Martina
Rimmele
a,
Adam V.
Marsh
b,
Charlotte L.
Rapley
a,
Ashraf
Al-Amoudi
c and
Martin
Heeney
*ab
aDepartment of Chemistry and Centre for Processable Electronics, Imperial College London, London, W12 0BZ, UK. E-mail: m.heeney@imperial.ac.uk; martin.heeney@kaust.edu.sa
bKing Abdullah University of Science and Technology (KAUST), KAUST Solar Centre (KSC), Physical Sciences and Engineering Division (PSE), Thuwal, 23955-6900 Saudi Arabia
cKing Abdullah University of Science and Technology (KAUST), Imaging and Characterization Core Labs, Electron Microscopy Lab, Thuwal, 23955-6900 Saudi Arabia
First published on 28th May 2024
The preparation of graft copolymers remains a challenge, especially for conjugated materials, due to the limited number of reactions available for backbone modification. Herein, we report a reliable method to conjugated graft copolymers (also known as rod-graft-coil copolymers) starting from different well studied polymers in a one-step post-polymerisation reaction. The starting polymers all contain a commonly used benzo[c][1,2,5]thiadiazole unit, which includes a fluorine atom as a functional handle for replacement via a nucleophilic aromatic substitution (SNAr) reaction. We functionalised the polymers in a post-polymerisation approach with secondary thiol-terminated polystyrene (PS), readily available from the RAFT polymerisation. Furthermore, we prepared stable, spherical, emissive nanoparticles from the resulting graft copolymers as shown by dynamic light scattering (DLS) and transmission electron microscopy (TEM). The optical properties of the parent and the graft copolymers were studied in solution and solid state, as well as in nanoparticles (NPs). PLQY studies revealed, that the emission was enhanced upon grafting of PS in the NPs. This approach offers the preparation of graft copolymers in one additional step after polymerisation only, and moreover enhances the emissive properties of the resulting graft copolymers in the solid state which is promising in the field of biologically benign fluorescent nanoprobes.
Methods of synthesising graft polymers can be divided into three processes: grafting-from, grafting-through, and grafting-onto. Grafting-from involves attaching a polymerisable monomer or initiator to the parent polymer's backbone, followed by subsequent polymerisation; grafting-through uses a preformed polymer with a reactive end group for subsequent polymerisation (sometimes called the macromonomer approach); while grafting-onto is the only method that bonds pre-formed polymer chains onto the parent polymer's surface. The latter has a distinct advantage over the other processes in that it allows for the incorporation of well-defined polymer segments, resulting in precise control over the grafting density and distribution. Such grafting-onto strategies have found recent application in the field of conjugated polymers.1–4
Conjugated polymers have been widely studied due to their unique properties, which make them promising material in various applications, such as organic photovoltaics (OPVs),5,6 organic light emitting diodes (OLEDs),7 and organic photodetectors (OPDs),8 amongst others. Their attraction in these applications stems from their highly tunable electronic and optical properties, low-cost processing, flexibility, low weight and biocompatibility.9,10 Despite the enormous interest in conjugated polymers, reports of graft copolymers, in which non-conjugated polymers are attached to a conjugated backbone (sometimes called rod-coil graft copolymers) are rare.11–15 The alternative arrangement, in which conjugated polymers are grafted to a non-conjugated polymer is also uncommon.16 Often this latter scenario uses the grafting through or macromonomer approach, in which a reactive end-group on a conjugated polymer is subsequently polymerised by techniques such as controlled radical polymerisation. Many reports utilise poly(3-hexyl)thiophene (P3HT) as the macromonomer, since it can be prepared with reactive end-groups via the well-controlled catalyst transfer polymerisation.1,17
In the case of conjugated polymers with non-conjugated grafts, the ‘grafting to’ approach has been the most explored since the advent of click chemistry.18 Thus, conjugated polymers can be prepared with sidechains containing reactive functionality, most often azide or alkyne groups, and non-conjugated polymers with complimentary reactive ends attached. For example, P3HT containing an alkylazide sidechain can be grafted with poly(vinylpyridine) containing an alkyne end-group under copper-catalyzed azide–alkyne cycloaddition (CuAAC) conditions.19 The resulting graft was used as a compatibiliser to improve the thermal stability of bulk-heterojunction OPVs. Similar approaches were used to graft the same polymer to an emissive polyfluorene backbone,20 or graft poly(ethyleneglycol) (PEG) to a low band gap polymer.21 One interesting application has been the grafting of PEG and poly(methyl methacrylate) (PMMA) to an azide functionalised P3HT.22 Nanoparticles (NPs) of all three polymers were formed, as potential low toxicity, fluorescent nanoprobes.23,24 Whilst the parent P3HT based NPs were poorly emissive, due to the formation of aggregates that quenched excitons in the aggregated state, NPs of the grafts with PEG or PMMA demonstrated up to two orders of magnitude higher photoluminescent quantum yields.
