on Pluronic® F127 and Tetronic® T1307 exhibit hydrodynamic nanosizes between 15 and 30 nm at 37 °C and are formed by the spontaneous self-aggregation of amphiphilic block copolymers from the critical micellar concentration (CMC).17,18,21–24 Pluronic® F127 PMs have demonstrated satisfactory performance as agents for the encapsulation of ICG for the diagnosis of CT-26 colon carcinoma in tumour-bearing mice.3
It is important to mention that the encapsulation of ICG in other biodegradable micellar nanosystems has also been explored.25,26 Lymphoseek® (99mTc-Tilmanocept) is a relatively novel nanopolymeric system (∼7 nm in hydrodynamic size) that has been approved by the FDA as a lymphatic localization agent specific for solid tumours.9,27 This hybrid, approximately 16.7 kDa in molecular weight (MW), is composed of a polymeric chain of dextran covalently bound to multiple units of mannose9 and a 99mTc-diethylenetriaminepentaacetic (99mTc-DTPA) framework.27–29 There is high affinity between mannose and CD-206 receptors highly overexpressed on the surface of macrophages and dendritic cells.27 By firmly attaching to these mannose receptors, Lymphoseek® will accumulate in the lymphatic tissue in a few minutes and indicate the lymph nodes that drain the primary tumor.9
In this context, our group has worked in recent years on PMs coated with glucose-type residues, such as gluconolactone (Glu),18,21,22 which stabilizes the colloidal system due to the formation of multiple hydrogen bonds in the micellar corona. The advantage of this construct is that there is receptor-mediated internalization in the target cell that favours accumulation in the tumour due to increased cellular uptake at the expense of the exacerbated increase in the metabolism of these types of sugar in tumour cells.18,22–24,30,31
Likewise, it is noteworthy that our group has extensive experience with different conjugations, as well as characterization of the active targeting of molecules conjugated to various nanostructures.13,17,18,21,22,32–35 Some examples are (i) fluorescent boron-dipyrromethene (BODIPY)-loaded PMs to detect 4T1 breast cancer tumors,32 (ii) lactobionic acid (LA) PMs for lectin-like receptors (LLRs) overexpressed in many tissues and types of cells, such as hepatocytes, macrophages, and dendritic cells, among others,17,33 (iii) specific aptamers such as Sgc8-c PMs and liposomes for the PTK7 receptor, which is a biomarker in several types of cancer-like lymphomas,13 (iv) antibody-3F8 nanoparticles (NPs) to target the anti-GD2 receptor overexpressed in paediatric solid tumours,34 and (v) dermatan sulphate/chitosan NPs to target the CD44 receptor overexpressed in tissue endothelium,35 among other strategies. The aim of this research was to explore the efficiency of encapsulating ICG into PMs composed of pristine PEO–PPO block copolymers and their glycosylated derivatives. The physicochemical stability of freshly and freeze-dried ICG-loaded PMs was also examined, and they were evaluated as potential agents for the active and specific uptake by lymph nodes (LN) and additionally, in an induced 4T1 breast murine-tumour model. To the best of our knowledge, no LN uptake studies have been performed via an intradermal route using this type of ICG within PEO–PPO PMs and glucosylated derivatives, and therefore, this research is highly novel.
The results showed that the previously developed methodology of Glu-conjugation was very suitable and reproducible for T1307 glycosylation. There was little difference in the amount of incorporated lactone per mole of copolymer, resulting in 100% and 50% substitution for F127-Glu and T1307-Glu, respectively (ESI, Fig. S1A and B†).21 The T1307-Glu structure was confirmed by 1H NMR and 13C NMR (Fig. 1–3). Using T1307 CH3-signals at 1.02 ppm, as a reference of integration (276 hydrogens), we were able to quantify the proximate number of incorporated glucose-like moieties.
![]() | ||
Fig. 3 13C NMR spectra of T1307-Glu and pristine T1307 (inset) copolymers (20% w/v, in DMSO-d6, 298 K). |
Additionally, it was possible to identify the triplet at 2.31 ppm that integrates 4 protons corresponding to –CH2–CH2– of the ethylenediamine central core of T1307. In Fig. 2, the 1H NMR spectra of T1307-Glu and superimposed pristine T1307 are shown. In the region of the newly incorporated protons bonded to carbons from the glucose-like framework, between 3.30 and 4.50 ppm of the chemical shifts, at least three new groups of signals were observed. One probably corresponded to the esterified methylenes of T1307, which were displaced, and two corresponded to the methinic protons of CH–OH, which were a component of the sugar framework (4.42 ppm, 4.14, and 4.04 ppm, respectively, Fig. 2).