Whilst these reports have demonstrated the utility of the graft approach, they can be complex to implement synthetically. For example, in the case of P3HT grafts, the polythiophene is first prepared with alkylbromide sidechains, followed by a post-polymerisation reaction to convert the alkylbromide to azide, and a second post-polymerisation reaction to couple the azide to alkyne terminated polymer (which also need to be prepared). Two post-polymerisation steps increases the chance to introduce undesired defects and miscouplings. Thus new, simpler synthetic approaches to such rod-coil graft copolymers are highly desirable.25
One potential way for the functionalisation of conjugated polymer backbones is a nucleophilic aromatic substitution (SNAr) reaction directly on the conjugated backbone. Our group has previously demonstrated the direct functionalisation of conjugated polymers by halide displacement from fluorinated, electron deficient monomers such as benzo[c][1,2,5]thiadiazole units within a conjugated polymer backbone. A variety of primary thiols and alcohols were used as nucleophiles to substitute the backbone in quantitative or near-quantitative yield.26,27 Promisingly, graft copolymers could be readily prepared by the reaction of PEG (up to 10000 g mol−1) with a hydroxyl end-group. This graft-onto strategy induced remarkable changes in the properties of the polymers, such as enabling the PEGylated poly(dioctylfluorene-co-benzothiadiazole) (F8BT-PEG) to dissolve in protic solvents including water.28 F8BT-PEG derivatives have also been shown to form in vivo stable semiconducting polymer nanoparticles (NPs) through simple nanoprecipitation techniques, with potential applications in cancer theranostics where the conjugated polymer is encapsulated within the benign PEG host material.29 Similar reactions have also been reported on an electron deficient perfluorinated benzene within conjugated polymer systems.30–32 Given the simplicity of this approach, we were keen to investigate if other graft copolymers could be prepared, for example by the coupling of secondary thiols to the conjugated backbone. Such thiols are readily available in well-controlled manner via the reversible addition and fragmentation chain transfer (RAFT) technique, followed by the facile conversion of the thiocarbonylthio end-group to a secondary thiol.33,34 Given the large variety of such RAFT copolymers that can be readily prepared from different monomers, direct coupling of the secondary thiol end-group to the conjugated backbone offers a potentially simple route to a range of rod-coil copolymers. However, given the additional steric hindrance associated with a secondary thiol end-group, its ability to participate in SNAr onto the conjugated backbone was unclear at the outset of this work.
Herein, we present an efficient approach for the preparation of polystyrene-grafted conjugated copolymers using a SNAr based method. The method couples a secondary thiol-terminated polystyrene to three different conjugated backbones with different graft densities. Moreover, we demonstrate the subsequent preparation of stable, uniform, spherical, and emissive NPs from these grafted polymers using a nanoprecipitation method, with no requirement to add additional surfactants or other additives. Significant suppression of aggregation-caused quenching (ACQ) in aggregated states was observed upon grafting, leading to an increased photoluminescence quantum yield (PLQY) for the grafted, relative to the un-grafted, polymers with promise for application as fluorescent probes in biological systems.
All three conjugated polymers were purified using Soxhlet extraction with methanol, acetone and hexane to remove lower molecular weight fractions and finally extracted in chloroform and precipitated. Their molecular weights were analysed by gel permeation chromatography (GPC) in 1,2,4-trichlorobenzene (1,2,4-TCB) at 150 °C versus polystyrene standards (see Table 1 and Fig. S.1†). All polymers exhibited monomodal distributions, with molecular weight comparable to those previously reported (F8fBT: Mn = 44.8 kDa; IDTfBT: Mn = 15.9 kDa; FO6-T: Mn = 24.4 kDa).
Sample | M n (kDa) | M w (kDa) | Đ |
---|---|---|---|
F8fBT | 44.8 | 133 | 2.99 |
PS-F8BT | 98.2 | 222 | 2.26 |
IDTfBT | 15.9 | 35.8 | 2.26 |
PS-IDTBT | 34.4 | 51.0 | 1.48 |
FO6-T | 24.4 | 69.4 | 2.85 |
PS-FO6-T | 40.2 | 73.7 | 1.83 |
To date, only primary thiols have been utilised in post-polymerisation SNAr reactions. To establish that secondary thiols could undergo SNAr smoothly, we initially investigated the reaction of 2-butanethiol with F8fBT. After heating in the microwave for 1.5 hours in presence of potassium carbonate, gratifyingly the resulting polymer 2S-F8BT was found to have undergone complete fluorine substitution. We then moved onto the more challenging coupling of the thiol terminated PS (PS-SH), using a narrow dispersity (Đ of ≤1.1) sample with a Mn of 5000 g mol−1. As discussed above, a wide range of thiol terminated polymers can be readily prepared by RAFT techniques,34 although in this case commercially available PS-SH was chosen for convenience. An additional attraction of the polystyrene grafts was that simple blending of fluorescent conjugated polymers with PS has been shown to improve the emissive performance in OLED devices, due to a reduction in trap density.43–45 Moreover, while it can be difficult to ensure good mixing of polymer blends due to the low entropy of mixing polymers, we envisioned that grafting PS to conjugated polymer backbones would ensure good miscibility.
For each conjugated polymer, we reacted 1.2 equivalents of PS-SH in the presence of excess K2CO3 under heating at 120 °C for 3 days (see Scheme 1). Note that whilst the molar excess, based on the repeat unit mass, is small, the mass difference of each reagent is large (see ESI†). The crude products were precipitated in methanol and purified using Soxhlet extraction with methanol and acetone (24 h each) to remove excess thiol, and finally extracted into chloroform. The resulting polymers PS-F8BT, PS-IDTBT and PS-FO6-T were then characterised with GPC and NMR spectroscopy.
Scheme 1 Synthesis of the PS-grafted target polymers PS-F8BT, PS-IDTBT, and PS-FO6-T from the fluorinated starting polymers via a SNAr approach. |
The molecular weights of the graft copolymers were analysed using GPC in 1,2,4-TCB (Table 1, with more details in the ESI†). While PS-IDTBT exhibited a monomodal peak, both PS-F8BT and PS-FO6-T exhibited traces of unreacted PS-SH (and is oxidised dimer PS-SS-PS), which was incompletely removed by washing due to the large physical excess (Fig. S.2b†). The excess PS-SH could be removed from PS-FO6-T by preparative GPC (Fig. S.3†). Whilst the GPC confirmed an increase in weight, a higher value might have been expected given the size of the graft. Here we note that GPC analysis of graft copolymers against linear polystyrene standards is unrepresentative, given that the more densely packed conformations of grafts typically give smaller hydrodynamic radii compared to linear polymers. Similar observations have been observed in P3HT graft copolymers.22
1H-NMR of the grafts showed the occurrence of new signals corresponding to the PS. However, as the ratio of grafted PS to the respective backbone polymers is high, the backbone conjugated polymer signals are largely not visible in the 1H-NMR spectra. Additional proof of complete fluorine displacement comes from the absence of a signal in the 19F-NMR spectra of the three graft polymers. To further confirm the grafting of the PS to the conjugated polymer backbones, we used diffusion ordered NMR spectroscopy (DOSY), comparing the graft copolymers to a blend of both polymers (Fig. S11–13†). The 2D DOSY spectra plot chemical shift versus diffusion coefficients for individual species and are therefore able to determine the number of polymeric species present in a sample. For the samples with F8fBT, IDTfBT and FO6-T blended with PS-SH we observed two diffusion peaks, indicating that there are two separate polymers diffusing at different rates in each sample. For the graft copolymers the DOSY spectra display a single diffusion peak in all cases, providing strong evidence for the coupling of the PS to the conjugated backbone. The diffusion coefficient decreased compared to the starting polymers, due to the higher molecular weight of the grafted polymers.46
Further evidence for the success of the grafting approach was obtained by study of the material properties of grafted and parent polymers. Contact angle measurements using solvents of varying polarity (water, ethylene glycol and benzylic alcohol) showed that, upon grafting of PS, the wetting of the polymer films changed markedly (Table S.1†). Due to the decrease in the polarity that stems from the functionalisation with apolar PS, the contact angles decreased for ethylene glycol and benzylic alcohol. The thermal properties of the parent polymers and the respective graft copolymers were also studied, using thermogravimetric analysis (TGA) (Fig. S.14†) and differential scanning calorimetry (DSC) (Fig. S.15 and S.16†). TGA revealed good stability for the graft copolymers up to 328 °C for PS-FO6-T, 344 °C for PS-IDTBT and 337 °C for PS-F8BT, at which point a 5% weight loss was observed (Td). Comparing to the Td of the parent polymers, no clear trend in terms of changes in this metric were observed; for F8fBT, the Td was determined to be 328 °C, hence the Td was increased upon grafting, with similar results obtained for FO6-T (Td of 305 °C at 5% weight loss, slightly lower than the graft copolymer), but in the case of IDTfBT, the Td was found to be 403 °C, corresponding to a lowering of the Td upon grafting with PS.