The integration showed that two molecules of gluconolactone were esterified per molecule of T1307, with 50% of the theoretical expected substitution (ESI, Fig. S1B†). T1307-Glu is a derivative with a molecular weight (∼19 kDa) higher than that of linear F127-Glu (∼13 kDa).21 Possibly, the signals belonging to the sugar moieties are less displaced due to the existence of a greater number of –CH units in the molecule, which overlap the electronegative effects of the incorporated –OH moieties. This results in greater difficulty through 1H NMR analysis in being able to demonstrate the effective conjugation of small molecules, such as glucose-like residues, to their terminal ends. Consequently, 13C NMR spectra (Fig. 3), through the signal near 175 ppm, confirmed the presence of the ester moieties.
Likewise, the product was characterized by FTIR spectroscopy. The pristine T1307 and glycosylated T1307-Glu copolymers showed the typical stretching vibrations of C–H and C–O–C of PEO chains and PPO blocks at 2881 and 1094 cm−1, respectively (Fig. 4A and B). Additionally, a new band at 1641 cm−1 that would correspond to the stretching vibration of the carbonyl groups (CO) of the newly generated ester function (T1307-Glu) (Fig. 4A), which the pristine T1307 does not present (Fig. 4B), was previously observed and reported in the F127-Glu characterization.21
![]() | ||
Fig. 4 FTIR analysis of lyophilised (A) T1307-Glu (red line) and (B) T1307 (black line) copolymers, at 278 K. |
The CMC values obtained by DLS of the glycosylated copolymers were studied to analyse the capacity for spontaneous self-assembly and physical stability of the PMs in Milli-Q water and in PBS, at 25 and 37 °C (Table 1). There were lower CMC values for the novel T1307-Glu copolymer as compared to the pristine copolymer (T1307), decreasing with temperature in water (0.012 and 0.008% w/v, at 25 and 37 °C) and PBS (0.025 and 0.010% w/v, at 25 and 37 °C) (Table 1). Similarly, we previously reported lower CMC values for the F127-Glu derivative as compared to its pristine counterpart (Table 1).21,22 The CMC value for pristine T1307 was lower than that for pristine F127 in water (0.025% w/v, at 25 and 37 °C) and PBS (0.100% and 0.050% w/v for PBS, at 25 and 37 °C, respectively) (Table 1), which suggests a tendency towards more efficient micellar self-formation for the branched four-arm derivative as compared to the linear derivative. This is consistent with our previous studies with other poloxamers and poloxamines.17,18,21,22,32,33 The CMC values were higher in PBS than in water at both temperatures (Table 1) for all pristine and glycosylated derivatives, except for the F127-Glu derivative, which displayed a slightly more efficient stability and self-assembly in PBS than in water (Table 1).