DSC curves showed a glass transition temperature (Tg; determined using the derivative of the heat flow) of 61 °C for PS-F8BT, 59 °C for PS-IDTBT, and 58 °C for PS-FO6-T. We attribute this transition to the PS grafts, since none of the parent polymers show any features in the DSC traces up to 300 °C. This is in agreement with previous reports for F8fBT and FO6-T, as well as non-fluorinated IDTBT, and is generally characteristic for rigid rod conjugated polymers.38,47 The observed Tg transitions for graft copolymers are lower compared to the literature value of around 80 °C for pure PS samples with a Mn around 5000 g mol−1.48 Overall, these data collectively demonstrate the efficiency of the SNAr-based grafting approach, and the ability of PS-grafting to tune the material properties of conjugated polymers.
To investigate the stability of the NPs over time, NP suspensions were prepared from the graft copolymers and analysed over periods of up to 14 days. The DLS results showed that the particles were stable in suspension over these time periods, with no observed changes in the size distribution (Fig. S.17a–c†). These results were consistent with the stability of the parent polymer nanoparticles, which also showed no change of Z-average upon aging (Fig. S.17d†).
To study the shape and confirm the size of the NPs, cryo-TEM experiments were performed. The selected images in Fig. 1c demonstrate the overall trend in the cryo-TEM observations that the particle sizes were indeed around 50 nm in the case of all grafted polymers. Furthermore, the images show that spherical, uniform, and morphologically homogeneous particles were prepared with this method.
For PS-IDTBT a significant blue shift of the main absorption peak can be observed, from 657 nm for IDTfBT to 609 nm for PS-IDTBT, along with a change in the relative intensities for the lower energy ICT band compared to the higher energy band (Fig. 2b). The widening of the polymer band gap and reduction in ICT intensity has previously been attributed to steric backbone twisting effect due to the presence of sulfur from the thioether group.27,50 Similar trends were observed for PS-FO6-T (Fig. 2c), although here the blue shift was larger, possibly due to a more pronounced steric effect due to the presence of two substituents on the BT group. The absence of a shift for F8fBT suggests the conjugated backbone is already twisted, as previously noted,35–38 relative to the more planar IDTFBT and FO6-T. The photoluminescence spectra of the grafts and the blends are shown in Fig. 2, and results summarised in Table 2. For PS-IDTBT there was no shift of the λPL,max (in solution) after the grafting, for PS-F8BT there was a small shift of 17 nm upon grafting (in agreement with the previous reports on thioether grafting), and for PS-FO6-T was a significant shift of 54 nm after grafting. The Stokes shifts of all polymers increased upon functionalisation with PS, with values of 0.494, 0.299, and 0.467 eV for PS-F8BT, PS-IDTBT, and PS-FO6-T, respectively. The observed increases in Stokes shift for the functionalised polymers can be attributed to a combination of steric effects, principally from the replacement of fluorine with the significantly larger sulfur, as well as the change from an electron withdrawing group to a slightly electron donating group.27
λ abs,max (nm) | λ onset (nm) | λ PL,max (nm) | Stokes Shift (eV) | E g,opta (eV) | |||
---|---|---|---|---|---|---|---|
Polymer | Sol. | Film | Sol. | Film | Sol. | Sol. | Sol. |
a Estimated from the onset of absorption from the measured UV-vis spectra where E = hc/λ. | |||||||
F8fBT | 319, 441 | 455 | 486 | 514 | 521 | 0.432 | 2.55 |
PS-F8BT | 322, 443 | 326 | 486 | 504 | 538 | 0.494 | 2.55 |
IDTfBT | 657 | 680 | 712 | 722 | 713 | 0.148 | 1.74 |
PS-IDTBT | 609 | 629 | 699 | 712 | 714 | 0.299 | 1.77 |
FO6-T | 625 | 665 | 723 | 737 | 713 | 0.245 | 1.72 |
PS-FO6-T | 528 | 651 | 633 | 785 | 659 | 0.467 | 1.96 |
The graft copolymers were further studied in thin films on glass substrates spun cast from CHCl3 solutions (Fig. 2). For all PS-graft copolymers, the absorption maxima were red shifted compared to solution maxima, which is commonly observed for conjugated polymers and can be attributed to more planar structures in the solid state.51 The shapes of the curves did not, however, change significantly, although some broadening can be observed. Interestingly, the optical band gap (calculated from the onset of the absorption from the solution) for F8fBT and IDTfBT-based polymers showed no significant change upon grafting of the PS. In the case of FO6-T however, a large change was observed, increasing the gap significantly from 1.72 eV to 1.96 eV, which we attribute to significant twisting of the backbone upon grafting of the PS likely due to the higher grafting density.