The results obtained after glycosylation are very relevant because the CMC reductions for glycosylated copolymers (F127-Glu and T1307-Glu), compared to the original pristine copolymers (F127 and T1307) and under all conditions (Table 1), indicate an increase in the tendency to micellize through physical stabilization from the sugar residue on the corona. Therefore, there would be biologically relevant implications for this occurrence due to the greater stability of PMs under conditions of high dilution, such as those that occur after IV and ID administration. Finally, it is important to highlight that this biological fact was demonstrated with the use of F127-Glu PMs in our previously published studies.18,21,22
Copolymer | ICG (μg mL−1) (±S.D.) | EEa (%) (±S.D.) |
D
h![]() |
% Int. (±S.D.) | PDIc (±S.D.) | Z-Potd (mV) (±S.D.) |
---|---|---|---|---|---|---|
a The encapsulation efficiency (EE) was obtained after taking into account the amount of ICG encapsulated into PMs before and after clarifying filtration (with 0.22 μm filters), at 25 °C. b Hydrodynamic diameter (Dh) of PMs/ICG, at 37 °C by DLS and expressed by % Int. (intensity%). c Polydispersity index (PDI) of ICG-loaded PMs, at 37 °C by DLS. d Zeta-potential (Z-Pot) of PMs/ICG, at 25 °C by DLS. | ||||||
F127/ICG | 37 (0.5) | 10 (0.03) | 26.7 (4.2) | 100 (0.0) | 0.720 (0.120) | −4.0 (0.2) |
F127-Glu/ICG | 209 (5.1) | 56 (1.00) | 21.8 (5.7) | 100 (0.0) | 0.659 (0.232) | −5.2 (0.1) |
T1307/ICG | 375 (0.5) | 100 (0.00) | 18.5 (2.9) | 100 (0.0) | 0.294 (0.094) | −5.9 (0.9) |
T1307-Glu/ICG | 375 (1.0) | 100 (0.00) | 22.1 (5.5) | 100 (0.0) | 0.384 (0.043) | −9.6 (0.7) |
These results revealed that there was potential for the core size of pristine PMs (F127) and glycosylated PMs (F127-Glu) to have improperly interacted with the amphiphilic and relatively large ICG molecule. This would have drastically reduced its intrinsic solubility in aqueous dispersion, while the ICG–core interaction of the T1307 derivatives resulted in optimal solubility.
The lyophilised ICG-loaded PMs resulted in stable particle size and Z-potential after reconstitution in Milli-Q water (Fig. 5 and Table 2). The values for Dh, PDI and Z-potential before (for fresh PMs/ICG) and after lyophilisation and reconstitution were similar (data not shown). According to all the results obtained, the strongest performance for further in vivo studies would be expected with the use of T1307-Glu/ICG PMs, especially due to its EE% for ICG (100%) and active sugar targeting.
![]() | ||
Fig. 6 TEM image acquisition of free (A) T1307-Glu PMs and (B) T1307-Glu/ICG PMs. Scale bar: 0.2 μm. Magnification: 30![]() |
There would be a great advantage to using T1307-Glu/ICG PMs for real-time IGS because the SLN commitment could be analysed, and the progression of the malignant disease could be studied with greater precision. It is important to note that free ICG remained localized at the point of the injection site for 2 h post-ID (ESI, Fig. S3†). These results are also consistent due to the potential overexpression of GLUT-1 receptors in macrophages and various tumours.18,21–24,36
We propose these types of active targeting nanosystems to minimize the time required for obtaining images, to avoid the phenomena of self-aggregation of ICG, and to reduce the necessary concentration of ICG required for these procedures. We also focused on designing and developing less invasive and expensive therapies with greater personalization for routine medical studies.37,38 Equally important is the reduction of unnecessary biopsies, which would manifest itself in the reduction in the number of patients with pathologies associated with surgery, such as lymphedema.9,27–29
Another point of great relevance is that if we consider that the 99mTc-nanocolloid of albumin (∼80 nm in size) can generate hypersensitivity reactions and secondary effects in response to exposure to ionizing radiation, then these types of nanovehicles would represent an advantage because there is no toxicity at the used concentrations.18,37 It is important to mention that we recently studied the acute toxicity for these PEO–PPO PMs, through the “Up and Down test studies,” according to the Organization for Economic Cooperation and Development (OECD) recommendations and focusing on the study of mutagenicity and in vivo lethal doses (in vivo LD50) of these PMs encapsulating a novel antineoplastic agent.18,45 However, one of the most important advantages of PMs is that only minimal administration would be required in humans to obtain the necessary diagnostic information.