The optical properties of the NPs were studied using UV-vis absorption and PL spectroscopy and compared to NPs prepared from the parent polymers, with the results shown in Fig. 3 and Table 3. One commonality between them all, apart from broadening of the signals, is the weakened absorption upon grafting, which can be explained by the decreased percentage of conjugated polymer in the samples. From the PL spectra, strong emission of PS-F8BT particles was noted (see Fig. 3d), whereas the emission for PS-IDTBT and PS-FO6-T NPs was found to be moderate (Fig. 3e and f). Interestingly, however, the emission intensity increased upon grafting in the cases of PS-F8BT and PS-FO6-T, while for PS-IDTBT NPs it was found to be similar to the parent polymer NPs.
Sample | λ abs,max (nm) | λ PL,max (nm) |
---|---|---|
F8fBT | 320 | 517 |
PS-F8BT | 321 | 522 |
IDTfBT | 675 | 707 |
PS-IDTBT | 625 | 710 |
FO6-T | 611 | 718 |
PS-FO6-T | 322 | 651 |
The CIE colour spaces of the three graft copolymer NP suspensions are shown in the ESI (Fig. S.18–20†). PS-F8BT shows yellow-green emission (x = 0.41, y = 0.56, CIE 1931), while for PS-IDTBT and PS-FO6-T NPs we observed emission mainly in the near-infrared (NIR) region of the solar spectrum, and hence the coordinates are located at the border of the colour plots (pictures of the grafted NP suspensions are shown in Fig. S.21†).
The photoluminescence quantum efficiency (PLQY) of the parent and the graft copolymers in chloroform solutions, thin films and NP suspensions were investigated and the results are summarised in Table 4. For the graft copolymers PS-F8BT, PS-IDTBT and PS-FO6-T we observed that the PLQYs in solution were 31%, 20% and 9% respectively. If these are compared to the solution PLQY of the parent polymers, the grafting has a different effect in all three cases. F8fBT shows a significantly higher PLQY compared to the graft, whereas in the case of FO6-T the grafting has a positive effect on the PLQY and for IDTfBT no changes are observed. In the aggregated states, film and NP, the PLQY decreases compared to the solutions which can be ascribed to aggregation-caused quenching (ACQ), a well-known effect for planar aromatic structures due to their inherently strong tendency to π–π stacking.52 Gratifyingly, ACQ is moderately suppressed upon grafting in the condensed states, indicated by an increase of the PLQY for graft copolymers in the films and NPs (with the exception of the films of FO6-T and PS-FO6-T, where the signals were too low to be accurately measured). This demonstrates that the emission of the polymers can be significantly enhanced by grafting of PS onto the backbones.
Sample | Solution PLQY (%) | NP PLQY (%) | Film PLQY (%) |
---|---|---|---|
F8fBT | 54 | 8 | 22 |
PS-F8BT | 31 | 20 | 27 |
IDTBT | 20 | <1 | <1 |
PS-IDTBT | 20 | 3 | 7 |
FO6-T | 2 | <1 | n.m. |
PS-FO6T | 9 | 1 | n.m. |
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4py00492b |
This journal is © The Royal Society of Chemistry 2024 |