Finally, we proceeded to analyse the uptake of PMs/ICG by porting 4T1 breast tumours into BALB/c mice. The results revealed an enhanced circulation time and a satisfactory performance of T1307-Glu/ICG PMs at 24 h, with a selective uptake of the 4T1 implanted tumour (Fig. 8B) that was most likely due to the capacity for binding and internalization by the GLUT-1 receptor,18,21–24,39,40 which is overexpressed in different solid tumors.37 Particularly, we have been exploring the different parameters in this tumour model with different PM formulations.18,22,32
The present in vivo results, in accordance with those we previously obtained in ex vivo studies of PMs/curcumin,22 indicated that there was selective uptake for these nanovehicles in a breast cancer tumour model, and it could be explored in other models that overexpressed these types of GLUT transporters. The tumour capture was more competent for T1307-Glu/ICG PMs (three times, Fig. 8B and C) as compared to the control treated with free-ICG (Fig. 8A). Additionally, no systemic toxicity effects were observed after our PMs were administered to animals.18,22
Based on all the results displayed in the 4T1 breast tumour model and strongly evidenced by the LNs of healthy rats, we suggest that we discovered for the first time a potential candidate for an ICG-based image agent deployed in glycosylated polymeric micelles and employing PEO–PPO with active targeting capacity.41–43
The flask was placed in a microwave oven (Itedo™, 2.45 GHz radiation frequency, potency 900 W; Shanghai, China). The reaction was carried out by microwave irradiation according to (i) two cycles of 5 min at 30 W of power and (ii) one cycle of 10 min at 10 W of power. The total reaction time was 20 min. The reaction mixtures obtained for each case were diluted in Milli-Q water (1:
2) at room temperature and dialyzed (regenerated cellulose dialysis membranes; molecular weight cut-off of 3500 g mol−1 for F127 and F127-Glu21,22 and 12
500 g mol−1 for T1307 and T1307-Glu, Spectra/Por® 3 nominal flat width of 45 mm, diameter of 29 mm and volume/length ratio of 6.4 mL cm−1; Spectrum Laboratories, Inc., Rancho Dominguez, CA, USA) against Milli-Q water for 3 days with frequent exchanges of the dialysis medium to remove free Glu residues and oligomeric subproducts. Micelle dispersions were filtered (0.22 μm, Filter Discs Qual., Grade 289, Sartorius AG, Goettingen, Germany) and frozen at −20 °C for 48 h. Finally, the pristine and glycosylated PMs were freeze-dried (Lyophilizer L05, F.I.C., Scientific Instrumental Manufacturing, Buenos Aires, Argentina) at a condenser temperature of −45 °C, with 30 bar pressure for 72 h. The product was stored at −20 °C until use.
The FTIR spectra were obtained with a Nicolet 380 spectrometer (Avatar combination kit, Smart Multi-Bounce HATR with ZnSe 458 crystal reflection, Is50 FTIR, Thermo Scientific, Madison, WI, USA) in the range of 4000 and 400 cm−1 (32 scans, spectral resolution of 4 cm−1). The solid samples were lyophilized (T1307 and T1307-Glu) and mounted on an ATR metal-crystal plate. The spectra were obtained with OMNIC 8 (Thermo-Scientific) spectrum software and were subsequently analyzed by processing with Origin 8 software for spectral elaboration. It should be noted that we previously reported the characterization of the F127-Glu derivative.18,21,22
The intensity of the scattered light and derived count rate (DCR) measurements were carried out at a scattering angle of 173° and plotted expressed in kilocounts per second vs. copolymer concentration (in % w/v). The data for each single specimen were the result of at least four replicas of three independent fresh solutions. The micellization was observed as a sharp increase in the scattered light intensity. The intersection between the two different straight lines corresponded to the CMC.
Five experiments with ICG-loaded PMs were performed, and the data are expressed as the mean ± standard deviation. Dh, PDI and Z-Pot were determined after the lyophilisation and reconstitution processes in the corresponding media. The Dh and critical quality parameters of the micellar products were studied by DLS, before freeze-drying and reconstitution to verify the stability and integrity of the PMs before and after the processes.
Glycosylated PMs, particularly T1307-Glu PMs, displayed the maximum solubility of ICG and EE of 100%. Additionally, T1307-Glu PMs have a small and monodisperse size (sub-30 nm) distribution that may result in a potential EPR effect, with satisfactory stability in fresh aqueous media and after lyophilisation and reconstitution for at least 24 h. Furthermore, because of the active surface glycosylation of PMs, they are capable of greater uptake through the GLUT-1 receptors overexpressed in macrophages and in 4T1 murine breast cancer tumours. The overall results presented in this work indicate the potential use of ICG-loaded PMs as image probe agents for IGS, SLNB, and breast cancer diagnostic imaging.
Footnote |
† Electronic supplementary information (ESI) available: Fig. S1–S3. See DOI: https://doi.org/10.1039/d3pm00053b |
This journal is © The Royal Society of Chemistry 2024 |